Javascript must be enabled to continue!
GW24-e1282 A noninvasive sizing method to choose fitted atrial septal defect occluder by transthoracic echocardiography in adults with secundum atrial septal defects
View through CrossRef
Objectives
In our clinical practice, we try to find a feasible method to size the hole of ASD by only 2D transthoracic echocardiography (2D-TTE). It should be more practical, less expensive and without pain.
Methods
Sixty-seven consecutive adult patients (26 males, 41 females, mean age 38.4 ± 8.5 years) were scheduled to have ASD device closure. Before that, we calculated the size of ASD by 2D transthoracic echocardiography (2D-TTE) through parasternal four chambers view, parasternal short axes view, apical four chambers view, subcostal four chambers view and subcostal two chambers view. The biggest size from the views would be chosen for ASD device closure. Meanwhile, we paid attention to the ASD margins, and we divided them to floppy margin group (n = 24) and firm margin group (n = 43). For the floppy margin patients, we would add 2 or 4 mm more than the 2D-TTE size for preparing ASD device size. And for the firm margin patient, we chose the same 2D-TTE size for ASD device size.
Results
The total successful ASD device closure rate was 94.0% (63/67). The average total trans-catheter ASD closure time was 42.3 ± 12.5 minutes. ASD device closure succeeded at the first time was: 40/43 (93.0%) in the firm margin group; 16/24 (66.7%) in the floppy margin group. For the rest patient whose ASD couldn’t be closed at the first time, we reduced the size 2–5 mm in the firm margin group, the rest 3 all got successful ASD device closed. As in the floppy margin group, there were 4 patients needed adding 4–6 mm to the 2D-TTE size and then their ASD device closed successfully. There were only 4 patients (6%) in floppy margin group couldn’t be ASD device closed. For average 1.4 years follow up, only 6 patients (9.5%) had some chest pain complain, but all the devices were stable.
Conclusions
With our experience, the sizing based on 2D-TTE could be used for ASD device selection. The multiple views of TTE should be used to calculate the biggest size of ASD. And the margins of the ASD hole also need to be considered.
Title: GW24-e1282 A noninvasive sizing method to choose fitted atrial septal defect occluder by transthoracic echocardiography in adults with secundum atrial septal defects
Description:
Objectives
In our clinical practice, we try to find a feasible method to size the hole of ASD by only 2D transthoracic echocardiography (2D-TTE).
It should be more practical, less expensive and without pain.
Methods
Sixty-seven consecutive adult patients (26 males, 41 females, mean age 38.
4 ± 8.
5 years) were scheduled to have ASD device closure.
Before that, we calculated the size of ASD by 2D transthoracic echocardiography (2D-TTE) through parasternal four chambers view, parasternal short axes view, apical four chambers view, subcostal four chambers view and subcostal two chambers view.
The biggest size from the views would be chosen for ASD device closure.
Meanwhile, we paid attention to the ASD margins, and we divided them to floppy margin group (n = 24) and firm margin group (n = 43).
For the floppy margin patients, we would add 2 or 4 mm more than the 2D-TTE size for preparing ASD device size.
And for the firm margin patient, we chose the same 2D-TTE size for ASD device size.
Results
The total successful ASD device closure rate was 94.
0% (63/67).
The average total trans-catheter ASD closure time was 42.
3 ± 12.
5 minutes.
ASD device closure succeeded at the first time was: 40/43 (93.
0%) in the firm margin group; 16/24 (66.
7%) in the floppy margin group.
For the rest patient whose ASD couldn’t be closed at the first time, we reduced the size 2–5 mm in the firm margin group, the rest 3 all got successful ASD device closed.
As in the floppy margin group, there were 4 patients needed adding 4–6 mm to the 2D-TTE size and then their ASD device closed successfully.
There were only 4 patients (6%) in floppy margin group couldn’t be ASD device closed.
For average 1.
4 years follow up, only 6 patients (9.
5%) had some chest pain complain, but all the devices were stable.
Conclusions
With our experience, the sizing based on 2D-TTE could be used for ASD device selection.
The multiple views of TTE should be used to calculate the biggest size of ASD.
And the margins of the ASD hole also need to be considered.
Related Results
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
The clinical evaluation of transcatheter closure of perimembranous ventricular septal defects with the Amplatzer duct occluder II
The clinical evaluation of transcatheter closure of perimembranous ventricular septal defects with the Amplatzer duct occluder II
Objectives
Investigate the feasibility of perimembranous ventricular septal defects closure with the Amplatzer duct occluder II.
...
INTERVENTIONAL THERAPY OF MULTIPLE ATRIAL SEPTAL DEFECTS
INTERVENTIONAL THERAPY OF MULTIPLE ATRIAL SEPTAL DEFECTS
Objectives
To evaluate the safety and efficiency of transactheter closure of multiple atrial septal defects.
Met...
ASSA13-15-6 Transcatheter Closure of Patent Ductus Arteriosus with Severe Pulmonary Hypertension Using Domestic Occluder in Adults
ASSA13-15-6 Transcatheter Closure of Patent Ductus Arteriosus with Severe Pulmonary Hypertension Using Domestic Occluder in Adults
Background
To evaluate the clinical efficacy of transcatheter closure of patent ductus arteriosus (PDA) with severe pulmonary hypertention using domestic occluder...
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Objective: To compare the left atrial function utilising speckle tracking echocardiography in patients with low-risk and high-risk non-valvular atrial fibrillation.Methods: The des...
Individualized Strategy of Minimally Invasive Cardiac Surgery in Congenital Cardiac Septal Defects
Individualized Strategy of Minimally Invasive Cardiac Surgery in Congenital Cardiac Septal Defects
Abstract
Background: Intracardiac septal defect tends to be repaired by minimally invasive surgery in both children and adults. This study summarized our strategy of minima...
Analysis of P Wave and P Dispersion in Children with Secundum Atrial Septal Defect
Analysis of P Wave and P Dispersion in Children with Secundum Atrial Septal Defect
Background: P maximum and P dispersion are evaluated as predictors of paroxysmal atrial fibrillation in adults. In this study, these variables are being investigated in children w...
P920Understanding arrhythmia mechanisms in patients with atrial septal defects
P920Understanding arrhythmia mechanisms in patients with atrial septal defects
Abstract
Background
Atrial arrhythmias represent a major cause of morbidity and hospitalization in patients with atrial septal d...

