Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
View through CrossRef
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease before the arrival of transcatheter aortic valve replacement (TAVI), although limited by degeneration of the bioprosthesis. “Redo” intervention itself is burdened by high risk of complications and valve-in-valve (ViV) TAVI could be a valid strategy of redo for patients with comorbidities. The aim of this meta-analysis is to give an overview of the state of the art of ViV TAVI in high-risk patients, analyzing efficacy, safety, intra-hospital outcomes and 1-year outcomes and assess predictors of survival at short and mid-term follow up.
Methods
Two independent reviewers screened all studies investigating patients undergoing ViV TAVI. PubMed database was searched for reports published in English according to the following highly sensitive strategy: (Transcatheter[All Fields] AND “aortic”[All Fields]) AND valve-in-valve[All Fields] AND “implantation”[All Fields] NOT (review[pt] OR editorial[pt] OR letter[pt])AND “humans”[MeSH Terms]). Mortality at 30 days and at 1 year were the primary end point, while procedural and short-term outcomes and echocardiographic parameters at hospital discharge were the secondary end points.
Results
Of 286 studies identified, 26 articles were included, with a total of 1448 patients. Median age was 78.8 years, 57.7% of the patients were male. Median STS-predicted risk of mortality was 9.4% while median Logistic EuroSCORE was 31.3%. Median age of bioprosthesis was 10 years with 84.6% of stented valves. Stenosis (45%), followed by regurgitation (31%) and mixed defects (21%) were the causes of prosthesis failure. Diameter of the degenerated valve was ≤21 mm in 25.4%, 22–25 mm in 55% and >25mm in 11.7% of the patients. Transfemoral approach was preferred (76%), with a prevalence of balloon expandable valve (73.3%). Mean post procedural gradient was 16.7±0.8 mmHg. Mean follow up was 376 days. Overall and cardiovascular mortality at 30 days was 6.5% and 5.5% respectively, while at 1 year it was 14.5% and 8.9% respectively. Regarding short-term outcomes, overall bleeding (10.4%), pacemaker implantation (9.4%) and vascular complications (8.3%) were the most common peri-procedural complications, while stroke (2.3%), myocardial infarction (2.7%) and coronary obstruction (2.8%) were less frequent. At meta-regression analysis study year (p<0.001), Logistic Euroscore (p<0.01) and valve diameter ≤21 mm (p<0.05) at 30 days, and stenosis as reason for failure (p=0.05) at 1 year were identified as possible predictors of survival.
Conclusions
Percutaneous valve-in-valve aortic valve implantation offers a valid strategy to treat high risk patients with a degenerative bioprosthesis. Short and mid-term outcomes are substantially superimposable to those of TAVI, except for coronary obstruction which appears more frequent. Future studies are needed to find predictors of long- term survival and outcomes in lower risk patients.
Outcome of VIV TAVI
Funding Acknowledgement
Type of funding source: None
Oxford University Press (OUP)
Title: Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Description:
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease before the arrival of transcatheter aortic valve replacement (TAVI), although limited by degeneration of the bioprosthesis.
“Redo” intervention itself is burdened by high risk of complications and valve-in-valve (ViV) TAVI could be a valid strategy of redo for patients with comorbidities.
The aim of this meta-analysis is to give an overview of the state of the art of ViV TAVI in high-risk patients, analyzing efficacy, safety, intra-hospital outcomes and 1-year outcomes and assess predictors of survival at short and mid-term follow up.
Methods
Two independent reviewers screened all studies investigating patients undergoing ViV TAVI.
PubMed database was searched for reports published in English according to the following highly sensitive strategy: (Transcatheter[All Fields] AND “aortic”[All Fields]) AND valve-in-valve[All Fields] AND “implantation”[All Fields] NOT (review[pt] OR editorial[pt] OR letter[pt])AND “humans”[MeSH Terms]).
Mortality at 30 days and at 1 year were the primary end point, while procedural and short-term outcomes and echocardiographic parameters at hospital discharge were the secondary end points.
