CLINICAL APPLICATION OF EMERGENCY BEDSIDE TEMPORARY CARDIAC PACING WITHOUT X-RAY FLUOROSCOPY
View through CrossRef
Objectives
To investigate the clinical value and safety of emergency bedside temporary cardiac pacing without X-ray fluoroscopy.
Methods
63 patients were selected due to ventricular rate less than or equal to 40 times/min and (or) RR interval greater than 3.0 s caused by various diseases and associated with severe hemodynamic disorders, Adams syndrome attack or disturbance of consciousness. Subclavian vein was punctured for vasodilating sheath placement by seldinger technique without x-ray fluoroscopy at bedside. Temporary pacing electrode was inserted into the right ventricular cavity from the sheath and success was judged by three methods based on intracardiac ECG, pacing ECG, or whether it could induce PVCs.
Results
Out of 63 patients, 59 cases of pacing was successful and the success rate was 93.7%. The operation time from the puncture to the successful pacing was about 2–15 min (average 4.5 min) and pacing thresholds were less than or equal to 2.0 V. The hemodynamic significantly improved, Adams syndrome attacks stopped and consciousness returned to normal in successful pacing patients. No serious complications occurred such as infective endocarditis, bleeding, pneumothorax, hemothorax and so on.
Conclusions
Emergency bedside temporary cardiac pacing without x-ray fluoroscopy is important rescue of severe bradycardia or cardiac arrest, particularly suitable for critically ill patients, who should not be moved and need emergency pacing. It has fast, easy and safe advantages and is indispensable means in the cardiac emergency work.
Title: CLINICAL APPLICATION OF EMERGENCY BEDSIDE TEMPORARY CARDIAC PACING WITHOUT X-RAY FLUOROSCOPY
Description:
Objectives
To investigate the clinical value and safety of emergency bedside temporary cardiac pacing without X-ray fluoroscopy.
Methods
63 patients were selected due to ventricular rate less than or equal to 40 times/min and (or) RR interval greater than 3.
0 s caused by various diseases and associated with severe hemodynamic disorders, Adams syndrome attack or disturbance of consciousness.
Subclavian vein was punctured for vasodilating sheath placement by seldinger technique without x-ray fluoroscopy at bedside.
Temporary pacing electrode was inserted into the right ventricular cavity from the sheath and success was judged by three methods based on intracardiac ECG, pacing ECG, or whether it could induce PVCs.
Results
Out of 63 patients, 59 cases of pacing was successful and the success rate was 93.
7%.
The operation time from the puncture to the successful pacing was about 2–15 min (average 4.
5 min) and pacing thresholds were less than or equal to 2.
0 V.
The hemodynamic significantly improved, Adams syndrome attacks stopped and consciousness returned to normal in successful pacing patients.
No serious complications occurred such as infective endocarditis, bleeding, pneumothorax, hemothorax and so on.
Conclusions
Emergency bedside temporary cardiac pacing without x-ray fluoroscopy is important rescue of severe bradycardia or cardiac arrest, particularly suitable for critically ill patients, who should not be moved and need emergency pacing.
It has fast, easy and safe advantages and is indispensable means in the cardiac emergency work.
Related Results
Hemodynamic Effects of Artificial Pacing in Complete Heart Block Complicating Acute Myocardial Infarction
Hemodynamic Effects of Artificial Pacing in Complete Heart Block Complicating Acute Myocardial Infarction
The hemodynamic changes associated with complete heart block complicating acute myocardial infarction and the effects of artificial pacing at various rates on these measurements we...
e0567 Early diagnosis and rescue pericardiocentesis for acute cardiac tamponade during radiofrequency ablation for arrhythmias, Is fluoroscopy enough?
e0567 Early diagnosis and rescue pericardiocentesis for acute cardiac tamponade during radiofrequency ablation for arrhythmias, Is fluoroscopy enough?
Background
With the number of complex catheter ablation procedures increasing, procedure-related acute cardiac tamponade is encountered more frequently in the car...
Temporary Rivers
Temporary Rivers
Temporary rivers are those that do not flow continuously through time along their entire length. The phrase temporary rivers primarily came into use during the first decade of the ...
Mediator kinase submodule-dependent regulation of cardiac transcription
Mediator kinase submodule-dependent regulation of cardiac transcription
<p>Pathological cardiac remodeling results from myocardial stresses including pressure and volume overload, neurohumoral activation, myocardial infarction, and hypothyroidism...
GW24-e1773 Application of a novel pacing guide wire in cardiac resynchronisation therapy
GW24-e1773 Application of a novel pacing guide wire in cardiac resynchronisation therapy
Objectives
The implantation of left ventricular (LV) lead was the most complicated process in the cardiac resynchronisation therapy (CRT), the aim of this study w...
Non Selective his Bundle Pacing: As Physiological as S-HBP but Simpler and Faster
Non Selective his Bundle Pacing: As Physiological as S-HBP but Simpler and Faster
We have read with interest Dr. Burri’s Electrocardiographic Analysis for His Bundle Pacing at Implantation and Follow up [1]. A comprehensive guide to understand electrocardiograph...
Attitudes and practices of orthopedic surgeons when using fluoroscopy in the operating room
Attitudes and practices of orthopedic surgeons when using fluoroscopy in the operating room
Introduction: The aim of this study is to assess the practices and knowledge levels of Moroccan orthopedic surgeons on the possible uses and risks of fluoroscopy and to evaluate me...
A novel image integration technology mapping system significantly reduces radiation exposure during ablation for a wide spectrum of tachyarrhythmias in children
A novel image integration technology mapping system significantly reduces radiation exposure during ablation for a wide spectrum of tachyarrhythmias in children
ObjectiveRadiofrequency catheter ablation (RFCA) has evolved into an effective and safe technique for the treatment of tachyarrhythmia in children. Concerns about children and invo...