Javascript must be enabled to continue!
MODIFIED APPROACH OF FORCE APPLICATION IN IZC MINI-IMPLANT FOR ARCH DISTALIZATION BY ELASTOMERIC CHAIN
View through CrossRef
Distalization of whole arch required an appropriate force of application along with sound knowledge of biomechanics. After development of mini-implants it became quite easy because it doesn't need patient compliance which was a problem in olden days with conventional extraoral appliances. Introduction of extra-radicular mini-implant (IZC mini-implant) in orthodontics makes complete arch distalization single step procedure in comparison to intra-radicular mini-implants (conventional TADs) which we have to reposition due to root approximation. This article represents a modified approach of Elastomeric chain application in IZC mini-implant for whole arch distalization.
Title: MODIFIED APPROACH OF FORCE APPLICATION IN IZC MINI-IMPLANT FOR ARCH DISTALIZATION BY ELASTOMERIC CHAIN
Description:
Distalization of whole arch required an appropriate force of application along with sound knowledge of biomechanics.
After development of mini-implants it became quite easy because it doesn't need patient compliance which was a problem in olden days with conventional extraoral appliances.
Introduction of extra-radicular mini-implant (IZC mini-implant) in orthodontics makes complete arch distalization single step procedure in comparison to intra-radicular mini-implants (conventional TADs) which we have to reposition due to root approximation.
This article represents a modified approach of Elastomeric chain application in IZC mini-implant for whole arch distalization.
.
Related Results
Impact of molar teeth distalization by clear aligners on temporomandibular joint: a three-dimensional study
Impact of molar teeth distalization by clear aligners on temporomandibular joint: a three-dimensional study
Abstract
Background
Maxillary molar distalization is a common technique used in the non-extraction treatment of Angle Class II malocclusion that can...
Molar distalization in orthodontics: a bibliometric analysis
Molar distalization in orthodontics: a bibliometric analysis
Abstract
Objectives
The study endeavors to undertake a bibliometric analysis on molar distalization, with the objective of illuminating its evolutio...
In-plane bearing capacity analysis of concrete catenary arch with rigid skeleton: test and simulation
In-plane bearing capacity analysis of concrete catenary arch with rigid skeleton: test and simulation
Abstract
Although the rigid skeleton concrete arch has been widely used in engineering, the research on the failure mode and bearing capacity of this kind of arch is very...
Perceptual and quantitative analysis of discoloration of orthodontic elastomeric chains by food
Perceptual and quantitative analysis of discoloration of orthodontic elastomeric chains by food
AbstractBackgroundThe objectives of this study were to use a digital camera to measure the discoloration of orthodontic elastomeric chains in various immersion solutions over diffe...
STRUKTUR DRAMATIK PERTUNJUKAN DRAMA KLASIK SANGGAR TEATER MINI LAKON DEWA RUCI KAJIAN BENTUK DAN FUNGSI
STRUKTUR DRAMATIK PERTUNJUKAN DRAMA KLASIK SANGGAR TEATER MINI LAKON DEWA RUCI KAJIAN BENTUK DAN FUNGSI
ABSTRAK
Pada dasarnya nilai pendidikan karakter mempunyai tiga bagian yang saling bekaitan, yaitu pengetahuan moral, penghayatan moral dan perilaku moral. Oleh karena...
Effects of maxillary molar distalization with Zygoma-Gear Appliance
Effects of maxillary molar distalization with Zygoma-Gear Appliance
Abstract
Objective:
To evaluate the dentoalveolar, skeletal, and soft tissue effects of the Zygoma-Gear Appliance (ZGA) when used for bilateral distali...
Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
This study analyzed stress and strain mediated by 2 different implant materials, titanium (Ti) and experimental fiber-reinforced composite (FRC), on the implant and on the bone tis...
Dental Implants’ Primary and Secondary Stability Assessment according to Implant Macro-Design, Length and Width, Location, and Bone Quality.
Dental Implants’ Primary and Secondary Stability Assessment according to Implant Macro-Design, Length and Width, Location, and Bone Quality.
Some evidence supports the influence of the implant macro-design and primary stability. Additionally, tactile perception can be used to assess implant stability when placing the im...

