Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Multiresidue Pesticides Analysis of Vegetables in Vietnam by Ultrahigh-Performance Liquid Chromatography in Combination with High-Resolution Mass Spectrometry (UPLC-Orbitrap MS)

View through CrossRef
An ultrahigh-performance liquid chromatography in combination with high-resolution mass spectrometry Thermo Q-Extractive Focus Orbitrap MS has been introduced for analysis of multiclass pesticides in vegetable samples collected in Hanoi, Vietnam. Multiclass pesticides were separated on the Thermo Hypersil Gold PFP column utilizing a gradient of the mobile phase consisting of 5 mM ammonium formate, 0.1% formic acid in deionized water, and methanol. The target analytes were detected in the full-scan mode on Thermo Scientific Q-Exactive Focus Orbitrap MS for quantitation at the optimum operating conditions. These conditions included, but not limit to, the resolution of 70000 at the full width at half maximum in both positive and negative mode, mass range from 80 to 1000 m/z, and optimized parameters for the heated electrospray ionization source. The identification of the analytes in real samples was based on retention times, mass to charge ratios, mass accuracies, and MS/MS spectra at the confirmation mode with the inclusion list of target analytes. The mass accuracies of target analytes were from −4.14 ppm (dinotefuran) to 1.42 ppm (cinosulfuron) in the neat solvent and from −3.91 ppm (spinosad D) to 1.29 ppm (cinosulfuron) in the matrix-matched solution. Target analytes in the vegetable-based matrix were extracted by the QuEChERS method. Some critical parameters of the analytical method such as linearity, repeatability, limit of detection, and limit of quantitation have been evaluated and implemented. Excellent LOD and LOQ of the developed method were achieved at the range of 0.04–0.85 and 0.13–2.9 μg·kg−1, respectively. Intraday and interday repeatability of the analytical signal (peak area, n=6) of the developed method were below 3% and 10%, correspondingly. The matrix effect, extraction recovery, and overall recovery were fully investigated by spiking experiments. Experimental results demonstrated that the ionization suppression or enhancement was the main contribution on the overall recoveries of target analytes. Finally, the in-house validated method was applied to pesticides screening in vegetables samples in local villages in Hanoi, Vietnam. The concentrations of all target analytes were below limit of quantitation and lower than US-FDA or EU maximum residue levels.
Title: Multiresidue Pesticides Analysis of Vegetables in Vietnam by Ultrahigh-Performance Liquid Chromatography in Combination with High-Resolution Mass Spectrometry (UPLC-Orbitrap MS)
Description:
An ultrahigh-performance liquid chromatography in combination with high-resolution mass spectrometry Thermo Q-Extractive Focus Orbitrap MS has been introduced for analysis of multiclass pesticides in vegetable samples collected in Hanoi, Vietnam.
Multiclass pesticides were separated on the Thermo Hypersil Gold PFP column utilizing a gradient of the mobile phase consisting of 5 mM ammonium formate, 0.
1% formic acid in deionized water, and methanol.
The target analytes were detected in the full-scan mode on Thermo Scientific Q-Exactive Focus Orbitrap MS for quantitation at the optimum operating conditions.
These conditions included, but not limit to, the resolution of 70000 at the full width at half maximum in both positive and negative mode, mass range from 80 to 1000 m/z, and optimized parameters for the heated electrospray ionization source.
The identification of the analytes in real samples was based on retention times, mass to charge ratios, mass accuracies, and MS/MS spectra at the confirmation mode with the inclusion list of target analytes.
The mass accuracies of target analytes were from −4.
14 ppm (dinotefuran) to 1.
42 ppm (cinosulfuron) in the neat solvent and from −3.
91 ppm (spinosad D) to 1.
29 ppm (cinosulfuron) in the matrix-matched solution.
Target analytes in the vegetable-based matrix were extracted by the QuEChERS method.
Some critical parameters of the analytical method such as linearity, repeatability, limit of detection, and limit of quantitation have been evaluated and implemented.
Excellent LOD and LOQ of the developed method were achieved at the range of 0.
04–0.
85 and 0.
13–2.
9 μg·kg−1, respectively.
Intraday and interday repeatability of the analytical signal (peak area, n=6) of the developed method were below 3% and 10%, correspondingly.
The matrix effect, extraction recovery, and overall recovery were fully investigated by spiking experiments.
Experimental results demonstrated that the ionization suppression or enhancement was the main contribution on the overall recoveries of target analytes.
Finally, the in-house validated method was applied to pesticides screening in vegetables samples in local villages in Hanoi, Vietnam.
The concentrations of all target analytes were below limit of quantitation and lower than US-FDA or EU maximum residue levels.

Related Results

Orbitrap and GC-Orbitrap for in situ analyses: clues from laboratory experiments
Orbitrap and GC-Orbitrap for in situ analyses: clues from laboratory experiments
<p>Introduction</p> <p>The organic molecular diversity present in extraterrestrial bodies such as asteroids and comets is of great interes...
Biodiversity potential and scientific basis for conservation in the Song Hinh - Tay Hoa area, Dak Lak province, Vietnam
Biodiversity potential and scientific basis for conservation in the Song Hinh - Tay Hoa area, Dak Lak province, Vietnam
The Song Hinh - Tay Hoa area harbors exceptional ecological and biodiversity values. Two characteristic forest ecosystems are represented: lowland and mid-montane evergreen tropica...
Tentative Identification of Chemical Constituents in Liuwei Dihuang Pills Based on UPLC-Orbitrap-MS
Tentative Identification of Chemical Constituents in Liuwei Dihuang Pills Based on UPLC-Orbitrap-MS
Background: Liuwei Dihuang Pills, a classic traditional Chinese medicine formula, has been widely used in clinical practice for its multiple pharmacological effects. However, the s...
Pembrolizumab and Sarcoma: A meta-analysis
Pembrolizumab and Sarcoma: A meta-analysis
Abstract Introduction: Pembrolizumab is a monoclonal antibody that promotes antitumor immunity. This study presents a systematic review and meta-analysis of the efficacy and safety...
Pesticides and Soil Biodiversity
Pesticides and Soil Biodiversity
It is well known that some pesticides have a negative impact on bees, birds, insects and even on human health. However, the impact of pesticides on belowground life is still poorly...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract Introduction Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...

Back to Top