ANALISIS PERFORMA HEAT EXCHANGER OIL COOLER UPPER TIPE M10-BFG PADA UNIT 1,2,3,4 PLTA SINGKARAK UNTUK TINDAKAN PEMELIHARAAN
View through CrossRef
ABSTRACT
Heat Exchanger is equipment used to carry out the process of exchanging heat between two fluids, either liquid (hot or cold) or gas, where these fluids have different temperatures. Singkarak hydropower plant also uses a plate type heat exchanger with the code M10-BFG in operation. Serves to exchange heat in the oil used in the upper oil pot, which functions as a cooler and lubricant for the upper bearing and thrust bearing. Seeing the function of the upper and thrust bearings, which are two important bearings in the unit. A good maintenance process is needed on the plate heat exchanger to maintain the condition of the oil at working temperature, which is at 45-55 0C. Through this research, the authors analyzed the performance of the M10-BFG plate heat exchanger with the parameters of the actual heat transfer coefficient and monthly temperature trends. After doing research with quantitative methods through data collection and data processing, it was found that unit 4 has the highest actual heat transfer coefficient of 875.666-900.574 W, but has the shortest usage time, for 42 days based on the existing trending temperature. This is because in unit 4 the oil flow (870-900 l/minute) is below standard, and the size of the heat exchanger plate (55 cm) has shrunk far from the initial value (63 cm). So it is necessary to carry out corrective maintenance on unit 4. Meanwhile, the lowest actual heat transfer coefficient is found in unit 1 with a value of 706.797-770.027 W and the longest plate heat exchanger usage time is in unit 3, with an estimated 121 days before reaching the 55 0C alarm.
Ikatan Dosen Menulis
Title: ANALISIS PERFORMA HEAT EXCHANGER OIL COOLER UPPER TIPE M10-BFG PADA UNIT 1,2,3,4 PLTA SINGKARAK UNTUK TINDAKAN PEMELIHARAAN
Description:
ABSTRACT
Heat Exchanger is equipment used to carry out the process of exchanging heat between two fluids, either liquid (hot or cold) or gas, where these fluids have different temperatures.
Singkarak hydropower plant also uses a plate type heat exchanger with the code M10-BFG in operation.
Serves to exchange heat in the oil used in the upper oil pot, which functions as a cooler and lubricant for the upper bearing and thrust bearing.
Seeing the function of the upper and thrust bearings, which are two important bearings in the unit.
A good maintenance process is needed on the plate heat exchanger to maintain the condition of the oil at working temperature, which is at 45-55 0C.
Through this research, the authors analyzed the performance of the M10-BFG plate heat exchanger with the parameters of the actual heat transfer coefficient and monthly temperature trends.
After doing research with quantitative methods through data collection and data processing, it was found that unit 4 has the highest actual heat transfer coefficient of 875.
666-900.
574 W, but has the shortest usage time, for 42 days based on the existing trending temperature.
This is because in unit 4 the oil flow (870-900 l/minute) is below standard, and the size of the heat exchanger plate (55 cm) has shrunk far from the initial value (63 cm).
So it is necessary to carry out corrective maintenance on unit 4.
Meanwhile, the lowest actual heat transfer coefficient is found in unit 1 with a value of 706.
797-770.
027 W and the longest plate heat exchanger usage time is in unit 3, with an estimated 121 days before reaching the 55 0C alarm.
Related Results
BIAYA PEMELIHARAAN ASSET TETAP TERHADAP LABA
BIAYA PEMELIHARAAN ASSET TETAP TERHADAP LABA
Biaya pemeliharaan asset tetap dan laba dalam kurun waktu tahun 2019 sampai tahun 2023 yang diperoleh Mr. Cling Laundry mengalami fluktuasi, yang disebabkan oleh berbagai macam f...
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
<div class="section abstract"><div class="htmlview paragraph">For vehicle thermoelectric generator, heat would be directly transferred into electricity by thermoelectri...
PENERAPAN DECISION SUPPORT SYSTEM PEMELIHARAAN BANGUNAN INFRASTRUKTUR SIPIL: STUDI LITERATUR
PENERAPAN DECISION SUPPORT SYSTEM PEMELIHARAAN BANGUNAN INFRASTRUKTUR SIPIL: STUDI LITERATUR
Sistem Pendukung Keputusan (DSS) memiliki peran penting dalam pengambilan keputusan kompleks,
terutama dalam pemeliharaan bangunan infrastruktur sipil, dengan memanfaatkan da...
Pemanfaatan Bahan PET Terhadap Daya Serap Air Pada Beton Pracetak Tipe U-Ditch
Pemanfaatan Bahan PET Terhadap Daya Serap Air Pada Beton Pracetak Tipe U-Ditch
Sampah merupakan salah satu pencemaran yang sangat umum ditemui pada saat ini. Hal ini disebabkan konsumsi plastik yang setiap tahunnya terus meningkat, salah satu jenis sampah pla...
Design and Analysis of a Plate Heat Exchanger in the View of Performance Improvement and Cost Reduction
Design and Analysis of a Plate Heat Exchanger in the View of Performance Improvement and Cost Reduction
Redesigning of a system is a modification of existing system for reducing the disadvantages over the system and improves the features for getting more output that are desired. For ...
Simulasi Distribusi Manpower Pemeliharaan Maskapai X Dengan Metode North West Corner, Least Cost, Dan Vogel's Approximation Method
Simulasi Distribusi Manpower Pemeliharaan Maskapai X Dengan Metode North West Corner, Least Cost, Dan Vogel's Approximation Method
Pemeliharaan pesawat udara sangat penting dilakukan. Dimana pada saat ini pesawat udara sebagai salah satu alat transportasi yang digunakan oleh masyarakat. Hal tersebut membutuhka...
Design and Optimization of a Helix Finned Tube Heat Exchanger for 2 K Superfluid Helium Vertical Test Stand
Design and Optimization of a Helix Finned Tube Heat Exchanger for 2 K Superfluid Helium Vertical Test Stand
Abstract
A 2 K heat exchanger is essential for 2 K superfluid helium cryogenic systems, as it increases cooling capacity and improves overall system efficiency. The ...
Analyzing the Effect of Magnetic Field on the Performance of Heat Exchanger
Analyzing the Effect of Magnetic Field on the Performance of Heat Exchanger
In contemporary engineering practices, optimizing heat transfer efficiency in heat exchangers stands as a pivotal pursuit across numerous industrial sectors. This pursuit is unders...