Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Performance Enhancement of Split Air Conditioner During Evaporative Cooling Application

View through CrossRef
The increase of condenser temperature and pressure in air-conditioning leads to decreased cooling capacity and the increase of power consumption. Evaporative cooling could improve the thermal performance of the system. In this study, the evaporative cooling module was installed before the condenser to reduce the inlet air temperature to the condenser unit. The impact of condenser air temperature on the air conditioning system's overall performance was determined by varying the cooling pad discharge water flowrate of 880, 1040, and 1200 mL/min. The cooling load of 2000 W was employed in this experiment. The obtained results were compared with the air conditioning without an evaporative cooling module. It shows that the coefficient of performance (COP) increases with the increase of discharge water flow rate. The highest COP obtained is 7.09 at the flow rate of 1200 mL/min. The compressor work reduces about 6.57 % as compared with the air conditioner without evaporative cooling application. Besides, the COP increases by 12. 95 % at the highest flow rate.
Title: Performance Enhancement of Split Air Conditioner During Evaporative Cooling Application
Description:
The increase of condenser temperature and pressure in air-conditioning leads to decreased cooling capacity and the increase of power consumption.
Evaporative cooling could improve the thermal performance of the system.
In this study, the evaporative cooling module was installed before the condenser to reduce the inlet air temperature to the condenser unit.
The impact of condenser air temperature on the air conditioning system's overall performance was determined by varying the cooling pad discharge water flowrate of 880, 1040, and 1200 mL/min.
The cooling load of 2000 W was employed in this experiment.
The obtained results were compared with the air conditioning without an evaporative cooling module.
It shows that the coefficient of performance (COP) increases with the increase of discharge water flow rate.
The highest COP obtained is 7.
09 at the flow rate of 1200 mL/min.
The compressor work reduces about 6.
57 % as compared with the air conditioner without evaporative cooling application.
Besides, the COP increases by 12.
95 % at the highest flow rate.

Related Results

PELATIHAN TEKNIK PENDINGIN AIR CONDITIONER (AC) DI PT WAHLRAB MUKANING BATAM
PELATIHAN TEKNIK PENDINGIN AIR CONDITIONER (AC) DI PT WAHLRAB MUKANING BATAM
ABSTRAK Permintaan AC juga terus meningkat lantaran kegiatan work from home (WFH) masih menjadi kebiasaan bagi sebagian masyarakat Indonesia di tengah meredanya pandemi. Dam...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Design and Study of Domestic Cooling System through Roof Ventilation Assisted by Evaporative Cooling
Design and Study of Domestic Cooling System through Roof Ventilation Assisted by Evaporative Cooling
This study shows the evaluation of the indirect evaporative cooling system beneath the roof that aims to reduce the cooling load in buildings. As the energy demand for space coolin...
Intrinsic Evaporative Cooling by Hygroscopic Earth Materials
Intrinsic Evaporative Cooling by Hygroscopic Earth Materials
The phase change of water from liquid to vapor is one of the most energy-intensive physical processes in nature, giving it immense potential for cooling. Diverse evaporative coolin...
Adsorption Cooling With Multi-Stage Desiccant Processes
Adsorption Cooling With Multi-Stage Desiccant Processes
For traditional adsorption cooling systems using silica-gel-like desiccant wheels, the moisture is removed from the air and stored in the desiccant wheels. The subsequent reactivat...
Cooling of Air in Outdoor Areas of Human Habitation
Cooling of Air in Outdoor Areas of Human Habitation
This paper deals with the issue of air cooling in outdoor areas of human habitation. An analysis of air parameters during the summer season was carried out to determine the thermal...
Development of Liquid Surface Conditioner
Development of Liquid Surface Conditioner
<div class="htmlview paragraph">Conventional surface conditioners for use during zinc phosphating of auto bodies use a Ti colloid. The Ti colloid is very effective as a surfa...
Neural Network Based Bin Analysis for Indirect/Direct Evaporative Cooling of Modular Data Centers
Neural Network Based Bin Analysis for Indirect/Direct Evaporative Cooling of Modular Data Centers
With an increase in the need for energy efficient data centers, a lot of research is being done to maximize the use of Air Side Economizers (ASEs), Direct Evaporative Cooling (DEC)...

Back to Top