Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Investigation of frequency characteristics of biological tissues impedance

View through CrossRef
The problem of identifying informative signs of biological tissues viability using the impedance measurement method is formulated. At present there is no instrumental base that makes it possible in an operational setting to diagnose the ability of biological tissue to heal itself after injury and damage as a result of thermal exposure, gunshot wound or prolonged compression. It is shown in this article that development of methods and tools for instrumental diagnostics in medical diagnostic practice is an important modern challenge. The results of experimental measurements of impedance characteristics in the frequency range of 20 Hz – 2.0 MHz are presented. The frequency dependences of the modulus of voltage on biological tissues of plant origin are analyzed in its intact state, as well as after exposure of biological tissue samples in a freezer at time intervals from 15 minutes to 2 hours. A comparative analysis of the obtained frequency dependences is carried out. A significant difference between the frequency dependences of the voltage modulus on biological tissues and the frequency dependence of the voltage modulus on an isotonic solution is shown. The concept is introduced that the degree of difference between the frequency distribution of the biological tissue impedance module from the impedance module of an isotonic solution can serve as a criterion for assessing the degree of damage to biological tissue. A conclusion is made about the advisability of developing the impedance measurement method as a method for diagnosing the viability of biological tissue; it is shown that the most promising approach to the development of impedance measurement methods is the analysis of transient processes when biological tissue is disturbed by small electric current pulses.
Kharkiv National University of Radioelectronics
Title: Investigation of frequency characteristics of biological tissues impedance
Description:
The problem of identifying informative signs of biological tissues viability using the impedance measurement method is formulated.
At present there is no instrumental base that makes it possible in an operational setting to diagnose the ability of biological tissue to heal itself after injury and damage as a result of thermal exposure, gunshot wound or prolonged compression.
It is shown in this article that development of methods and tools for instrumental diagnostics in medical diagnostic practice is an important modern challenge.
The results of experimental measurements of impedance characteristics in the frequency range of 20 Hz – 2.
0 MHz are presented.
The frequency dependences of the modulus of voltage on biological tissues of plant origin are analyzed in its intact state, as well as after exposure of biological tissue samples in a freezer at time intervals from 15 minutes to 2 hours.
A comparative analysis of the obtained frequency dependences is carried out.
A significant difference between the frequency dependences of the voltage modulus on biological tissues and the frequency dependence of the voltage modulus on an isotonic solution is shown.
The concept is introduced that the degree of difference between the frequency distribution of the biological tissue impedance module from the impedance module of an isotonic solution can serve as a criterion for assessing the degree of damage to biological tissue.
A conclusion is made about the advisability of developing the impedance measurement method as a method for diagnosing the viability of biological tissue; it is shown that the most promising approach to the development of impedance measurement methods is the analysis of transient processes when biological tissue is disturbed by small electric current pulses.

Related Results

EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Impedance -based Stability Analysis on IBR Integrated Power System
Impedance -based Stability Analysis on IBR Integrated Power System
<p dir="ltr">This thesis examines the small-signal stability of inverter-based resources (IBRs) in a power system that contains grid-forming inverters (GFMs) using impedance-...
Transmission Lines Impedance Fitting Using Analytical Impedance Equation and Frequency Response Analysis
Transmission Lines Impedance Fitting Using Analytical Impedance Equation and Frequency Response Analysis
Rational function approximation is commonly used to fit the transmission line impedance over a wide frequency range. Nevertheless, it is computationally costly and challenging to i...
Solder joint degradation and detection using RF impedance analysis
Solder joint degradation and detection using RF impedance analysis
PurposeThe purpose of this paper is to clarify the method of using RF impedance changes as an early indicator of degradation of solder joint. It proposes the mode of crack propagat...
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Commercial wet Silver and Silver Chloride electrodes are used to monitor electrocardiogram (ECG) signals in numerous bioimpedance applications. These electrodes are frequently sing...
Impedance Analysis and Optimization Research of Power Distribution Network
Impedance Analysis and Optimization Research of Power Distribution Network
Abstract The impedance characteristics of Power Distribution Networks (PDN) at the circuit level have always been critical in high-speed circuit design. However, to address...
A Circuit Design for Impedance-based Structural Health Monitoring
A Circuit Design for Impedance-based Structural Health Monitoring
Systems and structures monitoring their own structural integrity have become an active field. One method uses the piezoelectric impedance-based structural health monitoring techniq...

Back to Top