Results
Of 286 studies identified, 26 articles were included, with a total of 1448 patients.
Median age was 78.
8 years, 57.
7% of the patients were male.
Median STS-predicted risk of mortality was 9.
4% while median Logistic EuroSCORE was 31.
3%.
Median age of bioprosthesis was 10 years with 84.
6% of stented valves.
Stenosis (45%), followed by regurgitation (31%) and mixed defects (21%) were the causes of prosthesis failure.
Diameter of the degenerated valve was ≤21 mm in 25.
4%, 22–25 mm in 55% and >25mm in 11.
7% of the patients.
Transfemoral approach was preferred (76%), with a prevalence of balloon expandable valve (73.
3%).
Mean post procedural gradient was 16.
7±0.
8 mmHg.
Mean follow up was 376 days.
Overall and cardiovascular mortality at 30 days was 6.
5% and 5.
5% respectively, while at 1 year it was 14.
5% and 8.
9% respectively.
Regarding short-term outcomes, overall bleeding (10.
4%), pacemaker implantation (9.
4%) and vascular complications (8.
3%) were the most common peri-procedural complications, while stroke (2.
3%), myocardial infarction (2.
7%) and coronary obstruction (2.
8%) were less frequent.
At meta-regression analysis study year (p<0.
001), Logistic Euroscore (p<0.
01) and valve diameter ≤21 mm (p<0.
05) at 30 days, and stenosis as reason for failure (p=0.
05) at 1 year were identified as possible predictors of survival.
Conclusions
Percutaneous valve-in-valve aortic valve implantation offers a valid strategy to treat high risk patients with a degenerative bioprosthesis.
Short and mid-term outcomes are substantially superimposable to those of TAVI, except for coronary obstruction which appears more frequent.
Future studies are needed to find predictors of long- term survival and outcomes in lower risk patients.
Outcome of VIV TAVI
Funding Acknowledgement
Type of funding source: None.
Related Results
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Abstract
Background
Early infections after transcatheter aortic valve replacement (TAVR) represent one of the most common risk f...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Temporal trends in readmissions after transcatheter aortic valve replacement
Temporal trends in readmissions after transcatheter aortic valve replacement
Abstract
Background
Although readmissions after transcatheter aortic valve replacement (TAVR) were frequent in initial experienc...
Abstract 4136085: The Prognostic Impact of Thrombocytopenia at 6 months after Transcatheter Aortic Valve Replacement: A Retrospective Multicenter Study
Abstract 4136085: The Prognostic Impact of Thrombocytopenia at 6 months after Transcatheter Aortic Valve Replacement: A Retrospective Multicenter Study
Background:
Transient thrombocytopenia after transcatheter aortic valve replacement (TAVR) is a common phenomenon. Thrombocytopenia after TAVR during the perioperative ...
Serial Changes in Cardiac Sympathetic Nervous Function After Transcatheter Aortic Valve Replacement: A Prospective Observational Study Using 123I-meta-iodobenzylguanidine Imaging
Serial Changes in Cardiac Sympathetic Nervous Function After Transcatheter Aortic Valve Replacement: A Prospective Observational Study Using 123I-meta-iodobenzylguanidine Imaging
Abstract
Purpose:Transcatheter aortic valve replacement (TAVR) can rapidly improve cardiac sympathetic nervous function (CSNF) within 2 weeks in patients with aortic stenos...
Long-term survival and outcomes according to age for patients underwent to transcatheter aortic valve replacement
Long-term survival and outcomes according to age for patients underwent to transcatheter aortic valve replacement
Abstract
Background
Transcatheter Aortic valve Replacement (TAVR) has emerged as an alternative to surgical aortic valve replace...
Pragmatic Riser VIV Analysis
Pragmatic Riser VIV Analysis
Abstract
Drilling and production risers experiencing vortex-induced vibrations (VIV) may adversely impact operations in two ways: by increasing deflection due to ...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...