Javascript must be enabled to continue!
A Pipeline for Automated Coordinate Assignment in Anatomically Accurate Biventricular Models
View through CrossRef
AbstractThere is an increased interest, in the field of cardiac modeling, for an improved coordinate system that can consistently describe local position within a heart geometry across various distinct geometries. A newly designed coordinate system, Cobiveco, meets these requirements. However, it assumes the use of biventricular models with a flat base, ignoring important cardiac structures. Therefore, we extended the scope of this state-of-the-art biventricular coordinate system to work with various heart geometries which include basal cardiac structures that were previously unaccounted for in Cobiveco. First, we implemented a semi-automated input surface assignment for increased accessibility and reproducibility of assigned coordinates. Then, we extended the coordinate system to handle more anatomically accurate biventricular models including the valve planes, which are of great interest when modeling diseases that manifest themselves in the basal area. Furthermore, we added the functionality of mapping vector data, such as myocardial fiber orientations, which are crucial for replicating the anisotropic electrical propagation in cardiac tissue.
Springer International Publishing
Title: A Pipeline for Automated Coordinate Assignment in Anatomically Accurate Biventricular Models
Description:
AbstractThere is an increased interest, in the field of cardiac modeling, for an improved coordinate system that can consistently describe local position within a heart geometry across various distinct geometries.
A newly designed coordinate system, Cobiveco, meets these requirements.
However, it assumes the use of biventricular models with a flat base, ignoring important cardiac structures.
Therefore, we extended the scope of this state-of-the-art biventricular coordinate system to work with various heart geometries which include basal cardiac structures that were previously unaccounted for in Cobiveco.
First, we implemented a semi-automated input surface assignment for increased accessibility and reproducibility of assigned coordinates.
Then, we extended the coordinate system to handle more anatomically accurate biventricular models including the valve planes, which are of great interest when modeling diseases that manifest themselves in the basal area.
Furthermore, we added the functionality of mapping vector data, such as myocardial fiber orientations, which are crucial for replicating the anisotropic electrical propagation in cardiac tissue.
Related Results
Installation Analysis of Matterhorn Pipeline Replacement
Installation Analysis of Matterhorn Pipeline Replacement
Abstract
The paper describes the installation analysis for the Matterhorn field pipeline replacement, located in water depths between 800-ft to 1200-ft in the Gul...
A Fluid-pipe-soil Approach to Stability Design of Submarine Pipelines
A Fluid-pipe-soil Approach to Stability Design of Submarine Pipelines
Abstract
The conventional approach to submarine pipeline stability design considers interactions between water and pipeline (fluid-pipe) and pipeline and seabed (...
Pipeline Resistance
Pipeline Resistance
Pipeline resistance is where an often abstract and wonky climate movement meets the bravery and boldness of Indigenous and other frontline defenders of land and water who inspire d...
Seismic Vulnerability of the Subsea Pipeline
Seismic Vulnerability of the Subsea Pipeline
Abstract
Unburied marine pipeline vulnerability under seismic impact, a new approach of investigation, and conclusion / recommendations for certain analyzed cases...
Potentials of GIS-based analyses of Ajaokuta -Kaduna-Kano gas pipeline in Nigeria
Potentials of GIS-based analyses of Ajaokuta -Kaduna-Kano gas pipeline in Nigeria
Abstract. Geographic and Information System (GIS) Potentials and emerging technologies in overcoming topographic challenges during construction of Ajaokuta-Kaduna-Kano (AKK) gas pi...
Impact of fully automated assessment on interstudy reproducibility of biventricular volumes and function in cardiac magnetic resonance imaging
Impact of fully automated assessment on interstudy reproducibility of biventricular volumes and function in cardiac magnetic resonance imaging
AbstractCardiovascular magnetic resonance (CMR) imaging provides reliable assessments of biventricular morphology and function. Since manual post-processing is time-consuming and p...
Demarcation of Right of Way (ROW) and Re-Installation of Damaged Markers of Transmission Pipeline in Balochistan, Pakistan through Geomatics Technologies: A Case Study of Zarghun to Quetta High Pressure Natural Gas Supply
Demarcation of Right of Way (ROW) and Re-Installation of Damaged Markers of Transmission Pipeline in Balochistan, Pakistan through Geomatics Technologies: A Case Study of Zarghun to Quetta High Pressure Natural Gas Supply
The alignment of gas pipelines in a rugged terrain has always been a serious challenge around the globe but they can be perfectly aligned with the help of Geo-Spatial technologies....
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
Human tissues comprise trillions of cells that populate a complex space of molecular phenotypes and functions and that vary in abundance by 4–9 orders of magnitude. Relying solely ...


