Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Impact of transcatheter mitral valve repair on ventricular arrhythmias

View through CrossRef
Abstract Aims Patients with heart failure and severe mitral regurgitation (MR) have a poor prognosis and carry an increased risk for ventricular arrhythmias. The present study evaluates the impact of transcatheter mitral valve repair using the MitraClip on the potential reduction of ventricular arrhythmias. Methods and results Patients undergoing MitraClip implantation were prospectively enrolled into the present study and received 24 h Holter ECG assessment prior to and 6 months after the procedure. In addition, left ventricular dimensions and function were assessed at baseline and follow-up. A total of 50 patients with mainly functional MR (82%) were included. Non-sustained or sustained ventricular tachycardia (nsVT and/or sVT) occurred in 32% of patients and was reduced to 14% at follow-up (P = 0.01). Also, premature ventricular complex (PVC) burden ≥5% decreased from 16% to 4% (P = 0.04). Patients with persistent (n = 6) or new (n = 1) nsVT and/or sVT at follow-up showed a significant decrease in left ventricular ejection fraction from 38% (interquartile range 26–45%) to 33% (interquartile range 22–44%; P = 0.03). Conclusions In this prospective study, transcatheter mitral valve repair using MitraClip was associated with a reduced prevalence of ventricular arrhythmias. The subset of patients with persistent or new ventricular arrhythmias after MitraClip implantation showed progression of left ventricular dysfunction.
Title: Impact of transcatheter mitral valve repair on ventricular arrhythmias
Description:
Abstract Aims Patients with heart failure and severe mitral regurgitation (MR) have a poor prognosis and carry an increased risk for ventricular arrhythmias.
The present study evaluates the impact of transcatheter mitral valve repair using the MitraClip on the potential reduction of ventricular arrhythmias.
Methods and results Patients undergoing MitraClip implantation were prospectively enrolled into the present study and received 24 h Holter ECG assessment prior to and 6 months after the procedure.
In addition, left ventricular dimensions and function were assessed at baseline and follow-up.
A total of 50 patients with mainly functional MR (82%) were included.
Non-sustained or sustained ventricular tachycardia (nsVT and/or sVT) occurred in 32% of patients and was reduced to 14% at follow-up (P = 0.
01).
Also, premature ventricular complex (PVC) burden ≥5% decreased from 16% to 4% (P = 0.
04).
Patients with persistent (n = 6) or new (n = 1) nsVT and/or sVT at follow-up showed a significant decrease in left ventricular ejection fraction from 38% (interquartile range 26–45%) to 33% (interquartile range 22–44%; P = 0.
03).
Conclusions In this prospective study, transcatheter mitral valve repair using MitraClip was associated with a reduced prevalence of ventricular arrhythmias.
The subset of patients with persistent or new ventricular arrhythmias after MitraClip implantation showed progression of left ventricular dysfunction.

Related Results

P1720 Hammock mitral valve, a challenging echocardiographic diagnosis
P1720 Hammock mitral valve, a challenging echocardiographic diagnosis
Abstract We report a 43 year-old female with a past TTE echocardiography of rheumatic valve disease performed in her district h...
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Background: Mitral valve regurgitation due to degenerative valve disease is a common disease affecting about 2% of the population, mainly in developed countries  [2],[6]. Medical t...
Mitral valve surgery after a failed MitraClip procedure
Mitral valve surgery after a failed MitraClip procedure
Abstract OBJECTIVES Among patients undergoing transcatheter mitral valve repair with the MitraClip device, a relevant proportion...
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Objective: To evaluate accuracy of mitral leaflet separation index for the determination of mitral stenosis severity in patients with rheumatic mitral stenosis. Method: The prospec...
Interrelationship Between Kidney Function and Percutaneous Mitral Valve Interventions: A Comprehensive Review
Interrelationship Between Kidney Function and Percutaneous Mitral Valve Interventions: A Comprehensive Review
Percutaneous mitral valve repair is emerging as a reasonable alternative especially in those with an unfavorable surgical risk profile in the repair of mitral regurgitation. At thi...
89 Simultaneous ocurrence of hammock mitral valve and no-compaction cardiomyopathy
89 Simultaneous ocurrence of hammock mitral valve and no-compaction cardiomyopathy
Abstract We report a 62-year-old man with a past medical history of dyslipidemia, paranoid schizophrenia and permanent atrial f...
P837 Isolated cleft posterior mitral valve leaflet
P837 Isolated cleft posterior mitral valve leaflet
Abstract A 78-year-old man with a history of hypertension and diabetes mellitus was referred to the ER of our hospital due to an episode of shortness of breath of ne...
Predictors of maternal and fetal outcomes of pregnant women with mitral stenosis
Predictors of maternal and fetal outcomes of pregnant women with mitral stenosis
AbstractBackgroundValvular heart disease, in particular mitral stenosis, is associated with unfavorable pregnancy outcomes. Data on maternal and fetal outcomes of pregnant women wi...

Back to Top