Javascript must be enabled to continue!
Low temperature offers better foam stability
View through CrossRef
AbstractBackgroundThe foam's structural longevity, linked to the effectiveness of sclerotherapy, depends on preparation conditions. The factors enhancing the treatment's effectiveness and efficacy are still under discussion.MethodsWe conducted an in vitro preclinical research, which included 144 independent trials. A total of 8 combinations involving 18 trials were designed according to settings of +4°C and room temperature (20–22°C), liquid‐to‐air ratios of 1/1 and 1/4, and polidocanol concentrations of 0.5% and 1% using the modified Tessari method. Our study aimed to examine the effect of air ratio, agent temperature, and polidocanol concentration on stability by assessing the foam half‐time (FHT) and defining the optimal preparation conditions.ResultsThe mean FHT was 117 ± 30.4 s. The longest FHT was in a 1:4 air‐to‐sclerosant ratio at +4°C, regardless of the sclerosant concentration (for %0.5 mean FHT: 146.2 ± 13.9 s, for % 1 mean FHT: 146.9 ± 18 s). There was a significant interaction among the three variables on FHT (p = 0.001). Temperature emerged as the primary factor (F(1, 136) = 124, p < 0.001, ηp2 = 0.477), with lower temperatures markedly enhancing the longevity (p < 0.001). Preparation at a temperature of 4°C resulted in an extended FHT of 32.5 s compared to 22°C (95% CI: 24.06–41.04 s).ConclusionThe temperature, agent concentration, and gas ratio significantly influence the stability of the physician‐compounded foam. The low temperature at +4°C may offer better FHT for sclerotherapy.
Title: Low temperature offers better foam stability
Description:
AbstractBackgroundThe foam's structural longevity, linked to the effectiveness of sclerotherapy, depends on preparation conditions.
The factors enhancing the treatment's effectiveness and efficacy are still under discussion.
MethodsWe conducted an in vitro preclinical research, which included 144 independent trials.
A total of 8 combinations involving 18 trials were designed according to settings of +4°C and room temperature (20–22°C), liquid‐to‐air ratios of 1/1 and 1/4, and polidocanol concentrations of 0.
5% and 1% using the modified Tessari method.
Our study aimed to examine the effect of air ratio, agent temperature, and polidocanol concentration on stability by assessing the foam half‐time (FHT) and defining the optimal preparation conditions.
ResultsThe mean FHT was 117 ± 30.
4 s.
The longest FHT was in a 1:4 air‐to‐sclerosant ratio at +4°C, regardless of the sclerosant concentration (for %0.
5 mean FHT: 146.
2 ± 13.
9 s, for % 1 mean FHT: 146.
9 ± 18 s).
There was a significant interaction among the three variables on FHT (p = 0.
001).
Temperature emerged as the primary factor (F(1, 136) = 124, p < 0.
001, ηp2 = 0.
477), with lower temperatures markedly enhancing the longevity (p < 0.
001).
Preparation at a temperature of 4°C resulted in an extended FHT of 32.
5 s compared to 22°C (95% CI: 24.
06–41.
04 s).
ConclusionThe temperature, agent concentration, and gas ratio significantly influence the stability of the physician‐compounded foam.
The low temperature at +4°C may offer better FHT for sclerotherapy.
Related Results
Foam Injection Test in the Siggins Field, Illinois
Foam Injection Test in the Siggins Field, Illinois
A pilot test in this tired, old field, confirmed the laboratory-derived conclusion that foam can do more than soften a beard or ruin a river. It can decrease the mobility of gas an...
Foam Flood in Yates Reservoir for Improving Oil Recovery
Foam Flood in Yates Reservoir for Improving Oil Recovery
Abstract
The Yates reservoir is a major, multibillion-barrel legacy oil reservoir in West Texas discovered in 1926. Oil production mainly comes from the San Andres f...
Pore-Scale Observation of Solvent Based Foam During Heavy Oil Recovery
Pore-Scale Observation of Solvent Based Foam During Heavy Oil Recovery
Abstract
Aqueous based foam injection has gained interest for conventional oil recovery in recent times. Foam can control the mobility ratio and improve the sweep ef...
The Adaptability Research of Steam Flooding Assisted by Nitrogen Foam in Henan Oilfield
The Adaptability Research of Steam Flooding Assisted by Nitrogen Foam in Henan Oilfield
Abstract
With the further study on foaming agent performance, steam flooding assisted by nitrogen foam has been applied more widely. But the flexibility of this t...
Foam Stability of Solvent/Surfactant/Heavy-Oil System Under Reservior Conditions
Foam Stability of Solvent/Surfactant/Heavy-Oil System Under Reservior Conditions
Abstract
Solvent-based method is an important method for recovering heavy oil. In the case of solvent flooding, its sweeping efficiency might be adversely affected b...
Approximative approach to optimize concrete foaming concentration in two stage foaming
Approximative approach to optimize concrete foaming concentration in two stage foaming
The article presents the results of a study on foam concentration for the production of foam concrete using a two-stage foam introduction method. The research was conducted by eval...
Mixture of Anionic Surfactant and Surface-Modified Silica Nanoparticles for Enhancing Foam Stability
Mixture of Anionic Surfactant and Surface-Modified Silica Nanoparticles for Enhancing Foam Stability
Abstract
Foam is one of the most promising techniques to reduce gas mobility in subsurface formations. Foamed-gas injection can reduce the mobility of gas by increas...
Mechanism Study on Foam Flooding for Daqing Reservoirs After Polymer Flooding
Mechanism Study on Foam Flooding for Daqing Reservoirs After Polymer Flooding
Abstract
Polymer flooding has been carried out widely in Daqing oilfield. The average oil recovery was 53% and the water cut was more than 90% after polymer flooding...

