Experimental Study on Cooling a Hot Solid Surface with Water Mist
View through CrossRef
In this paper, a series of experiments are performed to investigate the hot solid surface cooling with water mist under different conditions, such as different initial surface temperatures and mist characteristics (droplet size, droplet velocity, etc.), while these parameters are simultaneously varied. A 150 150 10mm 3chrome-plated stainless steel plate is heated from below by a 1500-W electric cooker continuously. A downward pressure nozzle is positioned on a square steel plate, 1000mm above the surface to inject water mist, the 0.5mm K-type thermocouples are jointed on the surface to obtain its temperature, and a TVS-2000ST Thermography is used to visualize the transient thermal behavior of a water mist and obtain the temperature distribution of the surface. The characteristics of the water mist are obtained by a modified PIVS (Particle Image Velocimetry and Sizing) technique previously. Based on the experiments, the effects of mist parameters and the initial surface temperature on droplet evaporative cooling are analyzed. Further discussion is carried out by considering the relationship between these parameters and the droplet Weber number, the results show that an inverse relationship between the cooling efficiency and mist droplet Weber number existed in this study.
Title: Experimental Study on Cooling a Hot Solid Surface with Water Mist
Description:
In this paper, a series of experiments are performed to investigate the hot solid surface cooling with water mist under different conditions, such as different initial surface temperatures and mist characteristics (droplet size, droplet velocity, etc.
), while these parameters are simultaneously varied.
A 150 150 10mm 3chrome-plated stainless steel plate is heated from below by a 1500-W electric cooker continuously.
A downward pressure nozzle is positioned on a square steel plate, 1000mm above the surface to inject water mist, the 0.
5mm K-type thermocouples are jointed on the surface to obtain its temperature, and a TVS-2000ST Thermography is used to visualize the transient thermal behavior of a water mist and obtain the temperature distribution of the surface.
The characteristics of the water mist are obtained by a modified PIVS (Particle Image Velocimetry and Sizing) technique previously.
Based on the experiments, the effects of mist parameters and the initial surface temperature on droplet evaporative cooling are analyzed.
Further discussion is carried out by considering the relationship between these parameters and the droplet Weber number, the results show that an inverse relationship between the cooling efficiency and mist droplet Weber number existed in this study.
Related Results
Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle
Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle
A Water-mist spray system in several heavy-duty kitchen hood canopies is installed to efficiently control the high heat loads and grease emissions produced from the cooking process...
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Abstract Purpose: The invention relates to the oil industry, inorganic chemistry, in particular, to the methods of complex processing of formation water, using flare gas of oil and...
Effect of Cold Plasma Treatment on Microbial Load and Quality of Baby Carrots
Effect of Cold Plasma Treatment on Microbial Load and Quality of Baby Carrots
In the United States, about 80 percent of all food shipments and 91 percent of all temperature controlled freight shipments, including about 28.5 million tons of refrigerated fruit...
Efficacy and safety of surfactant administration by MIST and INSURE techniques in Neonates with Respiratory Distress Syndrome: A randomized controlled trial
Efficacy and safety of surfactant administration by MIST and INSURE techniques in Neonates with Respiratory Distress Syndrome: A randomized controlled trial
Objective: To measure the efficacy and safety of surfactant administered by MIST and INSURE to neonates with respiratory distress syndrome.
Methods: A randomized controlled t...
Experimental and Numerical Study on the Suppression of Pool Fire with Water Mist
Experimental and Numerical Study on the Suppression of Pool Fire with Water Mist
The objective of this work is to investigate the diesel analog pool fire with water mist .For this purpose, a series of water mist fire suppression experiment are carried out by ch...
Research on key parameters of water mist fire protection in ship cabin
Research on key parameters of water mist fire protection in ship cabin
Abstract
Because of good cooling, heat absorption, attenuation of heat radiation and other functions, water mist is especially suitable for ship fire extinguishing a...
Combustor Effusion Cooling Multiparameter Aerothermal Numerical Analysis
Combustor Effusion Cooling Multiparameter Aerothermal Numerical Analysis
The solid temperature prediction is one of the most widespread type of modelization used in the industry. One reading this study might wonder why there would be readymade solutions...
Multi-Objective Optimization of Low-Alloy Hot-Rolled Strip Cooling Process Based on Gray Correlation Analysis
Multi-Objective Optimization of Low-Alloy Hot-Rolled Strip Cooling Process Based on Gray Correlation Analysis
The residual stress in low-alloy hot-rolled strips seriously affects the use and processing of products. Reducing residual stress is important for improving the product quality of ...