Javascript must be enabled to continue!
Justification and Optimization Principles of ALARA in Pediatric CT at a Teaching Hospital in Ethiopia
View through CrossRef
BACKGROUND: Radiation from CT (computerized tomography), poses risk of radiation associated cancer. Studies indicate a cumulative dose of 50mGy triples the risk of leukemia and a dose of 60mGy triples the risk of brain tumors in children. This study aimed to assess the application of “Justification and Optimization Principles of ALARA (As Low As Reasonably Achievable)” in pediatric CT.METHOD: A prospective cross-sectional study was conducted from December 2017 to July 2018 G.C at Tikur Anbessa Specialized Hospital. CT request forms were reviewed. All pediatric patients listed for CT were included. The collected data were analyzed using SPSS version 25.RESULTS: Four hundred and twenty nine CT requests were reviewed, 246 (57.3%) were males and 183(42.7%) were females; 52(12.1%) were less than 1 year old, 153(35.7%) between 1 to 5 years, 113(26.3%) between 5 to 10 years and 111(25.8%) 10 to 14 years old. On the other hand, 28(6.5%) scan requests were rejected based on the ALARA justification principle, and from these, in 11(39.2%) MRI was recommended instead of CT, in 6(21.42%) US was recommended. Review of previous CT helped to reject 4(14.28%). Review of prior chest radiographs helped in rejecting 2(7.14%) requests. For 5(17.8%) and 19(4.4%), requests were optimized by applying principles of optimization to reduce received dose from CT.CONCLUSION: Overall, 47(11%) patients were protected from unnecessary radiation exposure by applying the principles of ALARA. The use of other alternating imaging modalities is vital in pediatric patients who are more radiosensitive and have longer time to manifest radiation induced injury.
African Journals Online (AJOL)
Title: Justification and Optimization Principles of ALARA in Pediatric CT at a Teaching Hospital in Ethiopia
Description:
BACKGROUND: Radiation from CT (computerized tomography), poses risk of radiation associated cancer.
Studies indicate a cumulative dose of 50mGy triples the risk of leukemia and a dose of 60mGy triples the risk of brain tumors in children.
This study aimed to assess the application of “Justification and Optimization Principles of ALARA (As Low As Reasonably Achievable)” in pediatric CT.
METHOD: A prospective cross-sectional study was conducted from December 2017 to July 2018 G.
C at Tikur Anbessa Specialized Hospital.
CT request forms were reviewed.
All pediatric patients listed for CT were included.
The collected data were analyzed using SPSS version 25.
RESULTS: Four hundred and twenty nine CT requests were reviewed, 246 (57.
3%) were males and 183(42.
7%) were females; 52(12.
1%) were less than 1 year old, 153(35.
7%) between 1 to 5 years, 113(26.
3%) between 5 to 10 years and 111(25.
8%) 10 to 14 years old.
On the other hand, 28(6.
5%) scan requests were rejected based on the ALARA justification principle, and from these, in 11(39.
2%) MRI was recommended instead of CT, in 6(21.
42%) US was recommended.
Review of previous CT helped to reject 4(14.
28%).
Review of prior chest radiographs helped in rejecting 2(7.
14%) requests.
For 5(17.
8%) and 19(4.
4%), requests were optimized by applying principles of optimization to reduce received dose from CT.
CONCLUSION: Overall, 47(11%) patients were protected from unnecessary radiation exposure by applying the principles of ALARA.
The use of other alternating imaging modalities is vital in pediatric patients who are more radiosensitive and have longer time to manifest radiation induced injury.
Related Results
A short Review of the ALARA Principle in Radiation Protection
A short Review of the ALARA Principle in Radiation Protection
Any activity involving radiation should be planned and conducted in such a way that the exposures to individuals are optimally low, taking into consideration the economic and cost ...
Diplomatic Claims (Eritrea v. Ethiopia), Eritrea ' s Claim 20/Ethiopia ' s Claim 8, Partial Awards; Economic Loss Throughout Ethiopia (Ethiopia v. Eritrea), Ethiopia ' s Claim 7, Partial Award; Jus ad Bellum (Ethiopia v. Eritrea), Ethiopia ' s Claims 1-8,
Diplomatic Claims (Eritrea v. Ethiopia), Eritrea ' s Claim 20/Ethiopia ' s Claim 8, Partial Awards; Economic Loss Throughout Ethiopia (Ethiopia v. Eritrea), Ethiopia ' s Claim 7, Partial Award; Jus ad Bellum (Ethiopia v. Eritrea), Ethiopia ' s Claims 1-8,
Diplomatic Claims (Eritrea v. Ethiopia), Eritrea's Claim 20/Ethiopia's Claim 8, Partial Awards. At <http://www.pca-cpa.org>.Eritrea Ethiopia Claims Commission, December 19, 2...
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
BACKGROUND:
A workforce analysis was conducted to predict whether the projected future supply of pediatric anesthesiologists is balanced with the requirements o...
Synthesis of the European ALARA network 18th workshop ‘ALARA for decommissioning and site remediation’
Synthesis of the European ALARA network 18th workshop ‘ALARA for decommissioning and site remediation’
Abstract
The European ALARA Network regularly organises workshops on topical issues in radiation protection. The topic of the 18th workshop was ‘ALARA for Decommi...
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
BACKGROUND:
The geographic relationship between pediatric anesthesiologists and the pediatric population has potentially important clinical and policy implications. In ...
Developing Residents as Teachers: Process and Content
Developing Residents as Teachers: Process and Content
These data characterize and illuminate an analysis of experiences about teaching during each year of a pediatric residency training program in a tertiary care center. The curriculu...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Patient X-ray Exposure and ALARA in the Neonatal Intensive Care Unit in Bangladeshi Patterns
Patient X-ray Exposure and ALARA in the Neonatal Intensive Care Unit in Bangladeshi Patterns
X-ray imaging plays a crucial role in diagnosing pre-term infants in neonatal intensive care units (NICUs); however, neonates are particularly sensitive to the risks of ionizing ra...

