Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Seismic response of structures with friction pendulum inerter system (FPIS) under near-fault earthquakes

View through CrossRef
Near-fault ground motions with high acceleration peaks and long-period velocity pulses pose a serious threat to the reliability of engineering structures. To reduce the displacement of isolation layer and improve the seismic performance of superstructure under the near-fault ground motions, a composite isolation system, which is composed of friction pendulum system (FPS) and inerter system, namely FPIS, was used in this paper. Based on D’Alembert’s principle, the nonlinear motion equations of a base-isolated structure with FPIS were established. The damping effect of two different mechanical layouts of FPIS subsystems, i.e, series-parallel inerter system-I-FPS(SPIS-I-FPS) or series-parallel inerter system-II-FPS(SPIS-II-FPS), were investigated in this study. The strong nonlinearity of FPIS was considered, and the inerter system parameters were designed based on the principle of maximum damping enhancement. The fourth-order Runge-Kutta approach was used to solve the dynamic response of a multi-degree-of-freedom system under seismic excitations. The effectiveness of FPIS was verified by comparing the isolation layer displacement and the acceleration of superstructure calculated by MATLAB with the friction pendulum system and viscous damper (FPS-VD). The nonlinear time history analysis results indicate that within a certain additional damping range, the SPIS-I-FPS subsystem performs effectively than SPIS-II-FPS in reducing the superstructure acceleration and isolation layer displacement. To increase the energy dissipation efficiency of structures, it is recommended to increase the design parameters of the inerter system and control the friction coefficient of FPS within the range of 0.05∼0.10.
Title: Seismic response of structures with friction pendulum inerter system (FPIS) under near-fault earthquakes
Description:
Near-fault ground motions with high acceleration peaks and long-period velocity pulses pose a serious threat to the reliability of engineering structures.
To reduce the displacement of isolation layer and improve the seismic performance of superstructure under the near-fault ground motions, a composite isolation system, which is composed of friction pendulum system (FPS) and inerter system, namely FPIS, was used in this paper.
Based on D’Alembert’s principle, the nonlinear motion equations of a base-isolated structure with FPIS were established.
The damping effect of two different mechanical layouts of FPIS subsystems, i.
e, series-parallel inerter system-I-FPS(SPIS-I-FPS) or series-parallel inerter system-II-FPS(SPIS-II-FPS), were investigated in this study.
The strong nonlinearity of FPIS was considered, and the inerter system parameters were designed based on the principle of maximum damping enhancement.
The fourth-order Runge-Kutta approach was used to solve the dynamic response of a multi-degree-of-freedom system under seismic excitations.
The effectiveness of FPIS was verified by comparing the isolation layer displacement and the acceleration of superstructure calculated by MATLAB with the friction pendulum system and viscous damper (FPS-VD).
The nonlinear time history analysis results indicate that within a certain additional damping range, the SPIS-I-FPS subsystem performs effectively than SPIS-II-FPS in reducing the superstructure acceleration and isolation layer displacement.
To increase the energy dissipation efficiency of structures, it is recommended to increase the design parameters of the inerter system and control the friction coefficient of FPS within the range of 0.
05∼0.
10.

Related Results

Design and Characterization of a Non-Linear Variable Inerter in Vehicle Suspension System
Design and Characterization of a Non-Linear Variable Inerter in Vehicle Suspension System
Inerter is a two-terminal component in suspension system such that the force at the two terminals is directly proportional to the relative acceleration of these two points....
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems. Concerning fault detection, interv...
Seismic hazards along the Longmen Shan fault: Insights from stress transfer between major earthquakes and regional b value
Seismic hazards along the Longmen Shan fault: Insights from stress transfer between major earthquakes and regional b value
Abstract There are two seismic gaps (Dayi seismic gap and Tianquan-Kangding seismic gap) on the Longmen Shan fault (LMSF), despite the successively occurrence of the 2008 M...
Optimal control for hover pendulum motion of unmanned helicopter
Optimal control for hover pendulum motion of unmanned helicopter
Purpose During the authors’ practical experiments about designing hover controller for unmanned helicopter, they find pendulum motion exists, thus destroying their expected control...
Broadband and Enhanced Energy Harvesting Using Inerter Pendulum Vibration Absorber
Broadband and Enhanced Energy Harvesting Using Inerter Pendulum Vibration Absorber
Abstract Inerter-based vibration energy harvesters (VEHs) have been widely studied to harvest energy from large-scale structural vibrations. Recently, there have bee...
General classification of seismic protection systems of buildings and structures
General classification of seismic protection systems of buildings and structures
The issues of ensuring the seismic resistance of buildings and structures hold a leading position despite significant achievements in this area. This is confirmed by the significan...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Late‐Quaternary Slip Rate and Seismic Activity of the Xianshuihe Fault Zone in Southwest China
Late‐Quaternary Slip Rate and Seismic Activity of the Xianshuihe Fault Zone in Southwest China
AbstractThe Xianshuihe fault zone is a seismo‐genetic fault zone of left‐lateral slip in Southwest China. Since 1725, a total of 59 Ms ≥ 5.0 earthquakes have occurred along this fa...

Back to Top