GW24-e1282 A noninvasive sizing method to choose fitted atrial septal defect occluder by transthoracic echocardiography in adults with secundum atrial septal defects

View through CrossRef
Objectives In our clinical practice, we try to find a feasible method to size the hole of ASD by only 2D transthoracic echocardiography (2D-TTE). It should be more practical, less expensive and without pain. Methods Sixty-seven consecutive adult patients (26 males, 41 females, mean age 38.4 ± 8.5 years) were scheduled to have ASD device closure. Before that, we calculated the size of ASD by 2D transthoracic echocardiography (2D-TTE) through parasternal four chambers view, parasternal short axes view, apical four chambers view, subcostal four chambers view and subcostal two chambers view. The biggest size from the views would be chosen for ASD device closure. Meanwhile, we paid attention to the ASD margins, and we divided them to floppy margin group (n = 24) and firm margin group (n = 43). For the floppy margin patients, we would add 2 or 4 mm more than the 2D-TTE size for preparing ASD device size. And for the firm margin patient, we chose the same 2D-TTE size for ASD device size. Results The total successful ASD device closure rate was 94.0% (63/67). The average total trans-catheter ASD closure time was 42.3 ± 12.5 minutes. ASD device closure succeeded at the first time was: 40/43 (93.0%) in the firm margin group; 16/24 (66.7%) in the floppy margin group. For the rest patient whose ASD couldn’t be closed at the first time, we reduced the size 2–5 mm in the firm margin group, the rest 3 all got successful ASD device closed. As in the floppy margin group, there were 4 patients needed adding 4–6 mm to the 2D-TTE size and then their ASD device closed successfully. There were only 4 patients (6%) in floppy margin group couldn’t be ASD device closed. For average 1.4 years follow up, only 6 patients (9.5%) had some chest pain complain, but all the devices were stable. Conclusions With our experience, the sizing based on 2D-TTE could be used for ASD device selection. The multiple views of TTE should be used to calculate the biggest size of ASD. And the margins of the ASD hole also need to be considered.
Title: GW24-e1282 A noninvasive sizing method to choose fitted atrial septal defect occluder by transthoracic echocardiography in adults with secundum atrial septal defects
Description:
Objectives In our clinical practice, we try to find a feasible method to size the hole of ASD by only 2D transthoracic echocardiography (2D-TTE).
It should be more practical, less expensive and without pain.
Methods Sixty-seven consecutive adult patients (26 males, 41 females, mean age 38.
4 ± 8.
5 years) were scheduled to have ASD device closure.
Before that, we calculated the size of ASD by 2D transthoracic echocardiography (2D-TTE) through parasternal four chambers view, parasternal short axes view, apical four chambers view, subcostal four chambers view and subcostal two chambers view.
The biggest size from the views would be chosen for ASD device closure.
Meanwhile, we paid attention to the ASD margins, and we divided them to floppy margin group (n = 24) and firm margin group (n = 43).
For the floppy margin patients, we would add 2 or 4 mm more than the 2D-TTE size for preparing ASD device size.
And for the firm margin patient, we chose the same 2D-TTE size for ASD device size.
Results The total successful ASD device closure rate was 94.
0% (63/67).
The average total trans-catheter ASD closure time was 42.
3 ± 12.
5 minutes.
ASD device closure succeeded at the first time was: 40/43 (93.
0%) in the firm margin group; 16/24 (66.
7%) in the floppy margin group.
For the rest patient whose ASD couldn’t be closed at the first time, we reduced the size 2–5 mm in the firm margin group, the rest 3 all got successful ASD device closed.
As in the floppy margin group, there were 4 patients needed adding 4–6 mm to the 2D-TTE size and then their ASD device closed successfully.
There were only 4 patients (6%) in floppy margin group couldn’t be ASD device closed.
For average 1.
4 years follow up, only 6 patients (9.
5%) had some chest pain complain, but all the devices were stable.
Conclusions With our experience, the sizing based on 2D-TTE could be used for ASD device selection.
The multiple views of TTE should be used to calculate the biggest size of ASD.
And the margins of the ASD hole also need to be considered.

Related Results

Clinical analysis on interventional treatmen for patients with ostium secundum defect
Clinical analysis on interventional treatmen for patients with ostium secundum defect
Objective To evaluate the clinical efficacy of interventional therapy for patients with ostium secundum atrial septal defect (ASD). ...
Feasibility of transcatheter device closure of secundum atrial septal defect under transthoracic echocardiography guidance.
Feasibility of transcatheter device closure of secundum atrial septal defect under transthoracic echocardiography guidance.
Objective: To determine the usefulness and safety of transthoracic echocardiography (TTE) imaging for real time guidance in transcatheter device closure of atrial septal defect (AS...
Optimal selection of cotton warp sizing parameters under system research limitation
Optimal selection of cotton warp sizing parameters under system research limitation
Warp sizing is the process of applying the sizing agents to the warp yarn to improve its weavability along with improving the economic performance of weaving. We consider a finite ...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...

Back to Top