Determination of permanent corrections of ball reflectors

View through CrossRef
Today, there are many manufacturers of triple-prism, spherical reflectors with different mechanical characteristics. That is why there is a problem of matching the signal reflection center with the geometric one. The purpose of this work is to evaluate the methods of determining permanent corrections of electronic tacheometers, ball reflectors and to develop recommendations for their use. Method. To determine the instrument correction, a displacement interferometer is used. It contains a two-frequency He-Ne laser with a wavelength of l = 0.63 μm (red range). The study compared the results of length measurements by an interferometer and an electronic total station with a ball reflector. This allowed determining the instrument correction. The research defined the constant correction of reflectors and total stations on the phase section of the field base using the method of created linear observations. Results. Experimental studies of ball reflectors of various manufacturers and Leica electronic tacheometers were conducted. The determination of constant instrument corrections of the total station and reflector using the displacement interferometer can be performed with an accuracy of 0.1 mm. This significantly depends on the accuracy of measuring lines with the total station. The use of ball reflectors with a built-in triple prism allows significant increase of distance measurement accuracy by reducing centering errors, considering the constant instrument correction (up to 0.4 mm for Leica 1201 total stations). Scientific novelty. The methods of determining permanent corrections of ball reflectors and total stations were investigated. The proposed method determines the measurement interval length with the exception of systematic constant correction of the electronic total station and reflector. Practical relevance. The use of ball reflectors is recommended for quick and unambiguous installation at points, convenience of their use for monitoring observations, as well as for increasing the accuracy of linear measurements due to the reduction of centering errors. In order to achieve high-precision measurements of short lines, it is recommended, according to the performed studies, to carefully determine the constant correction of the total station and ball prisms. This makes it possible to increase the accuracy of line measurements at least three times compared to the declared accuracy of the total station manufacturer.
Title: Determination of permanent corrections of ball reflectors
Description:
Today, there are many manufacturers of triple-prism, spherical reflectors with different mechanical characteristics.
That is why there is a problem of matching the signal reflection center with the geometric one.
The purpose of this work is to evaluate the methods of determining permanent corrections of electronic tacheometers, ball reflectors and to develop recommendations for their use.
Method.
To determine the instrument correction, a displacement interferometer is used.
It contains a two-frequency He-Ne laser with a wavelength of l = 0.
63 μm (red range).
The study compared the results of length measurements by an interferometer and an electronic total station with a ball reflector.
This allowed determining the instrument correction.
The research defined the constant correction of reflectors and total stations on the phase section of the field base using the method of created linear observations.
Results.
Experimental studies of ball reflectors of various manufacturers and Leica electronic tacheometers were conducted.
The determination of constant instrument corrections of the total station and reflector using the displacement interferometer can be performed with an accuracy of 0.
1 mm.
This significantly depends on the accuracy of measuring lines with the total station.
The use of ball reflectors with a built-in triple prism allows significant increase of distance measurement accuracy by reducing centering errors, considering the constant instrument correction (up to 0.
4 mm for Leica 1201 total stations).
Scientific novelty.
The methods of determining permanent corrections of ball reflectors and total stations were investigated.
The proposed method determines the measurement interval length with the exception of systematic constant correction of the electronic total station and reflector.
Practical relevance.
The use of ball reflectors is recommended for quick and unambiguous installation at points, convenience of their use for monitoring observations, as well as for increasing the accuracy of linear measurements due to the reduction of centering errors.
In order to achieve high-precision measurements of short lines, it is recommended, according to the performed studies, to carefully determine the constant correction of the total station and ball prisms.
This makes it possible to increase the accuracy of line measurements at least three times compared to the declared accuracy of the total station manufacturer.

Related Results

Analytical and Low-Order Numerical Modeling of Ball-to-Ball Contact Friction in Linear Ball Bearings and Ball Screws
Analytical and Low-Order Numerical Modeling of Ball-to-Ball Contact Friction in Linear Ball Bearings and Ball Screws
Abstract Analytical and low-order numerical models are very useful for studying friction behavior of rolling element machine components like ball bearings and ball s...
Effects of Ball Groupings on Ball Passage Vibrations of a Linear Guideway Type Ball Bearing (Pitching and Yawing Ball Passage Vibrations)
Effects of Ball Groupings on Ball Passage Vibrations of a Linear Guideway Type Ball Bearing (Pitching and Yawing Ball Passage Vibrations)
The effects of ball groupings on the pitching and yawing ball passage vibrations of linear guideway type ball bearings (linear ball bearings) under low-speed operation were studied...
Ball Direction Prediction for Wheeled Soccer Robot Goalkeeper Using Trigonometry Technique
Ball Direction Prediction for Wheeled Soccer Robot Goalkeeper Using Trigonometry Technique
In this research Trigonometry Technique was implemented to predict the ball movement direction for Wheeled Soccer Robot Goalkeeper. The performance of goalkeeper robot in Wheeled S...
PERFORMANCE EVALUATION OF REFLECTORS AND COOLING SYSTEM ON PHOTOVOLTAIC SYSTEM IN KANO NORTHWEST NIGERIA
PERFORMANCE EVALUATION OF REFLECTORS AND COOLING SYSTEM ON PHOTOVOLTAIC SYSTEM IN KANO NORTHWEST NIGERIA
In the effort to improve the efficiency of a photovoltaic system, previous studies have demonstrated the potential of solar reflectors and cooling systems to enhance the performanc...
QUIET EYE DURATION AND PERFORMANCE OUTCOME IN PETANQUE
QUIET EYE DURATION AND PERFORMANCE OUTCOME IN PETANQUE
Petanque is a competitive skill sport that is popular in Malaysia. Athletes often must perform in a high-pressure situation during a game. The purpose of the research is to underst...
A Modeling and Analysis Method of Dynamic Contact Stress Inside an Automotive Ball Joint
A Modeling and Analysis Method of Dynamic Contact Stress Inside an Automotive Ball Joint
<div class="section abstract"><div class="htmlview paragraph">A ball joint is an important component of the automotive drive shaft system, as well the contact stress in...
Explosions of Ball Lightning inside Enclosed Spaces
Explosions of Ball Lightning inside Enclosed Spaces
According to observations, the energy density contained inside ball lightning can reach 1010 J/m3, and its charge can range from 10−3 to 10−1 C. Witnesses often report seeing movin...
Ball Detection and Tracking through Image Processing using Python
Ball Detection and Tracking through Image Processing using Python
In this paper, the ball detection and tracking through image processing using python is presented. The Ball Detection and Tracking through Image Processing using Python is a projec...

Back to Top