Javascript must be enabled to continue!
The Wearable Cardioverter-Defibrillator
View through CrossRef
The wearable cardioverter-defibrillator (WCD) is a rechargeable external device that can be worn under the clothing all day long and protects the wearer from potentially life-threatening ventricular tachyarrhythmias. When a dangerous arrhythmia is detected, the WCD can deliver high-energy shocks. The WCD has been shown to be effective in accurately detecting and appropriately treating ventricular tachycardia (VT) and ventricular fibrillation (VF). It is intended for temporary use as a bridge to an implantable cardioverter-defibrillator (ICD), heart transplantation, or left ventricular assist device; patients with heart failure with reduced ejection fraction may benefit from the WCD while their condition improves. It can be used temporarily after explant of an ICD until reimplantation is deemed possible. In select patients with myocardial infarction, a WCD may be useful during the immediate period after infarction. It is indicated for use when a permanently implanted ICD must be explanted because of infection; the patient can use the WCD until the infection resolves, and a new ICD can be implanted. The role of the WCD is emerging as an important therapeutic option to protect patients at elevated risk of sudden cardiac death (SCD).
Title: The Wearable Cardioverter-Defibrillator
Description:
The wearable cardioverter-defibrillator (WCD) is a rechargeable external device that can be worn under the clothing all day long and protects the wearer from potentially life-threatening ventricular tachyarrhythmias.
When a dangerous arrhythmia is detected, the WCD can deliver high-energy shocks.
The WCD has been shown to be effective in accurately detecting and appropriately treating ventricular tachycardia (VT) and ventricular fibrillation (VF).
It is intended for temporary use as a bridge to an implantable cardioverter-defibrillator (ICD), heart transplantation, or left ventricular assist device; patients with heart failure with reduced ejection fraction may benefit from the WCD while their condition improves.
It can be used temporarily after explant of an ICD until reimplantation is deemed possible.
In select patients with myocardial infarction, a WCD may be useful during the immediate period after infarction.
It is indicated for use when a permanently implanted ICD must be explanted because of infection; the patient can use the WCD until the infection resolves, and a new ICD can be implanted.
The role of the WCD is emerging as an important therapeutic option to protect patients at elevated risk of sudden cardiac death (SCD).
Related Results
The effects of age on quality of life in implantable cardioverter defibrillator recipients
The effects of age on quality of life in implantable cardioverter defibrillator recipients
Background. The implantable cardioverter defibrillator shows superiority over conventional pharmacological therapy. The implantable cardioverter defibrillator has been implanted w...
Does Patient Compliance Influence Wearable Cardioverter Defibrillator Effectiveness? A Single-Center Experience
Does Patient Compliance Influence Wearable Cardioverter Defibrillator Effectiveness? A Single-Center Experience
The study was designed to assess patient adherence to wearable cardioverter defibrillator as an indicator of device effectiveness. The patient training is not widely properly stand...
Wearable cardioverter defibrillator after cardiac surgery: Analysis of real-life data from patients at transient risk of sudden cardiac death
Wearable cardioverter defibrillator after cardiac surgery: Analysis of real-life data from patients at transient risk of sudden cardiac death
Abstract
BackgroundEspecially in the first 3 months after cardiac surgery, patients are at transient risk of sudden cardiac death (SCD). To close the gap between hospital d...
Is a Fitbit a Diary? Self-Tracking and Autobiography
Is a Fitbit a Diary? Self-Tracking and Autobiography
Data becomes something of a mirror in which people see themselves reflected. (Sorapure 270)In a 2014 essay for The New Yorker, the humourist David Sedaris recounts an obsession spu...
Peri-Infarct Quantification by Cardiac Magnetic Resonance to Predict Outcomes in Ischemic Cardiomyopathy
Peri-Infarct Quantification by Cardiac Magnetic Resonance to Predict Outcomes in Ischemic Cardiomyopathy
Background:
In ischemic cardiomyopathy, cardiac magnetic resonance assessment of the peri-infarct zone, a potential substrate for arrhythmogenesis, may serve as a novel...
Wearable Sensor Application for Integrated Early Warning and Health Surveillance
Wearable Sensor Application for Integrated Early Warning and Health Surveillance
Objective: The Wearable Sensor Application developed by Pacific Northwest National Laboratory (PNNL) provides an early warning system for stressors to individual and group health u...
Design and control of a novel all-terrains wearable vehicle
Design and control of a novel all-terrains wearable vehicle
Purpose
This paper aims to design and control of a novel compact transportation system called the “wearable vehicle”. The wearable vehicle allows for traversing all types of terrai...
Expanded application of wearable cardioverter defibrillators beyond current guidelines: proposal for a European register explained through single clinical scenarios
Expanded application of wearable cardioverter defibrillators beyond current guidelines: proposal for a European register explained through single clinical scenarios
The wearable cardioverter defibrillator (WCD) is becoming a more and more widely used instrument for the prevention of sudden cardiac death of patients either with a secondary prev...

