“Redo” 2D–3D Fusion Technique during Endovascular Redo Aortic Repair
View through CrossRef
Purpose: The present study aims to describe a new 2D–3D fusion registration method in the case of endovascular redo aortic repair and compare the accuracy of the registration using the previously implanted devices vs. bones as landmarks. Materials and Methods: This single-center study prospectively analyzed all the patients that underwent elective endovascular re-interventions using the Redo Fusion technique between January 2016 and December 2021 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario A. Gemelli (FPUG)—IRCCS in Rome, Italy. The fusion overlay was performed twice, first using bone landmarks (bone fusion) and the second using radiopaque markers of a previous endovascular device (redo fusion). The pre-operative 3D model was fused with live fluoroscopy to create a roadmap. Longitudinal distances between the inferior margin of the target vessel in live fluoroscopy and the inferior margin of the target vessel in bone fusion and redo fusion were measured. Results: This single-center study prospectively analyzed 20 patients. There were 15 men and five women, with a median age of 69.7 (IQR 42) years. The median distance between the inferior margin of the target vessel ostium in digital subtraction angiography and the inferior margin of the target vessel ostium in bone fusion and redo fusion was 5.35 mm and 1.35 mm, respectively (p ≤ 0.0001). Conclusions: The redo fusion technique is accurate and allows the optimization of X-ray working views, supporting the endovascular navigation and vessel catheterization in case of endovascular redo aortic repair.
Title: “Redo” 2D–3D Fusion Technique during Endovascular Redo Aortic Repair
Description:
Purpose: The present study aims to describe a new 2D–3D fusion registration method in the case of endovascular redo aortic repair and compare the accuracy of the registration using the previously implanted devices vs.
bones as landmarks.
Materials and Methods: This single-center study prospectively analyzed all the patients that underwent elective endovascular re-interventions using the Redo Fusion technique between January 2016 and December 2021 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario A.
Gemelli (FPUG)—IRCCS in Rome, Italy.
The fusion overlay was performed twice, first using bone landmarks (bone fusion) and the second using radiopaque markers of a previous endovascular device (redo fusion).
The pre-operative 3D model was fused with live fluoroscopy to create a roadmap.
Longitudinal distances between the inferior margin of the target vessel in live fluoroscopy and the inferior margin of the target vessel in bone fusion and redo fusion were measured.
Results: This single-center study prospectively analyzed 20 patients.
There were 15 men and five women, with a median age of 69.
7 (IQR 42) years.
The median distance between the inferior margin of the target vessel ostium in digital subtraction angiography and the inferior margin of the target vessel ostium in bone fusion and redo fusion was 5.
35 mm and 1.
35 mm, respectively (p ≤ 0.
0001).
Conclusions: The redo fusion technique is accurate and allows the optimization of X-ray working views, supporting the endovascular navigation and vessel catheterization in case of endovascular redo aortic repair.
Related Results
The Nuclear Fusion Award
The Nuclear Fusion Award
The Nuclear Fusion Award ceremony for 2009 and 2010 award winners was held during the 23rd IAEA Fusion Energy Conference in Daejeon. This time, both 2009 and 2010 award winners w...
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Background: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal functi...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Diseases of the Aorta
Diseases of the Aorta
This review covers the major presentations affecting the aorta: aortic aneurysms (abdominal aortic aneurysms and thoracic aortic aneurysms), acute aortic syndromes (including aorti...
Endovascular Surgery of Descending Thoracic Aorta Involved in T4 Lung Tumor
Endovascular Surgery of Descending Thoracic Aorta Involved in T4 Lung Tumor
Purpose: Surgical treatment of primary lung T4 tumors is controversial especially when the cancer invades the mediastinal structures or the descending thoracic aorta. Conventional ...
Results of endovascular aortic arch repair using the Relay Branch system
Results of endovascular aortic arch repair using the Relay Branch system
Abstract
OBJECTIVES
Our goal was to evaluate results of endovascular aortic ...
P1716 Aorto-left atrial fistula with left atrium dissection
P1716 Aorto-left atrial fistula with left atrium dissection
Abstract
We report a 71 year-old female with a history of rheumatic valvulopathy, who underwent St. Jude 23 and St. Jude 21 in ...
Management strategies for acute type A aortic dissection complicated by limb malperfusion
Management strategies for acute type A aortic dissection complicated by limb malperfusion
Abstract
Objective: Acute type A aortic dissection complicated by limb malperfusion confers a risk of mortality to the patients. And,debates still exist about how to manage...