Javascript must be enabled to continue!
The Covid-19 Antibody Titer of Convalescence Plasma Repeated Donors at Red Cross Indonesia of Tulungagung Regency
View through CrossRef
Convalescent plasma is plasma that is already present in the body and includes anti-SARS-CoV-2 antibodies. This plasma includes antibodies that may kill viral particles, thereby preventing virus entrance into cells. This neutralizing procedure has an effect on the improvement of a patient's clinical state after receiving convalescent plasma treatment. The possibility of this convalescent plasma therapy as a treatment for individuals infected with SARS-CoV-2 has been evaluated, and clinical trials are still ongoing. The aim of this study is to determine the antibody titer of the donor. The research was a descriptive study. Total sample was 25 repeated male donors. The data of their IgM and IgG levels was obtained from Management Information System at Red Cross Indonesia Of Tulungagung Regency. Data was presented as table. The mean IgG level of repeated convalescent plasma donors is higher than the mean IgM level. The mean IgM level of repeated convalescent plasma donors is often constant. The mean IgG level of convalescent plasma donors increased through the fifth donor and then declined from the sixth to the ninth donor. The mean result of IgM and IgG has decreased by a higher proportion than it has increased.
Title: The Covid-19 Antibody Titer of Convalescence Plasma Repeated Donors at Red Cross Indonesia of Tulungagung Regency
Description:
Convalescent plasma is plasma that is already present in the body and includes anti-SARS-CoV-2 antibodies.
This plasma includes antibodies that may kill viral particles, thereby preventing virus entrance into cells.
This neutralizing procedure has an effect on the improvement of a patient's clinical state after receiving convalescent plasma treatment.
The possibility of this convalescent plasma therapy as a treatment for individuals infected with SARS-CoV-2 has been evaluated, and clinical trials are still ongoing.
The aim of this study is to determine the antibody titer of the donor.
The research was a descriptive study.
Total sample was 25 repeated male donors.
The data of their IgM and IgG levels was obtained from Management Information System at Red Cross Indonesia Of Tulungagung Regency.
Data was presented as table.
The mean IgG level of repeated convalescent plasma donors is higher than the mean IgM level.
The mean IgM level of repeated convalescent plasma donors is often constant.
The mean IgG level of convalescent plasma donors increased through the fifth donor and then declined from the sixth to the ninth donor.
The mean result of IgM and IgG has decreased by a higher proportion than it has increased.
Related Results
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
Abstract
Introduction
Human immunodeficiency virus (HIV) and Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV2) surface glycoproteins, including shared epitope motifs, sho...
The Impact of the Covid-19 Pandemic and Macroeconomics on the Sharia Stock Indexes in Indonesia
The Impact of the Covid-19 Pandemic and Macroeconomics on the Sharia Stock Indexes in Indonesia
ABSTRACT
The Covid-19 pandemic has changed economic conditions in various countries, including Indonesia. One of the sectors affected is the capital market sector which can also de...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Follow-up of 12,559 Unrelated Donors of Peripheral Blood Stem Cells or Bone Marrow
Follow-up of 12,559 Unrelated Donors of Peripheral Blood Stem Cells or Bone Marrow
Abstract
Abstract 365
Donor follow-up is indicated to detect potential long-term risks for allogeneic stem cell donors. We sent a follow-up questionna...
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAFTAR PUSTAKAAditama, M. H. R., & Selfiardy, S. (2022). Kehidupan Mahasiswa Kuliah Sambil Bekerja di Masa Pandemi Covid-19. Kidspedia: Jurnal Pendidikan Anak Usia Dini, 3(...
Infections of Hepatitis B and C and Malaria Plasmodium Falciparum among Blood Donors in Ife East Local Government Area, Ile Ife, Osun State, Nigeria
Infections of Hepatitis B and C and Malaria Plasmodium Falciparum among Blood Donors in Ife East Local Government Area, Ile Ife, Osun State, Nigeria
Endemic regions for malaria are endemic for other infectious diseases that might affect the malaria infection. Infection with
hepatitis B virus (HBV) and hepatitis C virus (HCV) ar...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract
Introduction
Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...

