Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Test method for evaluating the NIOSH Noise Mapper application in a hemi-anechoic chamber

View through CrossRef
The Noise Mapper Application currently under development by the National Institute for Occupational Safety and Health (NIOSH) can be used to identify areas in the workplace where workers may be exposed to hazardous noise. The application is intended to empower workers to measure sound levels in their workplace, make informed decisions about noise exposure, and prevent occupational hearing loss. To evaluate the maps generated by the app, a single sound source or multiple sources were used to generate steady state sound fields within the NIOSH Hemi-anechoic Chamber (HAC). A sound level meter (Larson Davis, Model LxT1) was used to measure A-weighed equivalent continuous sound levels on a grid with a spacing of 1.5 m (5 ft). The NIOSH Noise Mapper Application was then used to generate sound level contour plots with a grid spacing of 3.0 m (10 ft). The accuracy of the map was evaluated by comparing the predicted sound levels with the measured sound levels. The results show the app can estimate the sound levels to within 1.5 dB(A) of the measured values when half of the measured points were used to generate the contour plot. The test method used to evaluate the NIOSH Noise Mapper Application and the results of the comparison will be discussed in this paper.
Title: Test method for evaluating the NIOSH Noise Mapper application in a hemi-anechoic chamber
Description:
The Noise Mapper Application currently under development by the National Institute for Occupational Safety and Health (NIOSH) can be used to identify areas in the workplace where workers may be exposed to hazardous noise.
The application is intended to empower workers to measure sound levels in their workplace, make informed decisions about noise exposure, and prevent occupational hearing loss.
To evaluate the maps generated by the app, a single sound source or multiple sources were used to generate steady state sound fields within the NIOSH Hemi-anechoic Chamber (HAC).
A sound level meter (Larson Davis, Model LxT1) was used to measure A-weighed equivalent continuous sound levels on a grid with a spacing of 1.
5 m (5 ft).
The NIOSH Noise Mapper Application was then used to generate sound level contour plots with a grid spacing of 3.
0 m (10 ft).
The accuracy of the map was evaluated by comparing the predicted sound levels with the measured sound levels.
The results show the app can estimate the sound levels to within 1.
5 dB(A) of the measured values when half of the measured points were used to generate the contour plot.
The test method used to evaluate the NIOSH Noise Mapper Application and the results of the comparison will be discussed in this paper.

Related Results

Test method for evaluating the NIOSH Noise Mapper application in a hemi-anechoic chamber
Test method for evaluating the NIOSH Noise Mapper application in a hemi-anechoic chamber
The Noise Mapper Application developed by the National Institute for Occupational Safety and Health (NIOSH) can be used to identify areas in the workplace where workers may be expo...
Mechanism of suppressing noise intensity of squeezed state enhancement
Mechanism of suppressing noise intensity of squeezed state enhancement
This research focuses on advanced noise suppression technologies for high-precision measurement systems, particularly addressing the limitations of classical noise reducing approac...
A Comprehensive Review of Noise Measurement, Standards, Assessment, Geospatial Mapping and Public Health
A Comprehensive Review of Noise Measurement, Standards, Assessment, Geospatial Mapping and Public Health
Noise pollution is an emerging issue in cities around the world. Noise is a pernicious pollutant in urban landscapes mainly due to the increasing number of city inhabitants, road a...
FREQUENCY OF POSTOPERATIVE COMPLICATION IN PATIENT UNDERGOING HEMI-THYROIDECTOMY WITH AND WITHOUT DRAIN
FREQUENCY OF POSTOPERATIVE COMPLICATION IN PATIENT UNDERGOING HEMI-THYROIDECTOMY WITH AND WITHOUT DRAIN
Introduction: After thyroid surgery, the need for drain placement has become a contentious topic. Drains are frequently utilized to prevent problems and help in the early detection...
Advanced numerical methodology for tyre noise prediction
Advanced numerical methodology for tyre noise prediction
"It is seen that for lower car speeds the noise generated by internal combustion engine dominates that of tyres and is vice versa at higher speeds. This is beneficiary since a road...
Research Progress of Noise in High-Speed Cutting Machining
Research Progress of Noise in High-Speed Cutting Machining
High-speed cutting technology has become a development trend in the material processing industry. However, high-intensity noise generated during high-speed cutting exerts a potenti...
Unsound Judgments
Unsound Judgments
This aural history surveys two parallel developments in the postwar United States: the commercial popularization of the white noise or “white sound” machine in the 1960s and ’70s; ...

Back to Top