Optimal FOPI Error Voltage Control Dead-Time Compensation for PMSM Servo System
View through CrossRef
This paper proposed a dead-time compensation method with fractional-order proportional integral (FOPI) error voltage control. The disturbance voltages caused by the power devices’ dead time and non-ideal switching characteristics are compensated for with the FOPI controller and fed to the reference voltage. In this paper, the actual error voltage is calculated based on the model and actual voltage of the permanent magnet synchronous motor. Considering the parameter error of the permanent magnet synchronous motor and the voltage error caused by the dead-time effect, a FOPI controller is used to calculate the compensation voltage. An improved particle swarm optimization (PSO) algorithm is utilized to design the parameters of the FOPI controller in order to eliminate the dead-time effect, and the optimal fitness function is designed. Compared with other optimization algorithms, the improved PSO algorithm can achieve faster convergence speed in the error voltage controller parameter design. The proposed dead-time compensation method can improve the performance of the current response and eliminate the dead-time effect. This method also eliminates all harmonic disturbances and has a good suppression effect on high-frequency harmonics. The simulation and experimental results show that the dead-time compensation method using optimal FOPI error voltage control makes the current ripple smaller and the response speed faster than that of the traditional optimal integer-order PI control, thus demonstrating the effectiveness and advantages of the proposed method.
Title: Optimal FOPI Error Voltage Control Dead-Time Compensation for PMSM Servo System
Description:
This paper proposed a dead-time compensation method with fractional-order proportional integral (FOPI) error voltage control.
The disturbance voltages caused by the power devices’ dead time and non-ideal switching characteristics are compensated for with the FOPI controller and fed to the reference voltage.
In this paper, the actual error voltage is calculated based on the model and actual voltage of the permanent magnet synchronous motor.
Considering the parameter error of the permanent magnet synchronous motor and the voltage error caused by the dead-time effect, a FOPI controller is used to calculate the compensation voltage.
An improved particle swarm optimization (PSO) algorithm is utilized to design the parameters of the FOPI controller in order to eliminate the dead-time effect, and the optimal fitness function is designed.
Compared with other optimization algorithms, the improved PSO algorithm can achieve faster convergence speed in the error voltage controller parameter design.
The proposed dead-time compensation method can improve the performance of the current response and eliminate the dead-time effect.
This method also eliminates all harmonic disturbances and has a good suppression effect on high-frequency harmonics.
The simulation and experimental results show that the dead-time compensation method using optimal FOPI error voltage control makes the current ripple smaller and the response speed faster than that of the traditional optimal integer-order PI control, thus demonstrating the effectiveness and advantages of the proposed method.
Related Results
Improvement of Linear and Nonlinear Control for PMSM Using Computational Intelligence and Reinforcement Learning
Improvement of Linear and Nonlinear Control for PMSM Using Computational Intelligence and Reinforcement Learning
Starting from the nonlinear operating equations of the permanent magnet synchronous motor (PMSM) and from the global strategy of the field-oriented control (FOC), this article comp...
Design of permanent magnet synchronous motors including thermal aspects
Design of permanent magnet synchronous motors including thermal aspects
Purpose
– The purpose of this paper is to include thermal analysis in the design process of permanent magnet synchronous motor (PMSM). The additional objective is a...
Improved Performance for PMSM Sensorless Control Based on LADRC Controller, ESO-type Observer, DO-type Observer, and RL-TD3 Agent
Improved Performance for PMSM Sensorless Control Based on LADRC Controller, ESO-type Observer, DO-type Observer, and RL-TD3 Agent
Starting from the fact that in sensorless control systems of Permanent Magnet Synchronous Motor (PMSM) the load torque can have short and significant variations, this paper present...
Position Control of Electro-hydraulic Servo System Based on Repetitive
Control Strategy
Position Control of Electro-hydraulic Servo System Based on Repetitive
Control Strategy
Background:
When performing repetitive work in an electro-hydraulic servo system,
the expected tracking signals are often periodic signals, such as trigonometric functions. For thi...
Intelligent Decoupling Control Study of PMSM Based on the Neural Network Inverse System
Intelligent Decoupling Control Study of PMSM Based on the Neural Network Inverse System
This study obtains the analytical inverse system of a permanent magnet synchronous motor (PMSM) model based on the traditional magnetic field orientation decoupling control mode by...
Design of an AC Servo Controller for a Dynamic Simulation Test System for Hydraulic Excavators Based on a System-on-chip Architecture
Design of an AC Servo Controller for a Dynamic Simulation Test System for Hydraulic Excavators Based on a System-on-chip Architecture
The AC servo system of hydraulic excavator dynamic simulation test system is studied in this paper.The AC servo controller based on C8051F410 on-chip system is designed in this pap...
Research on fuzzy control of permanent magnet synchronous motor for a mobile robot
Research on fuzzy control of permanent magnet synchronous motor for a mobile robot
Abstract
In this paper, a biped robot powered by permanent magnet synchronous motor (PMSM) is proposed, and each leg of the robot is a 6-degrees of freedom (DOF) par...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...