Javascript must be enabled to continue!
Determination of diclofenac in pharmaceuticals and urine samples using a membrane sensor based on the ion associate of diclofenac with Rhodamine B
View through CrossRef
Abstract
The potentiometric response characteristics of a diclofenac selective electrode, based on ion association in different plasticizers, were compared. The sensitivity, working range, detection limit and selectivity of membrane sensors demonstrated significant dependence on the type of plasticizers. The potentiometric unit presented a linear response toward diclofenac concentrations between 1 × 10−5 − 5 × 10−2 mol L−1, with slopes of approximately 60 mV dec−1, and exhibited a response time of 3 s. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was perfomed by the membrane electrode proposed and compared with the results of potentiometric titration given by the Pharmacopoeia of Ukraine.
Walter de Gruyter GmbH
Title: Determination of diclofenac in pharmaceuticals and urine samples using a membrane sensor based on the ion associate of diclofenac with Rhodamine B
Description:
Abstract
The potentiometric response characteristics of a diclofenac selective electrode, based on ion association in different plasticizers, were compared.
The sensitivity, working range, detection limit and selectivity of membrane sensors demonstrated significant dependence on the type of plasticizers.
The potentiometric unit presented a linear response toward diclofenac concentrations between 1 × 10−5 − 5 × 10−2 mol L−1, with slopes of approximately 60 mV dec−1, and exhibited a response time of 3 s.
The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was perfomed by the membrane electrode proposed and compared with the results of potentiometric titration given by the Pharmacopoeia of Ukraine.
Related Results
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
PO-258 Women's Freestyle Wrestling Athletes Prepare for Urine Ten Evaluation Before the National Games
PO-258 Women's Freestyle Wrestling Athletes Prepare for Urine Ten Evaluation Before the National Games
Objective Urine routines inspection was used as a kind of non invasive test method, which was used widely in the biochemical monitoring of athletes.The urine routine was monitored ...
Development of a Miniature Sensor for Point-of-Care Determination of Mercury
Development of a Miniature Sensor for Point-of-Care Determination of Mercury
Mercury is toxic to human health. In developing countries, artisanal and small scale gold mining (ASGM) entails mixing elemental mercury with crushed sediments to amalgamate gold. ...
SAT656 Weight Reduction After 6 Months Of Setmelanotide Treatment In Patients With Hypothalamic Obesity
SAT656 Weight Reduction After 6 Months Of Setmelanotide Treatment In Patients With Hypothalamic Obesity
Abstract
Disclosure: C.L. Roth: Other; Self; Received research support from Rhythm Pharmaceuticals, Inc. A.H. Shoemaker: Advisory Board Member; Self; Received paymen...
The Efficacy of Pentazocine + Diclofenac Versus Paracetamol + Diclofenac for Post- Caesarean Section Analgesia
The Efficacy of Pentazocine + Diclofenac Versus Paracetamol + Diclofenac for Post- Caesarean Section Analgesia
Background:
The most common major obstetric procedure is caesarean section (CS) and one of the greatest concerns for women after CS is to have optimal pain relief.
...
Acidification is required for calcium and magnesium concentration measurements in equine urine
Acidification is required for calcium and magnesium concentration measurements in equine urine
Abstract
Background
Acidification of equine urine to promote dissociation of ion complexes is a common practice for urine ion concentration measurem...
A new topical formulation enhances relative diclofenac bioavailability in healthy male subjects
A new topical formulation enhances relative diclofenac bioavailability in healthy male subjects
WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT • Therapy with topical non‐steroidal anti‐inflammatory drugs (NSAIDs) relies on the ability of the active drug to penetrate the skin in suf...

