Beam optics studies for a novel gantry for hadron therapy
View through CrossRef
AbstractThe design of smaller and less costly gantries for carbon ion particle therapy represents a major challenge to the diffusion of this treatment. Here we present the work done on the linear beam optics of possible gantry layouts, differing for geometry, momentum acceptance, and magnet technology, which share the use of combined function superconducting magnets with a bending field of 4 T. We performed parallel– to–point and point–to–point optics matching at different magnification factors to provide two different beam sizes at the isocenter. Moreover, we considered the orbit distortion generated by magnet errors and we introduced beam position monitors and correctors. The study, together with considerations on the criteria for comparison, is the basis for the design of a novel and compact gantry for hadrontherapy.
Title: Beam optics studies for a novel gantry for hadron therapy
Description:
AbstractThe design of smaller and less costly gantries for carbon ion particle therapy represents a major challenge to the diffusion of this treatment.
Here we present the work done on the linear beam optics of possible gantry layouts, differing for geometry, momentum acceptance, and magnet technology, which share the use of combined function superconducting magnets with a bending field of 4 T.
We performed parallel– to–point and point–to–point optics matching at different magnification factors to provide two different beam sizes at the isocenter.
Moreover, we considered the orbit distortion generated by magnet errors and we introduced beam position monitors and correctors.
The study, together with considerations on the criteria for comparison, is the basis for the design of a novel and compact gantry for hadrontherapy.
Related Results
Rotatorlike gantry optics
Rotatorlike gantry optics
Rotating gantries are commonly used in ion-therapy facilities to assist and support optimizing the dose distribution delivered to the patient. They are installed at the end of the ...
Dynamic Tensor Modeling for Missing Data Completion in Electronic Toll Collection Gantry Systems
Dynamic Tensor Modeling for Missing Data Completion in Electronic Toll Collection Gantry Systems
The deployment of Electronic Toll Collection (ETC) gantry systems marks a transformative advancement in the journey toward an interconnected and intelligent highway traffic infrast...
SU‐E‐P‐39: Characterization of Dose Impact On Different Beam Fields Size Attenuation for Elekta IGRT Couch
SU‐E‐P‐39: Characterization of Dose Impact On Different Beam Fields Size Attenuation for Elekta IGRT Couch
Purpose:Quantification of the dosimetric impact of the Elekta IGRT treatment couch in different beam field sizes. Established the relationship of relative dose versus beam angle at...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Investigation on focus and transport characteristics of high transmission rate sheet electron beam
Investigation on focus and transport characteristics of high transmission rate sheet electron beam
The investigation on focus and transport characteristics of sheet electron beam has been a key technique for the development of high-power microwave and millimeter-wave vacuum elec...
Pembrolizumab and Sarcoma: A meta-analysis
Pembrolizumab and Sarcoma: A meta-analysis
Abstract
Introduction: Pembrolizumab is a monoclonal antibody that promotes antitumor immunity. This study presents a systematic review and meta-analysis of the efficacy and safety...
Desain dan Analisis Finite Elemen Rangka Gantry Crane Menggunakan Software Autodesk Inventor Profesional 2024
Desain dan Analisis Finite Elemen Rangka Gantry Crane Menggunakan Software Autodesk Inventor Profesional 2024
Currently, the gantry crane still uses steel material. The steel is protected using a coating paint to minimize the impact of corrosion. However, this method is inefficient given t...
Initial alignment method for free space optics laser beam
Initial alignment method for free space optics laser beam
Abstract
The authors have newly proposed and constructed an active free space optics transmission system. It is equipped with a motor driven laser emitting mechanism...