Javascript must be enabled to continue!
New Data-Driven Models of Mass Flow Rate and Isentropic Efficiency of Dynamic Compressors
View through CrossRef
Dynamic compressors are widely used in many industrial sectors, such as air, land, and marine vehicle engines, aircraft environmental control systems (ECS), air-conditioning and refrigeration, gas turbines, gas compression and injection, etc. The data-driven formulas of mass flow rate and isentropic efficiency of dynamic compressors are required for the design, energy analysis, performance simulation, and control- and/or diagnosis-oriented dynamic simulation of such compressors and the related systems. This work develops data-driven models for predicting the performance of dynamic compressors, including empirical models for mass flow rate and isentropic efficiency, which have high prediction accuracy and broad application range. The performance maps of two multi-stage axial compressors of an aero engine and a centrifugal compressor of an aircraft ECS were chosen for evaluation of the existing empirical formulas and testing of the new models. There are 16 empirical models of mass flow rate and 14 empirical models of isentropic efficiency evaluated, and the results show that it is necessary to develop highly accurate empirical formulas both for mass flow rate and isentropic efficiency. With the data-driven method, two empirical models for mass flow rate and one for isentropic efficiency are developed. They are in general form, with some terms removable to make them simple while enhancing their applicability and prediction accuracy. The new models have much higher prediction accuracy than the best existing counterparts. The new mass flow rate models predict for the three compressors a mean absolute relative deviation (MAD) not greater than 1.3%, while the best existing models all have MAD > 2.0%. The new efficiency model predicts for the three compressors an MAD of 1.0%, 0.4%, and 1.9%, respectively, while the best existing model predicts for the three compressors an MAD of 1.8%, 0.8%, and 3.2%, respectively.
Title: New Data-Driven Models of Mass Flow Rate and Isentropic Efficiency of Dynamic Compressors
Description:
Dynamic compressors are widely used in many industrial sectors, such as air, land, and marine vehicle engines, aircraft environmental control systems (ECS), air-conditioning and refrigeration, gas turbines, gas compression and injection, etc.
The data-driven formulas of mass flow rate and isentropic efficiency of dynamic compressors are required for the design, energy analysis, performance simulation, and control- and/or diagnosis-oriented dynamic simulation of such compressors and the related systems.
This work develops data-driven models for predicting the performance of dynamic compressors, including empirical models for mass flow rate and isentropic efficiency, which have high prediction accuracy and broad application range.
The performance maps of two multi-stage axial compressors of an aero engine and a centrifugal compressor of an aircraft ECS were chosen for evaluation of the existing empirical formulas and testing of the new models.
There are 16 empirical models of mass flow rate and 14 empirical models of isentropic efficiency evaluated, and the results show that it is necessary to develop highly accurate empirical formulas both for mass flow rate and isentropic efficiency.
With the data-driven method, two empirical models for mass flow rate and one for isentropic efficiency are developed.
They are in general form, with some terms removable to make them simple while enhancing their applicability and prediction accuracy.
The new models have much higher prediction accuracy than the best existing counterparts.
The new mass flow rate models predict for the three compressors a mean absolute relative deviation (MAD) not greater than 1.
3%, while the best existing models all have MAD > 2.
0%.
The new efficiency model predicts for the three compressors an MAD of 1.
0%, 0.
4%, and 1.
9%, respectively, while the best existing model predicts for the three compressors an MAD of 1.
8%, 0.
8%, and 3.
2%, respectively.
Related Results
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract
IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
Pressure Analysis of DST Flow Period Or Slug Flow For Horizontal Wells In Homogeneous Reservoir
Pressure Analysis of DST Flow Period Or Slug Flow For Horizontal Wells In Homogeneous Reservoir
Abstract
By the transient pressure for horizontal well with constant flow rate and Duhamel's principle, this paper presents the method to calculate the transient ...
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Abstract
The orifice discharge coefficient (CD) is the constant required to correct theoretical flow rate to actual flow rate. It is known that single phase orifi...
Verification of conventional equations of state for tantalum under quasi-isentropic compression
Verification of conventional equations of state for tantalum under quasi-isentropic compression
Shock Hugoniot data have been widely used to calibrate analytic equations of state (EOSs) of condensed matter at high pressures. However, the suitability of particular analytic EOS...
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
AbstractIntroductionIn patients with 70% to 99% diameter carotid artery stenosis cerebral blood flow reserve may be protective of future ischemic cerebral events. Reserve cerebral ...
Numerical and Experimental Investigation of Photovoltaic/Thermal Systems: Parameter Analysis and Determination of Optimum Flow
Numerical and Experimental Investigation of Photovoltaic/Thermal Systems: Parameter Analysis and Determination of Optimum Flow
The emergence of photovoltaic/thermal (PV/T) technology has effectively solved the problem of high temperature and low electrical efficiency of photovoltaic cells, and significantl...
Characterization of Oil-Water Two-phase Flow Patterns in Vertical Upward Flow Pipes Based on Fractal and Chaotic Time Series Analysis
Characterization of Oil-Water Two-phase Flow Patterns in Vertical Upward Flow Pipes Based on Fractal and Chaotic Time Series Analysis
Abstract
Characterization of oil-water two-phase flow patterns in vertical upward oil-water two-phase flow having an inner diameter 18mm are elucidated based on f...

