Comparison of standards for the calibration of voltage, current and resistance meters
View through CrossRef
The 14th Meeting of the APMP Technical Committee on Electricity and Magnetism, held on 5 December 2011 in Kobe, Japan, decided to hold a comparison of standards for the calibration of voltage, current and resistance meters at the lowest attainable level of uncertainty. Our comparison, designated APMP.EM-S12, covered the parameters and ranges that would typically be measured during the calibration of digital multimeters in electrical laboratories. The instrument selected for the comparison was a Wavetek model 4950 Multifunction Transfer Standard.
Circulation of the travelling standard started in February 2015 and the comparison concluded in October 2016. Between each of the comparison rounds the travelling standard was returned to the National Measurement Institute, Australia (NMIA). The dependence of the instrument on temperature and humidity was determined before the start of the comparison. The drift of the instrument during the comparison was determined from measurements at the NMIA. Participant results were corrected for temperature and drift.
Comparison reference values were calculated from all participant results that survived outlier detection. Most of the results show good agreement with the comparison reference values.
Main text
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Title: Comparison of standards for the calibration of voltage, current and resistance meters
Description:
The 14th Meeting of the APMP Technical Committee on Electricity and Magnetism, held on 5 December 2011 in Kobe, Japan, decided to hold a comparison of standards for the calibration of voltage, current and resistance meters at the lowest attainable level of uncertainty.
Our comparison, designated APMP.
EM-S12, covered the parameters and ranges that would typically be measured during the calibration of digital multimeters in electrical laboratories.
The instrument selected for the comparison was a Wavetek model 4950 Multifunction Transfer Standard.
Circulation of the travelling standard started in February 2015 and the comparison concluded in October 2016.
Between each of the comparison rounds the travelling standard was returned to the National Measurement Institute, Australia (NMIA).
The dependence of the instrument on temperature and humidity was determined before the start of the comparison.
The drift of the instrument during the comparison was determined from measurements at the NMIA.
Participant results were corrected for temperature and drift.
Comparison reference values were calculated from all participant results that survived outlier detection.
Most of the results show good agreement with the comparison reference values.
Main text
To reach the main text of this paper, click on Final Report.
Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.
bipm.
org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Related Results
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
API Offshore Structures Standards: Changing Times
API Offshore Structures Standards: Changing Times
Abstract
Two instrumental series of events in the past several years have provided the impetus for API Subcommittee 2 (SC 2) to action a new strategy for the API ...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...
International Perspectives on Standards and Benchmarking in Teacher Education
International Perspectives on Standards and Benchmarking in Teacher Education
Ensuring quality teachers and quality teacher education programmes have been fundamental global concerns over the decades. High quality teachers are critical to the future developm...
A calibration method combining hand-eye calibration and TCP calibration
A calibration method combining hand-eye calibration and TCP calibration
Abstract
Robots' traditional Tool Center Point (TCP) calibration and hand-eye calibration are implemented independently, which is likely to generate large cumulative errors...