Javascript must be enabled to continue!
“Redo” 2D–3D Fusion Technique during Endovascular Redo Aortic Repair
View through CrossRef
Purpose: The present study aims to describe a new 2D–3D fusion registration method in the case of endovascular redo aortic repair and compare the accuracy of the registration using the previously implanted devices vs. bones as landmarks. Materials and Methods: This single-center study prospectively analyzed all the patients that underwent elective endovascular re-interventions using the Redo Fusion technique between January 2016 and December 2021 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario A. Gemelli (FPUG)—IRCCS in Rome, Italy. The fusion overlay was performed twice, first using bone landmarks (bone fusion) and the second using radiopaque markers of a previous endovascular device (redo fusion). The pre-operative 3D model was fused with live fluoroscopy to create a roadmap. Longitudinal distances between the inferior margin of the target vessel in live fluoroscopy and the inferior margin of the target vessel in bone fusion and redo fusion were measured. Results: This single-center study prospectively analyzed 20 patients. There were 15 men and five women, with a median age of 69.7 (IQR 42) years. The median distance between the inferior margin of the target vessel ostium in digital subtraction angiography and the inferior margin of the target vessel ostium in bone fusion and redo fusion was 5.35 mm and 1.35 mm, respectively (p ≤ 0.0001). Conclusions: The redo fusion technique is accurate and allows the optimization of X-ray working views, supporting the endovascular navigation and vessel catheterization in case of endovascular redo aortic repair.
Title: “Redo” 2D–3D Fusion Technique during Endovascular Redo Aortic Repair
Description:
Purpose: The present study aims to describe a new 2D–3D fusion registration method in the case of endovascular redo aortic repair and compare the accuracy of the registration using the previously implanted devices vs.
bones as landmarks.
Materials and Methods: This single-center study prospectively analyzed all the patients that underwent elective endovascular re-interventions using the Redo Fusion technique between January 2016 and December 2021 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario A.
Gemelli (FPUG)—IRCCS in Rome, Italy.
The fusion overlay was performed twice, first using bone landmarks (bone fusion) and the second using radiopaque markers of a previous endovascular device (redo fusion).
The pre-operative 3D model was fused with live fluoroscopy to create a roadmap.
Longitudinal distances between the inferior margin of the target vessel in live fluoroscopy and the inferior margin of the target vessel in bone fusion and redo fusion were measured.
Results: This single-center study prospectively analyzed 20 patients.
There were 15 men and five women, with a median age of 69.
7 (IQR 42) years.
The median distance between the inferior margin of the target vessel ostium in digital subtraction angiography and the inferior margin of the target vessel ostium in bone fusion and redo fusion was 5.
35 mm and 1.
35 mm, respectively (p ≤ 0.
0001).
Conclusions: The redo fusion technique is accurate and allows the optimization of X-ray working views, supporting the endovascular navigation and vessel catheterization in case of endovascular redo aortic repair.
Related Results
A Matched Case-Control Study on Open and Endovascular Treatment of Popliteal Artery Aneurysms
A Matched Case-Control Study on Open and Endovascular Treatment of Popliteal Artery Aneurysms
Objective:
To compare early and late results of open and endovascular management of popliteal artery aneurysm in a retrospective single-center matched case-cont...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract
Background
Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...
The Nuclear Fusion Award
The Nuclear Fusion Award
The Nuclear Fusion Award ceremony for 2009 and 2010 award winners was held during the 23rd IAEA Fusion Energy Conference in Daejeon. This time, both 2009 and 2010 award winners w...
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Background:
This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixa...
Deciphering Popliteal Artery Aneurysm Patient Diversity: Insights From a Cluster Analysis of the POPART Registry
Deciphering Popliteal Artery Aneurysm Patient Diversity: Insights From a Cluster Analysis of the POPART Registry
Background
Popliteal artery aneurysms (PAAs) are the most common peripheral aneurysm. However, due to its rarity, the cumulative body of evidence regarding patient patt...
Hypertension and Abdominal Aortic Aneurysms: Risk Factors, Diagnosis, and Endovascular Treatment
Hypertension and Abdominal Aortic Aneurysms: Risk Factors, Diagnosis, and Endovascular Treatment
Introduction: Hypertension is a chronic condition characterized by persistently elevated blood pressure, which significantly contributes to cardiovascular morbidity and mortality. ...
Mortality After Elective and Ruptured Abdominal Aortic Aneurysm Surgical Repair: 12-Year Single-Center Experience of Estonia
Mortality After Elective and Ruptured Abdominal Aortic Aneurysm Surgical Repair: 12-Year Single-Center Experience of Estonia
Background and Aims:
Abdominal aortic aneurysm is a degenerative vascular pathology with high mortality due to its rupture, which is why timely treatment is cru...
Safety and efficacy of physician-modified thoracic endovascular aortic repair using a low-profile device for aortic arch lesions
Safety and efficacy of physician-modified thoracic endovascular aortic repair using a low-profile device for aortic arch lesions
Background
We investigated the safety and efficacy of physician-modified thoracic endovascular aortic repair using a low-profile device for aortic arch lesions....

