For the modeling and evaluation of dual field-of-view (FOV) common-aperture dual-band imaging system performance, two factors must be considered at the same time. One is that the system must have a larger target acquisition range, and the other is that the detection range and recognition range of the system must be the same. In this paper, taking the dual FOV common-aperture visible/long-wave infrared (LWIR) imaging system as an example, the performance of the dual FOV common-aperture dual-band imaging system is modeled and evaluated using an imaging system performance model based on comprehensive resolution. Firstly, the target acquisition range of the dual FOV visible imaging system is analyzed, and the condition that the detection range is equal to the recognition range is obtained. Then, under the condition of common aperture, the target acquisition range and the relationship between detection range and recognition range of dual FOV LWIR imaging system are analyzed. The analysis results show that, under the condition of dual FOV and common aperture, when the detection and recognition ranges of the visible imaging system are equal, the detection and recognition ranges of the LWIR imaging system are not equal. When the detection and recognition ranges are close by reducing the comprehensive resolution, the target acquisition range of the dual FOV common-aperture dual-band imaging system will decrease.
Title: Modeling and evaluation of performance of dual field-of-view common-aperture dual-band imaging system
Description:
For the modeling and evaluation of dual field-of-view (FOV) common-aperture dual-band imaging system performance, two factors must be considered at the same time.
One is that the system must have a larger target acquisition range, and the other is that the detection range and recognition range of the system must be the same.
In this paper, taking the dual FOV common-aperture visible/long-wave infrared (LWIR) imaging system as an example, the performance of the dual FOV common-aperture dual-band imaging system is modeled and evaluated using an imaging system performance model based on comprehensive resolution.
Firstly, the target acquisition range of the dual FOV visible imaging system is analyzed, and the condition that the detection range is equal to the recognition range is obtained.
Then, under the condition of common aperture, the target acquisition range and the relationship between detection range and recognition range of dual FOV LWIR imaging system are analyzed.
The analysis results show that, under the condition of dual FOV and common aperture, when the detection and recognition ranges of the visible imaging system are equal, the detection and recognition ranges of the LWIR imaging system are not equal.
When the detection and recognition ranges are close by reducing the comprehensive resolution, the target acquisition range of the dual FOV common-aperture dual-band imaging system will decrease.
Related Results
Spin-wave band gaps created by rotating square rods in triangular lattice magnonic crystals
Spin-wave band gaps created by rotating square rods in triangular lattice magnonic crystals
Recently, magnonic crystals which are the magnetic counterparts of photonic crystals or phononic crystals are becoming a hot area of research. In this paper, band structure of two-...
Volume 10, Index
Volume 10, Index
<p><strong>Vol 10, No 1 (2015)</strong></p><p><strong> </strong></p><p><a href="http://www.world-education-center.org/index...
Experimental research on the performance of a very‐small‐aperture laser
Experimental research on the performance of a very‐small‐aperture laser
SummaryVery‐small‐aperture lasers (VSALs) with different aperture shapes are fabricated. Their far‐field and near‐field performance is analyzed experimentally. The far‐field perfor...
When Does a Dual Matrix Have a Dual Generalized Inverse?
When Does a Dual Matrix Have a Dual Generalized Inverse?
This paper deals with the existence of various types of dual generalized inverses of dual matrices. New and foundational results on the necessary and sufficient conditions for vari...
Influence of pixelation effect of image sensor on resolution of Fresnel incoherent correlation holography
Influence of pixelation effect of image sensor on resolution of Fresnel incoherent correlation holography
As a new technique of photomicrography of complex optical field, the Fresnel incoherent correlation holography (FINCH) is particularly attractive in recent years because of its inc...
Optical system design of the coded aperture imaging spectrometer
Optical system design of the coded aperture imaging spectrometer
The coded aperture imaging spectrometer system based on the double-Amici-prism is designed in this paper, which includes the telescope objective, the coded template, the double-Ami...
Full-field x-ray fluorescence imaging using a Fresnel zone plate coded aperture
Full-field x-ray fluorescence imaging using a Fresnel zone plate coded aperture
We present an approach to full-field x-ray fluorescence imaging that uses a Fresnel zone plate as a coded aperture positioned between the object and detector. For this particular c...
Review of surgical devices using small aperture optics
Review of surgical devices using small aperture optics
Small aperture optics work by blocking unfocused peripheral light rays while allowing central light rays to focus on the retina. This pinhole effect creates an extended depth of fo...