Javascript must be enabled to continue!
Shear Bond Strength of a Mechanically Retained Ceramic Bracket
View through CrossRef
Abstract
The failure under shear loading of mechanically retained ceramic brackets bonded to enamel was investigated.
One light-activated dual-cure and two no-mix self-cure adhesives were compared to au Adhesive Pre-coated hracket (APC).
The results indicated that the ceramic bracket bonded with the light-activated dual-cure adhesive had a significantly higher mean shear bond strength than the other adhesive systems.
All adhesive systems usually failed cohesively with adhesive remaining attached to the bracket and enamel surfaces. There was no significant difference in failure site.
There was a significant difference in the amount of adhesive remaining attached to the enamel surface. The light-activated dual-cure adhesive and Adhesive Pre-coated brackets failed in 50% and 80% of instances respectively, with less than 10% of the adhesive remaining attached to the enamel surface. Self-cure adhesives failed usually with 10-90% of the adhesive remaining attached to the enamel surface. There were no instances of enamel damage. Three cases of bracket fracture occurred, one of these being associated with the highest recorded bond strength.
Title: Shear Bond Strength of a Mechanically Retained Ceramic Bracket
Description:
Abstract
The failure under shear loading of mechanically retained ceramic brackets bonded to enamel was investigated.
One light-activated dual-cure and two no-mix self-cure adhesives were compared to au Adhesive Pre-coated hracket (APC).
The results indicated that the ceramic bracket bonded with the light-activated dual-cure adhesive had a significantly higher mean shear bond strength than the other adhesive systems.
All adhesive systems usually failed cohesively with adhesive remaining attached to the bracket and enamel surfaces.
There was no significant difference in failure site.
There was a significant difference in the amount of adhesive remaining attached to the enamel surface.
The light-activated dual-cure adhesive and Adhesive Pre-coated brackets failed in 50% and 80% of instances respectively, with less than 10% of the adhesive remaining attached to the enamel surface.
Self-cure adhesives failed usually with 10-90% of the adhesive remaining attached to the enamel surface.
There were no instances of enamel damage.
Three cases of bracket fracture occurred, one of these being associated with the highest recorded bond strength.
Related Results
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Effect of Ceramic Surface Treatment and Adhesive Systems on Bond Strength of Metallic Brackets
Effect of Ceramic Surface Treatment and Adhesive Systems on Bond Strength of Metallic Brackets
Objective. This study evaluated the effect of ceramic surface treatments on bond strength of metal brackets to machinable ceramics and veneering porcelain using different adhesive ...
Observations of the soil particle movement during direct shear tests on soil-geosynthetic interfaces
Observations of the soil particle movement during direct shear tests on soil-geosynthetic interfaces
The shear strength between soil-geosynthetic interface has been well studied by conducting large scale direct shear tests. However, the documents of the development of shear band a...
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Magnetoelectric (ME) composites have recently attracted much attention and triggered a great number of research activities, owing to their potential applications in sensors and tra...
2 mils Au wire interchip wedge bond cratering study
2 mils Au wire interchip wedge bond cratering study
Au wire thermosonic wedge bonding is applied for die to die interconnect on accelerometer device. With the fragile bond pad structure of MEMS device, bond pad cratering or bond pad...
A Comparative Evaluation of Shear Bond Strength of Moisture Tolerant Pit and Fissure Sealant and Flowable Composite: An In vitro Study
A Comparative Evaluation of Shear Bond Strength of Moisture Tolerant Pit and Fissure Sealant and Flowable Composite: An In vitro Study
Abstract
Background
The retention rate of a pit and fissure sealant is directly related to the micromechanical bond between the sealant and ename...
Efficiency of Steel Fibers in Improving the Performance of Concrete Beams without Shear Reinforcement
Efficiency of Steel Fibers in Improving the Performance of Concrete Beams without Shear Reinforcement
This research aims to experimentally study the shear strength of steel fiber concrete beams without shear reinforcement (stirrups). Parameters of the study include two compressive ...
Geophysical Characterization of Shear Zone in Direct Shear Test
Geophysical Characterization of Shear Zone in Direct Shear Test
Shear behavior of granular soils largely affects the safety and stability of underground and earth structures. This study presents the characteristics of the shear zone in a direct...


