Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

CFD Analysis of Indoor Ventilation for Airborne Virus Infection

View through CrossRef
CFD Analysis of Indoor Ventilation for Airborne Virus Infection Indoor airflow patterns and air residence times significantly influence the spread of airborne infectious viruses, such as COVID-19. These factors can be quantified using computational fluid dynamics (CFD). In this study, CFD was utilized to assess the indoor airflow patterns and calculate air residence times in a typical restroom with high personnel flow and low ventilation efficiency. The results identified regions with high air residence times, indicating potential risk areas for airborne virus retention. Furthermore, the effects of different ventilation strategies on these high-risk areas were analyzed. Despite meeting air change standards, certain regions were found to potentially pose a higher risk due to prolonged air residence times. Based on these findings, recommendations for improving ventilation systems to reduce the risk of airborne virus infection were proposed. This study highlights the necessity of a more nuanced approach to indoor air assessment than simply calculating air changes per hour. It was concluded that (1) different ventilation strategies can greatly affect the air residence time in the room and (2) the variance of air residence time in the air circulation area are large in some locations, even with simple ventilation adjustments.
Title: CFD Analysis of Indoor Ventilation for Airborne Virus Infection
Description:
CFD Analysis of Indoor Ventilation for Airborne Virus Infection Indoor airflow patterns and air residence times significantly influence the spread of airborne infectious viruses, such as COVID-19.
These factors can be quantified using computational fluid dynamics (CFD).
In this study, CFD was utilized to assess the indoor airflow patterns and calculate air residence times in a typical restroom with high personnel flow and low ventilation efficiency.
The results identified regions with high air residence times, indicating potential risk areas for airborne virus retention.
Furthermore, the effects of different ventilation strategies on these high-risk areas were analyzed.
Despite meeting air change standards, certain regions were found to potentially pose a higher risk due to prolonged air residence times.
Based on these findings, recommendations for improving ventilation systems to reduce the risk of airborne virus infection were proposed.
This study highlights the necessity of a more nuanced approach to indoor air assessment than simply calculating air changes per hour.
It was concluded that (1) different ventilation strategies can greatly affect the air residence time in the room and (2) the variance of air residence time in the air circulation area are large in some locations, even with simple ventilation adjustments.

Related Results

Scoping indoor airborne fungi in an excellent indoor air quality office building in Hong Kong
Scoping indoor airborne fungi in an excellent indoor air quality office building in Hong Kong
This study aims to investigate the differences in indoor airborne fungal exposure between a selective subset of air-conditioned offices within a building classified with excellent ...
The Impact of IL28B Gene Polymorphisms on Drug Responses
The Impact of IL28B Gene Polymorphisms on Drug Responses
To achieve high therapeutic efficacy in the patient, information on pharmacokinetics, pharmacodynamics, and pharmacogenetics is required. With the development of science and techno...
Particle Based Model for Airborne Disease Transmission
Particle Based Model for Airborne Disease Transmission
Executive SummaryPrior literature documents cases of airborne infectious disease transmission at distances ranging from ≥ 2 m to inter-continental in scale. Physics- and biology- b...
Ventilation in university classrooms during the COVID-19 pandemic
Ventilation in university classrooms during the COVID-19 pandemic
The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) virus has caused a pandemic, forcing schools and universities to stop in-person classes. For universities to allow ...
Ventilation Control of Indoor Transmission of Airborne Diseases in an Urban Community
Ventilation Control of Indoor Transmission of Airborne Diseases in an Urban Community
Following the recent severe acute respiratory syndrome epidemics and worldwide concern about the next pandemic, whether influenza or multiple drug resistant tuberculosis, has under...
Recurrence Possibility of COVID-19 in India
Recurrence Possibility of COVID-19 in India
Although nationwide lockdown was imposed in India amid COVID-19 outbreak since March 24, 2020, the COVID-19 infection is increasing day-by-day. India became world’s second most aff...
Unravelling indoor temperature response to summer heat through long-term crowdsourced observations in Dutch residences
Unravelling indoor temperature response to summer heat through long-term crowdsourced observations in Dutch residences
City dwellers are increasingly exposed to summer heat due to climate change and urbanization. Summer heat, which causes heat stress, is intensified especially at night in urban are...
Navigating dust storms and urban living: an analysis of particulate matter infiltration in Dubai’s residences
Navigating dust storms and urban living: an analysis of particulate matter infiltration in Dubai’s residences
In response to the growing concern of air pollution in Dubai, this study was undertaken to measure and analyze indoor and outdoor particulate matter (PM) concentrations in resident...

Back to Top