Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fitting tips and tricks of challenging cases of keratoconus

View through CrossRef
AbstractPurpose to discuss the fitting tips and tricks of challenging cases of keratoconus with a special design of RGP lens namely Rose K2 lensMethods The study was carried on 52 keratoconic eyes fitted with Rose K2 lens. They were topographically classified into low cones, small steep cones, early cones, advanced cones and toric cones. The appropriate lens parameters were selected accordingly. Successful fitting was evaluated by lens position, movement, fluorescein pattern, visual acuity, residual astigmatism, patient comfort, maximum wearing time per day and corneal integrity.Results The keratoconic eyes were successfully fitted as follow: lenses with bigger diameter and considerably flatter base curve than normal were used to fit the low cones, lenses with flatter base curve, minimum diameter and maximum edge lift were used in small steep cones. Keeping the lens as small as possible and considerably steeper base curve than normal were used in advanced cones. Early cones were fitted with larger diameter lenses with decreased edge lift. Toric or astigmatic corneas were fitted acceptably either by reducing the overall diameter of the lens or using toric RGP lens. With the previous lens parameters, most of patients (96%) tolerated their lenses with maximum wearing time per day 11± 2.5 hours. No corneal staining or abrasion was encountered in studied eyes. Lenses were centrally positioned with adequate movement and acceptable fluorescein pattern. Best corrected visual acuity was significantly increased compared to the baseline visual acuity with significantly decreased astigmatism.Conclusion Patients with keratoconic corneas are sometimes challenging to fit and time consuming, but if well fitted with appropriate lens parameters, they appreciate the benefits provided by their contact lenses i
Title: Fitting tips and tricks of challenging cases of keratoconus
Description:
AbstractPurpose to discuss the fitting tips and tricks of challenging cases of keratoconus with a special design of RGP lens namely Rose K2 lensMethods The study was carried on 52 keratoconic eyes fitted with Rose K2 lens.
They were topographically classified into low cones, small steep cones, early cones, advanced cones and toric cones.
The appropriate lens parameters were selected accordingly.
Successful fitting was evaluated by lens position, movement, fluorescein pattern, visual acuity, residual astigmatism, patient comfort, maximum wearing time per day and corneal integrity.
Results The keratoconic eyes were successfully fitted as follow: lenses with bigger diameter and considerably flatter base curve than normal were used to fit the low cones, lenses with flatter base curve, minimum diameter and maximum edge lift were used in small steep cones.
Keeping the lens as small as possible and considerably steeper base curve than normal were used in advanced cones.
Early cones were fitted with larger diameter lenses with decreased edge lift.
Toric or astigmatic corneas were fitted acceptably either by reducing the overall diameter of the lens or using toric RGP lens.
With the previous lens parameters, most of patients (96%) tolerated their lenses with maximum wearing time per day 11± 2.
5 hours.
No corneal staining or abrasion was encountered in studied eyes.
Lenses were centrally positioned with adequate movement and acceptable fluorescein pattern.
Best corrected visual acuity was significantly increased compared to the baseline visual acuity with significantly decreased astigmatism.
Conclusion Patients with keratoconic corneas are sometimes challenging to fit and time consuming, but if well fitted with appropriate lens parameters, they appreciate the benefits provided by their contact lenses i.

Related Results

Asthma and Keratoconus: An analysis of the risk factors association with the severity of keratoconus
Asthma and Keratoconus: An analysis of the risk factors association with the severity of keratoconus
Abstract Background: A cross-sectional study was undertaken in Australia to explore a wide range of risk factors associated with keratoconus. A questionnaire addressing age...
A predictive model for early diagnosis of keratoconus
A predictive model for early diagnosis of keratoconus
Abstract Background: The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore to avoid possib...
A predictive model for early diagnosis of keratoconus
A predictive model for early diagnosis of keratoconus
Abstract Background: The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore, to avoid possi...
Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Corneal Deformation Response in Patients With keratoconus and in Healthy Subjects
Abstract Background To compare the corneal deformation response between patients with keratoconus and healthy subjects and to identify potential characteristics associated...
Comparison of Anterior Chamber Parameters between Normal and Keratoconus Eyes using Scheimpflug Photography
Comparison of Anterior Chamber Parameters between Normal and Keratoconus Eyes using Scheimpflug Photography
ABSTRACT Aim To evaluate anterior chamber indices including anterior chamber depth (ACD) and anterior chamber volume (ACV) with the progression of keratoconus using a rotating Sch...
Predictive model for early diagnosis of keratoconus
Predictive model for early diagnosis of keratoconus
Abstract Background To describe the topographic, pachymetric and aberrometry characteristics in patients with keratoconus, subclinical keratoconus/forme fruste and normal c...

Back to Top