Javascript must be enabled to continue!
Periodic patterns for resolution limit characterization of correlation plenoptic imaging
View through CrossRef
AbstractThe measurement of the spatio-temporal correlations of light provides an interesting tool to overcome the traditional limitations of standard imaging, such as the strong trade-off between spatial resolution and depth of field. In particular, using correlation plenoptic imaging, one can detect both the spatial distribution and the direction of light in a scene, pushing both resolution and depth of field to the fundamental limit imposed by wave optics. This allows one to perform refocusing of different axial planes and three-dimensional reconstruction without any spatial scanning. In the present work, we investigate the resolution limit in a particular correlation plenoptic imaging scheme, by considering periodic test patterns, which provide, through analytical results, a deeper insight in the resolution properties of this second-order imaging technique, also in comparison with standard imaging.
Springer Science and Business Media LLC
Title: Periodic patterns for resolution limit characterization of correlation plenoptic imaging
Description:
AbstractThe measurement of the spatio-temporal correlations of light provides an interesting tool to overcome the traditional limitations of standard imaging, such as the strong trade-off between spatial resolution and depth of field.
In particular, using correlation plenoptic imaging, one can detect both the spatial distribution and the direction of light in a scene, pushing both resolution and depth of field to the fundamental limit imposed by wave optics.
This allows one to perform refocusing of different axial planes and three-dimensional reconstruction without any spatial scanning.
In the present work, we investigate the resolution limit in a particular correlation plenoptic imaging scheme, by considering periodic test patterns, which provide, through analytical results, a deeper insight in the resolution properties of this second-order imaging technique, also in comparison with standard imaging.
Related Results
Tomographic‐based 3D scintillation dosimetry using a three‐view plenoptic imaging system
Tomographic‐based 3D scintillation dosimetry using a three‐view plenoptic imaging system
PurposeTo demonstrate the feasibility of a three‐plenoptic camera projection, scintillation‐based dosimetry system for measuring three‐dimensional (3D) dose distributions of static...
Efficient and Accurate Disparity Estimation from MLA-Based Plenoptic Cameras
Efficient and Accurate Disparity Estimation from MLA-Based Plenoptic Cameras
Microlens-array based plenoptic cameras capture the light field in a single shot, enabling new potential applications but also introducing additional challenges. A plenoptic image ...
Resolution Limit of Correlation Plenoptic Imaging between Arbitrary Planes
Resolution Limit of Correlation Plenoptic Imaging between Arbitrary Planes
Correlation plenoptic imaging (CPI) is an optical imaging technique based on intensity correlation measurement, which enables detecting, within fundamental physical limits, both th...
Synchronization transition with coexistence of attractors in coupled discontinuous system
Synchronization transition with coexistence of attractors in coupled discontinuous system
The studies of extended dynamics systems are relevant to the understanding of spatiotemporal patterns observed in diverse fields. One of the well-established models for such comple...
The representation of visual depth perception based on the plenoptic function in the retina and its neural computation in visual cortex V1
The representation of visual depth perception based on the plenoptic function in the retina and its neural computation in visual cortex V1
AbstractBackgroundHow it is possible to “faithfully” represent a three-dimensional stereoscopic scene using Cartesian coordinates on a plane, and how three-dimensional perceptions ...
Comparison of Inter‐Observer Bias between Low Resolution and High Resolution Scans using 3T and 7T Scanners
Comparison of Inter‐Observer Bias between Low Resolution and High Resolution Scans using 3T and 7T Scanners
IntroductionMRI can be used to assess atherosclerotic disease severity and to identify plaque components noninvasively. Vessel wall thickening can be measured with MRI and is assoc...
The Effects of Periodic Suction on Separated Flow in Diffuser
The Effects of Periodic Suction on Separated Flow in Diffuser
The effects of periodic suction on the separated flow are still unclear and the relevant researches are still scarce, thus this paper presents a periodic suction method to suppress...
Quantum imaging with optical fibre structures
Quantum imaging with optical fibre structures
(English) Two-photon quantum correlations are a resource for quantum communication, sensing, and imaging. Coincidence-based quantum imaging leverages spatiotemporal quantum correla...

