Javascript must be enabled to continue!
Geo-electrical investigation of groundwater potential and subsurface structures in part of Pompo Village, Minna, North-central Nigeria
View through CrossRef
The electrical resistivity survey (VES) method was used to carry out groundwater investigation to delineate the aquiferous units in Pompo, which is a settlement in the neighbourhood of the Gidan Kwano campus of the Federal University of Technology, Minna. Pompo lies within the Pre-Cambrian Basement Complex of Northern Nigeria, and is mostly underlain by the Migmatic-Gneiss Complex, coarse-grained biotite granite and granodiorite. The survey was carried out on a grid of 500 m x 500 m. Interpretation of the data was done using IP2win software, in which a layering model was obtained with the digitized sounding curve for each of the six profiles. The results obtained show that the area is generally underlain by three geologic sections (lateritic top soil, weathered basement and fresh basement). However, in some sections, where the basement had experienced severe weathering leading to fracturing of the basement rocks, four layer models were obtained. The weathered basement that is the aquifer system of the study area is generally characterized by low resistivity that is less than 400 m with basement depth between 20.0 m and 35.0 m found in the eastern and south-eastern zones.
Integrity Mega Research Publishers
Title: Geo-electrical investigation of groundwater potential and subsurface structures in part of Pompo Village, Minna, North-central Nigeria
Description:
The electrical resistivity survey (VES) method was used to carry out groundwater investigation to delineate the aquiferous units in Pompo, which is a settlement in the neighbourhood of the Gidan Kwano campus of the Federal University of Technology, Minna.
Pompo lies within the Pre-Cambrian Basement Complex of Northern Nigeria, and is mostly underlain by the Migmatic-Gneiss Complex, coarse-grained biotite granite and granodiorite.
The survey was carried out on a grid of 500 m x 500 m.
Interpretation of the data was done using IP2win software, in which a layering model was obtained with the digitized sounding curve for each of the six profiles.
The results obtained show that the area is generally underlain by three geologic sections (lateritic top soil, weathered basement and fresh basement).
However, in some sections, where the basement had experienced severe weathering leading to fracturing of the basement rocks, four layer models were obtained.
The weathered basement that is the aquifer system of the study area is generally characterized by low resistivity that is less than 400 m with basement depth between 20.
0 m and 35.
0 m found in the eastern and south-eastern zones.
Related Results
Characterizing Groundwater Quality, Recharge and Distribution under Anthropogenic conditions
Characterizing Groundwater Quality, Recharge and Distribution under Anthropogenic conditions
Awareness concerning sustainable groundwater management is gaining traction and calls for adequate understanding of the complexities of natural and anthropogenic processes and how ...
Deformations caused by subsurface heat islands: a study on the Chicago Loop
Deformations caused by subsurface heat islands: a study on the Chicago Loop
The ground beneath urban areas is warming up due to anthropogenic activity, leading to subsurface urban heat islands [1]. A recent review of the literature suggests that subsurface...
Forecasting Net Groundwater Depletion in Well Irrigation Areas with Long Short-term Memory Networks
Forecasting Net Groundwater Depletion in Well Irrigation Areas with Long Short-term Memory Networks
<p>Due to the scarcity of available surface water, many irrigated areas in North China Plain (NCP) heavily rely on groundwater, which has resulted in groundwater over...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Characteristics of groundwater circulation and evolution in Yanhe spring basin driven by coal mining
Characteristics of groundwater circulation and evolution in Yanhe spring basin driven by coal mining
Abstract
The Yanhe spring basin located in the Jindong coal base is relatively short of water resources and the ecological environment is fragile. With the large-scale mini...
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAFTAR PUSTAKAAditama, M. H. R., & Selfiardy, S. (2022). Kehidupan Mahasiswa Kuliah Sambil Bekerja di Masa Pandemi Covid-19. Kidspedia: Jurnal Pendidikan Anak Usia Dini, 3(...
Indicator-based assessment of groundwater resources sustainability in South Korea
Indicator-based assessment of groundwater resources sustainability in South Korea
Groundwater level decline and quality deterioration is continuously observed nationwide in South Korea. Meanwhile, the demand for groundwater, which is relatively stable and clean ...
Origins of Groundwater Inferred from Isotopic Patterns of the Badain Jaran Desert, Northwestern China
Origins of Groundwater Inferred from Isotopic Patterns of the Badain Jaran Desert, Northwestern China
There are many viewpoints about the sources of groundwater in the Badain Jaran Desert (BJD), such as precipitation and snowmelt from the Qilian Mountains (the upper reaches [UR] of...

