Experimental and Numerical Study on the Suppression of Pool Fire with Water Mist
View through CrossRef
The objective of this work is to investigate the diesel analog pool fire with water mist .For this purpose, a series of water mist fire suppression experiment are carried out by changing the nozzle operating pressure, the source of fire power, opening and closing the exhaust fan to analyze the inhibitory effect of water mist to oil pool fire in the enclosed compartment of 5.0m × 5.0m × 3.0m. The results shows that extinguishing efficiency first increases and then decreases when the nozzle operating pressure increases from 8MPa to 12MPa, reaching the highest efficiency at 10MPa; increasing the power of the source of fire, the burning speed increases and the water mist fire extinguishing efficiency decreases; fresh oxygen coming in when smoke exhaust fan is turned on and water mist fire suppression efficiency decreases. Using FDS to simulate the water mist extinguishing oil pool fire, the predict temperature field and extinguishing time are basically consistent with the experimental results. In the actual applications of water mist fire suppression systems engineering, we can use the FDS field simulation methods to predict the characteristic parameters variation of the fire fighting fire temperature and component concentration, which is significant to the fire extinguishing system optimized design.
Title: Experimental and Numerical Study on the Suppression of Pool Fire with Water Mist
Description:
The objective of this work is to investigate the diesel analog pool fire with water mist .
For this purpose, a series of water mist fire suppression experiment are carried out by changing the nozzle operating pressure, the source of fire power, opening and closing the exhaust fan to analyze the inhibitory effect of water mist to oil pool fire in the enclosed compartment of 5.
0m × 5.
0m × 3.
0m.
The results shows that extinguishing efficiency first increases and then decreases when the nozzle operating pressure increases from 8MPa to 12MPa, reaching the highest efficiency at 10MPa; increasing the power of the source of fire, the burning speed increases and the water mist fire extinguishing efficiency decreases; fresh oxygen coming in when smoke exhaust fan is turned on and water mist fire suppression efficiency decreases.
Using FDS to simulate the water mist extinguishing oil pool fire, the predict temperature field and extinguishing time are basically consistent with the experimental results.
In the actual applications of water mist fire suppression systems engineering, we can use the FDS field simulation methods to predict the characteristic parameters variation of the fire fighting fire temperature and component concentration, which is significant to the fire extinguishing system optimized design.
Related Results
Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle
Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle
A Water-mist spray system in several heavy-duty kitchen hood canopies is installed to efficiently control the high heat loads and grease emissions produced from the cooking process...
Effect of Cold Plasma Treatment on Microbial Load and Quality of Baby Carrots
Effect of Cold Plasma Treatment on Microbial Load and Quality of Baby Carrots
In the United States, about 80 percent of all food shipments and 91 percent of all temperature controlled freight shipments, including about 28.5 million tons of refrigerated fruit...
Experimental Studies on Water Mist Suppression of Liquid Fires with and without Additives
Experimental Studies on Water Mist Suppression of Liquid Fires with and without Additives
The purpose of this article is to examine the effect of additives on the extinguishment of liquid pool fires with water mist. Tests are conducted using gasoline, diesel, and ethano...
Efficacy and safety of surfactant administration by MIST and INSURE techniques in Neonates with Respiratory Distress Syndrome: A randomized controlled trial
Efficacy and safety of surfactant administration by MIST and INSURE techniques in Neonates with Respiratory Distress Syndrome: A randomized controlled trial
Objective: To measure the efficacy and safety of surfactant administered by MIST and INSURE to neonates with respiratory distress syndrome.
Methods: A randomized controlled t...
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Abstract Purpose: The invention relates to the oil industry, inorganic chemistry, in particular, to the methods of complex processing of formation water, using flare gas of oil and...
Experimental Study on Cooling a Hot Solid Surface with Water Mist
Experimental Study on Cooling a Hot Solid Surface with Water Mist
In this paper, a series of experiments are performed to investigate the hot solid surface cooling with water mist under different conditions, such as different initial surface temp...
Pool Piazza
Pool Piazza
<p><strong>Public swimming pools are undeniably public spaces that positively contribute to communities and cities by providing valuable amenities such as exercise, ent...
Effect of Glycerin on Stability and Antioxidant Activity of Ethyl Acetate Fraction of Secang Wood Face Mist
Effect of Glycerin on Stability and Antioxidant Activity of Ethyl Acetate Fraction of Secang Wood Face Mist
Background: Secang wood (Caesalpinia sappan L.) is a plant that contains brazilin, a natural antioxidant. A potential problem in the brazilin formulation process is that brazilin b...