Local Myoelectric Sensing During Human Colonic Tissue Perfusion
View through CrossRef
Objectives: Anastomotic leakage (AL) is one of the most devastating complications after colorectal surgery. The verification of the adequate perfusion of the anastomosis is essential to ensuring anastomosis integrity following colonic resections. This study aimed to evaluate the efficacy of measuring the electrical activity of the colonic muscularis externa at an anastomosis site for perfusion analysis following colorectal surgery. Methods: Strips of human isolated colon were maintained in a horizontal tissue bath to record spontaneous contractions and myoelectric activity and spike potentials (using a bipolar electrode array for the wireless transmission of myoelectric data—the xBar system) from the circular muscle. Intraoperative myoelectric signal assessment was performed by placing the electrode array on the colon prior to and following mesenteric artery ligation, just prior to colonic resection. Results: In human isolated colon, the amplitude, duration, and frequency of contractions were inhibited during hypoxia by >80% for each measurement, compared to control values and time-matched oxygenated muscle. Intraoperative (N = 5; mean age, 64.8 years; range, 54–74 years; 60% females) myoelectric signal assessment revealed a decline in spike rate following arterial ligation, with a mean reduction of 112.64 to 51.13 spikes/min (p < 0.0008). No adverse events were observed during the study, and the device did not substantially alter the surgical procedure. Conclusions: The electrical and contraction force of the human colon was reduced by ischemia, both in vitro and in vivo. These preliminary findings also suggest the potential of the xBar system to measure such changes during intraoperative and possibly postoperative periods to predict the risk of anastomotic viability as a surrogate of evolving dehiscence.
Title: Local Myoelectric Sensing During Human Colonic Tissue Perfusion
Description:
Objectives: Anastomotic leakage (AL) is one of the most devastating complications after colorectal surgery.
The verification of the adequate perfusion of the anastomosis is essential to ensuring anastomosis integrity following colonic resections.
This study aimed to evaluate the efficacy of measuring the electrical activity of the colonic muscularis externa at an anastomosis site for perfusion analysis following colorectal surgery.
Methods: Strips of human isolated colon were maintained in a horizontal tissue bath to record spontaneous contractions and myoelectric activity and spike potentials (using a bipolar electrode array for the wireless transmission of myoelectric data—the xBar system) from the circular muscle.
Intraoperative myoelectric signal assessment was performed by placing the electrode array on the colon prior to and following mesenteric artery ligation, just prior to colonic resection.
Results: In human isolated colon, the amplitude, duration, and frequency of contractions were inhibited during hypoxia by >80% for each measurement, compared to control values and time-matched oxygenated muscle.
Intraoperative (N = 5; mean age, 64.
8 years; range, 54–74 years; 60% females) myoelectric signal assessment revealed a decline in spike rate following arterial ligation, with a mean reduction of 112.
64 to 51.
13 spikes/min (p < 0.
0008).
No adverse events were observed during the study, and the device did not substantially alter the surgical procedure.
Conclusions: The electrical and contraction force of the human colon was reduced by ischemia, both in vitro and in vivo.
These preliminary findings also suggest the potential of the xBar system to measure such changes during intraoperative and possibly postoperative periods to predict the risk of anastomotic viability as a surrogate of evolving dehiscence.
Related Results
Abstracts for the 6th European Symposium on Gastrointestinal Motility 19–21 NOVEMBER 1992 HOTEL MELIA BARCELONA, BARCELONA, SPAIN
Abstracts for the 6th European Symposium on Gastrointestinal Motility 19–21 NOVEMBER 1992 HOTEL MELIA BARCELONA, BARCELONA, SPAIN
MOTOR RESPONSES OF HUMAN ILEUM TO TACHYKININS IN VITRO: EXISTENCE OF NK2 RECEPTORS AND RECEPTORS SPECIFIC FOR NEUROPEPTIDE GAMMA.INNERVATION OF THE MUSCULARIS MUCOSAE OF HUMAN COLO...
An objective approach to assess colonic pain in mice using colonometry
An objective approach to assess colonic pain in mice using colonometry
ABSTRACT
The present study presents a non-surgical approach to assess colonic mechanical sensitivity in mice using colonometry, a technique in wh...
Comparison of vibrotactile and joint-torque feedback in a myoelectric upper-limb prosthesis
Comparison of vibrotactile and joint-torque feedback in a myoelectric upper-limb prosthesis
Abstract
Background
Despite the technological advancements in myoelectric prostheses, body-powered prostheses remain a popular ...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Optimisation des montages de perfusion en anesthésie-réanimation : au travers d'expériences cliniques
Optimisation des montages de perfusion en anesthésie-réanimation : au travers d'expériences cliniques
Au cours de l’administration simultanée de plusieurs médicaments injectables, sont utilisées une ligne principale de perfusion et une ou plusieurs ligne(s) en dérivation. La ligne ...
PS01.160: PERIOPERATIVE PERFUSION ASSESSMENT WITH QUANTITATIVE FLUORESCENCE ANGIOGRAPHY
PS01.160: PERIOPERATIVE PERFUSION ASSESSMENT WITH QUANTITATIVE FLUORESCENCE ANGIOGRAPHY
Abstract
Background
Anastomotic leakage (AL) occurs relatively frequent in oncologic esophageal surgery and is associated with i...
Evaluation of Influence of Acupuncture and Electro‐Acupuncture for Blood Perfusion of Stomach by Laser Doppler Blood Perfusion Imaging
Evaluation of Influence of Acupuncture and Electro‐Acupuncture for Blood Perfusion of Stomach by Laser Doppler Blood Perfusion Imaging
The objective of this study is to observe effects of acupuncture and electro‐acupuncture (EA) on blood perfusion in the stomach, and probe into the application of laser Doppler blo...