Javascript must be enabled to continue!
Seamless Detection of Cutoff Low and Preexisting Trough
View through CrossRef
<p><strong>Cutoff lows are cyclones existing in the upper troposphere developing from precursory preexisting troughs. We introduce a new method to seamlessly detect cutoff lows and even preexisting troughs aiming to improve lead time of meso scale disturbances like tornadoes. The method is based on a geometric character; in this method, a slope defined as the tangential line from a minimum point of each height depression is measured on an isobaric surface. This slope evaluates an intensity and horizontal extension (radius) of each depression. Adopting a mathematical assumption, we successfully achieved to make an algorithm to separate the depression and the local background flow. To remove the background flow enables us to detect both cutoff lows and preexisting troughs seamlessly in reanalysis height fields. So, our method would allow the life cycle to be illustrated continuously from the birth of the cutoff low, that is, from the precursory preexisting trough, and is expected to contribute to the improvement of the lead time for predicting severe weathers. Some further application examples, including tornado accompanying cases, and even for blocking highs, would be shown.</strong></p>
Copernicus GmbH
Title: Seamless Detection of Cutoff Low and Preexisting Trough
Description:
<p><strong>Cutoff lows are cyclones existing in the upper troposphere developing from precursory preexisting troughs.
We introduce a new method to seamlessly detect cutoff lows and even preexisting troughs aiming to improve lead time of meso scale disturbances like tornadoes.
The method is based on a geometric character; in this method, a slope defined as the tangential line from a minimum point of each height depression is measured on an isobaric surface.
This slope evaluates an intensity and horizontal extension (radius) of each depression.
Adopting a mathematical assumption, we successfully achieved to make an algorithm to separate the depression and the local background flow.
To remove the background flow enables us to detect both cutoff lows and preexisting troughs seamlessly in reanalysis height fields.
So, our method would allow the life cycle to be illustrated continuously from the birth of the cutoff low, that is, from the precursory preexisting trough, and is expected to contribute to the improvement of the lead time for predicting severe weathers.
Some further application examples, including tornado accompanying cases, and even for blocking highs, would be shown.
</strong></p>.
Related Results
En skvatmølle i Ljørring
En skvatmølle i Ljørring
A Horizontal Mill at Ljørring, Jutland.Horizontal water-mills have been in use in Jutland since the beginning of the Christian era 2). But the one here described shows so close a c...
River channel cutoff dynamics, Sacramento River, California, USA
River channel cutoff dynamics, Sacramento River, California, USA
AbstractWe measured patterns of river channel migration and cutoff between 1904 and 1997 on a 160 km meandering alluvial reach of the Sacramento River by intersecting a sequential ...
Geometrical Analysis of Parabolic Trough Solar Collector
Geometrical Analysis of Parabolic Trough Solar Collector
The geometric of the parabolic trough collector (PTC) is a field that should be paid special attention, knowing that a better geometry induces a better efficiency and lower costs. ...
Inversion analysis and safety evaluation of deformation of cutoff wall in Daning Reservoir
Inversion analysis and safety evaluation of deformation of cutoff wall in Daning Reservoir
There is a large amount of backfilled earth on both sides of the wall and the top of the lower wall of the Daning Reservoir’s cutoff wall, which is greatly disturbed by the project...
Optimisation of Feed Trough Angle and Separating Trough Angle for best grading efficiency of Zero energy Multi Fruit Grader
Optimisation of Feed Trough Angle and Separating Trough Angle for best grading efficiency of Zero energy Multi Fruit Grader
The Guava grader was converted into multiple fruit grader and tested on five levels of inclination angle of feed trough (18.06, 19.42, 20.82, 22.17 and 23.50°) and separating troug...
Vacuum Cavity Parabolic Trough Collector
Vacuum Cavity Parabolic Trough Collector
Without frequent cleaning, dust accumulation on parabolic trough collectors can lead to significant degradation of the performance of trough collectors over time. Owing to the natu...
Best approach in d-dimer algorithm to exclude pulmonary thromboembolism: a comparative study
Best approach in d-dimer algorithm to exclude pulmonary thromboembolism: a comparative study
Abstract
Funding Acknowledgements
Type of funding sources: None.
Background
...
REGIONAL PHOTOGEOLOGY OF THE IPSWICH BASIN-ESK TROUGH, QUEENSLAND
REGIONAL PHOTOGEOLOGY OF THE IPSWICH BASIN-ESK TROUGH, QUEENSLAND
The Ipswich Basin-Esk Trough Area of south-eastern Queensland was mapped photogeologically with the main emphasis on extending a uniform Jurassic sequence from the Surat Basin loca...

