Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Accuracy of two electronic apex locators: in vivo and in vitro study

View through CrossRef
The present study proposed the comparison of the reading between the in vivo and in vitro models during the evaluation of Root ZX II foramen locators and Propex II. The localization of the major foramen was determined electronically in 40 canals of human single-rooted teeth in the in vivoand in vitro models. After the two measurements, the actual tooth length was measured. All values were tabulated and submitted to the statistical analysis of the data, applying the non-parametric Kruskal-Wallis test with significance level of 5% (p<0,05). Statistical analysis revealed no significant differences between the in vivo and in vitro models regarding the accuracy of the Root ZX II and Propex II devices during the localization of the major foramen. In the in vivo model, Propex II presented accuracy of 75% (±0,5mm) and 90% (±1,0mm) and Root ZX II presented accuracy of 80% (±0,5mm) and 92,5% (±1,0mm). For the in vitro model, Propex II presented accuracy of 72,5% (±0,5mm) and 97,5% (±1,0mm) and Root ZX II presented accuracy of 80% (±0,5mm) and 95% (±1,0mm). There were no statistically significant differences between the in vivo and in vitro models and between the devices used in the research.
Title: Accuracy of two electronic apex locators: in vivo and in vitro study
Description:
The present study proposed the comparison of the reading between the in vivo and in vitro models during the evaluation of Root ZX II foramen locators and Propex II.
The localization of the major foramen was determined electronically in 40 canals of human single-rooted teeth in the in vivoand in vitro models.
After the two measurements, the actual tooth length was measured.
All values were tabulated and submitted to the statistical analysis of the data, applying the non-parametric Kruskal-Wallis test with significance level of 5% (p<0,05).
Statistical analysis revealed no significant differences between the in vivo and in vitro models regarding the accuracy of the Root ZX II and Propex II devices during the localization of the major foramen.
In the in vivo model, Propex II presented accuracy of 75% (±0,5mm) and 90% (±1,0mm) and Root ZX II presented accuracy of 80% (±0,5mm) and 92,5% (±1,0mm).
For the in vitro model, Propex II presented accuracy of 72,5% (±0,5mm) and 97,5% (±1,0mm) and Root ZX II presented accuracy of 80% (±0,5mm) and 95% (±1,0mm).
There were no statistically significant differences between the in vivo and in vitro models and between the devices used in the research.

Related Results

Accuracy evaluation of three electronic apex locators in teeth with immature apices
Accuracy evaluation of three electronic apex locators in teeth with immature apices
The aim of this randomized controlled study was to evaluate the accuracy of Root ZX, iPex and YS-RZ-A apex locators in tooth with incomplete apices. Material and methods: Thirty hu...
Electronic working length determination in primary teeth by Propex and Digital Signal Processing
Electronic working length determination in primary teeth by Propex and Digital Signal Processing
AbstractThe purpose of this study was to evaluate the accuracy of electronic apex locators Digital Signal Processing (DSP) and ProPex, for root canal length determination in primar...
Use of electronic apex locator in the impossibility of radiographic visualization of the root apex: report of two cases
Use of electronic apex locator in the impossibility of radiographic visualization of the root apex: report of two cases
Electronic apex locators have been widely used for foraminal identification and for working length determination. The establishment of a correct apical limit is essential for a goo...
Working length determination
Working length determination
Introduction: Working length (WL) determination is one of the crucial steps in endodontic treatment. Conventional Apex locators (EAL) are consistently employed nowadays for WL dete...
In vitro assessment of the accuracy of three electronic apex locators
In vitro assessment of the accuracy of three electronic apex locators
Aim of this in vitro study was to compare accuracy of three electronic apex locators (EALs) (ES-02, ES-03 and ProPex) in root canals of extracted human teeth utilizing two meter re...
In vitro assessment of the accuracy of three electronic apex locators
In vitro assessment of the accuracy of three electronic apex locators
Aim of this in vitro study was to compare accuracy of three electronic apex locators (EALs) (ES-02, ES-03 and ProPex) in root canals of extracted human teeth utilizing two meter re...
Anatomical Investigation of the Cardiac Apex
Anatomical Investigation of the Cardiac Apex
Background: Understanding cardiac anatomy is the key to solve unknown issues about its function. The continuous and helical myocardial structure plays a fundamental role in its tor...
Investigación anatómica del ápex cardíaco
Investigación anatómica del ápex cardíaco
Objective: Understanding cardiac anatomy is the key to solve unknown issues about its function. The continuous and helical myocardial structure plays a fundamental role in its tors...