Javascript must be enabled to continue!
Voltage booster scheme for enhancing the fault ride‐through of wind turbines
View through CrossRef
This study presents a new scheme for a continuously variable (CV) series braking resistor (SBR) with independent per phase controller. The CV‐SBR is a CV and not stepwise. A novelty of the work presented is that the CV‐SBR operates on the whole range of wind speeds. The proposed scheme is applicable to fault ride‐through (FRT) of fixed speed wind turbines (FSWTs). The CV‐SBR scheme is compared to the single‐step (SS) and multi‐steps (MS) SBRs. The CV‐SBR scheme is modelled and simulated in PSCAD/EMTDC™. The performance of the wind turbine is studied for balanced and unbalanced fault scenarios. The CV‐SBR scheme is advantageous over the other two candidates with its ability to limit the fault current and reduce the turbine speed deviation at any wind speed. The CV‐SBR is employed with a static synchronous compensator (STATCOM) to allow FRT of FSWT connected to weak grid during nearby faults and to deliver the reactive current required by some grid codes. The CV‐SBR scheme is successful in reducing voltage disturbance's consequences on the generator's mechanical system. Simulation results show that the CV‐SBR allows FRT of FSWT connected to weak grid where the STATCOM alone is not able to sufficiently enhance the FRT of FSWT during nearby faults.
Institution of Engineering and Technology (IET)
Title: Voltage booster scheme for enhancing the fault ride‐through of wind turbines
Description:
This study presents a new scheme for a continuously variable (CV) series braking resistor (SBR) with independent per phase controller.
The CV‐SBR is a CV and not stepwise.
A novelty of the work presented is that the CV‐SBR operates on the whole range of wind speeds.
The proposed scheme is applicable to fault ride‐through (FRT) of fixed speed wind turbines (FSWTs).
The CV‐SBR scheme is compared to the single‐step (SS) and multi‐steps (MS) SBRs.
The CV‐SBR scheme is modelled and simulated in PSCAD/EMTDC™.
The performance of the wind turbine is studied for balanced and unbalanced fault scenarios.
The CV‐SBR scheme is advantageous over the other two candidates with its ability to limit the fault current and reduce the turbine speed deviation at any wind speed.
The CV‐SBR is employed with a static synchronous compensator (STATCOM) to allow FRT of FSWT connected to weak grid during nearby faults and to deliver the reactive current required by some grid codes.
The CV‐SBR scheme is successful in reducing voltage disturbance's consequences on the generator's mechanical system.
Simulation results show that the CV‐SBR allows FRT of FSWT connected to weak grid where the STATCOM alone is not able to sufficiently enhance the FRT of FSWT during nearby faults.
Related Results
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems.
Concerning fault detection, interv...
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background:
In a wind farm, the wind speed of the downstream wind turbine will be
lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Cost effectiveness analysis comparing varying booster intervals of vaccination policies to address COVID-19 situation in Thailand, 2023
Cost effectiveness analysis comparing varying booster intervals of vaccination policies to address COVID-19 situation in Thailand, 2023
The COVID-19 booster immunization policy is cost-effective, but evidence on additional booster doses and appropriate strategies is scarce. This research compared the cost-effective...
Aerodynamics of Clustered Wind Lens Turbines
Aerodynamics of Clustered Wind Lens Turbines
Wind lens turbines, developed by Kyushu University have increased performance due to the duct surrounding the rotor [1]. A Multi rotor system is a promising concept to upscale wind...
Abstract P2-20-01: Safety and Clinical Efficacy of Multiple Booster Inoculations with the E75 Adjuvant Breast Cancer Vaccine
Abstract P2-20-01: Safety and Clinical Efficacy of Multiple Booster Inoculations with the E75 Adjuvant Breast Cancer Vaccine
Abstract
Background: We are conducting clinical trials of the HER2/neu E75-peptide+GM-CSF vaccine in clinically disease-free breast cancer patients at high risk for ...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Design and Performance Analysis of Distributed Equal Angle Spiral Vertical Axis Wind Turbine
Design and Performance Analysis of Distributed Equal Angle Spiral Vertical Axis Wind Turbine
Background:
The wind turbine is divided into a horizontal axis and a vertical axis depending
on the relative positions of the rotating shaft and the ground. The advantage of the ch...
Like Lady Godiva
Like Lady Godiva
Introducing Lady Godiva through a Fan-Historical Lens
The legend of Lady Godiva, who famously rode naked through the streets of Coventry, veiled only by her long, flowing hair, has...