Javascript must be enabled to continue!
Control of Reduced Switches Count and Classical Multilevel Inverters: a Comparison
View through CrossRef
Multilevel inverter has appeared as one of the important topologies in the area of high power and medium voltage because it can efficiently realize lower harmonics with reduced switching frequency. These Multilevel inverters (MLI) improve the energy quality shaped by producing many voltage levels. However, improving the quality of the output voltage of a multilevel inverter requires many switches, which tend to weigh down the structure and make it complex to control. This work deals with a comparison in terms of the spectral content of two configurations of thirty-one-level inverters for injection into the electrical grid. The first configuration is a classical cascaded H-bridge and the second one is a reconfigured Packed U-Cell (PUC) multilevel inverter. The classical configuration requires sixteen switches while the second uses only ten ones. The control technique based on the half-height modulation was performed and the Total Harmonic Distortion (THD) is calculated for each topology. For the PUC, we got a THD equal to 2.61% while we got 2.72% for the cascaded H-bridge. These results obtained in the MATLAB/Simulink environment, show that the reconfigured structure of the PUC inverter is a good candidate for injection into the electrical network.
Title: Control of Reduced Switches Count and Classical Multilevel Inverters: a Comparison
Description:
Multilevel inverter has appeared as one of the important topologies in the area of high power and medium voltage because it can efficiently realize lower harmonics with reduced switching frequency.
These Multilevel inverters (MLI) improve the energy quality shaped by producing many voltage levels.
However, improving the quality of the output voltage of a multilevel inverter requires many switches, which tend to weigh down the structure and make it complex to control.
This work deals with a comparison in terms of the spectral content of two configurations of thirty-one-level inverters for injection into the electrical grid.
The first configuration is a classical cascaded H-bridge and the second one is a reconfigured Packed U-Cell (PUC) multilevel inverter.
The classical configuration requires sixteen switches while the second uses only ten ones.
The control technique based on the half-height modulation was performed and the Total Harmonic Distortion (THD) is calculated for each topology.
For the PUC, we got a THD equal to 2.
61% while we got 2.
72% for the cascaded H-bridge.
These results obtained in the MATLAB/Simulink environment, show that the reconfigured structure of the PUC inverter is a good candidate for injection into the electrical network.
Related Results
Multilevel Analysis of Determinants of Cattle deaths in Ethiopia
Multilevel Analysis of Determinants of Cattle deaths in Ethiopia
Abstract
Background
The Ethiopian economy is highly dependent on agriculture. Despite being more subsistence, agricultural production plays an important role in the econom...
Comparative analysis of various multilevel inverter symmetrical topologies with minimum number of components
Comparative analysis of various multilevel inverter symmetrical topologies with minimum number of components
Multilevel inverters (MLI) are frequently used in different fields like, oil and gas sectors, installations of power supply, high power and medium voltage applications and in FACTS...
A New Symmetrical Source-Based DC/AC Converter with Experimental Verification
A New Symmetrical Source-Based DC/AC Converter with Experimental Verification
This research paper introduces a new topology for multilevel inverters, emphasizing the reduction of harmonic distortion and the optimization of the component count. The complexity...
MATLAB-Simulink environment based power quality improvement in photovoltaic system using multilevel inverter
MATLAB-Simulink environment based power quality improvement in photovoltaic system using multilevel inverter
Introduction. In this world of technical advancement, conventional resources are at the stage of destruction. To avoid such problems, we are going to use an alternative energy sour...
Robust Control Strategies For Optimal Operation Of Distributed Generation In Smart Microgrids
Robust Control Strategies For Optimal Operation Of Distributed Generation In Smart Microgrids
The high penetration of PV systems and fast communications networks increase the potential for PV inverters to support the stability and performance of smart grids and microgrids. ...
THD analysis and cost comparison for an N-level H-bridge inverter incorporating passive and active filters
THD analysis and cost comparison for an N-level H-bridge inverter incorporating passive and active filters
Multilevel H-bridge inverters have grown in popularity in electronic direct current (DC) to alternating current (AC) power conversion. In the renewable energy field, H-bridge inver...
Data from The Landscape of Isoform Switches in Human Cancers
Data from The Landscape of Isoform Switches in Human Cancers
<div>Abstract<p>Alternative usage of transcript isoforms from the same gene has been hypothesized as an important feature in cancers. However, differential usage of gen...
Data from The Landscape of Isoform Switches in Human Cancers
Data from The Landscape of Isoform Switches in Human Cancers
<div>Abstract<p>Alternative usage of transcript isoforms from the same gene has been hypothesized as an important feature in cancers. However, differential usage of gen...

