Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Conceptual Framework for the Development of an Air Quality Monitoring Station in Denton, Texas

View through CrossRef
Denton, Texas consistently reaches ozone nonattainment levels. This has led to a large focus of air pollution monitoring efforts in the region, with long-range transport being explored as a key contributor. For this study, the University of North Texas Discovery Park campus was chosen as a prospective location for an extensive air quality monitoring station. Sixteen years of ozone and meteorological data for five state-run monitoring sites within a 25 mile radius, including the nearest Denton Airport site, was gathered from TCEQ online database for the month of April for the years 2000 to 2015. The data was analyzed to show a historical, regional perspective of ozone near the proposed site. The maximum ozone concentration measured at the Denton Airport location over the 16 year period was measured at 96 ppb in 2001. Experimental ozone and meteorological measurements were collected at the Discovery Park location from March 26 to April 3 and April 8 to April, 2016 and compared to the Denton Airport monitoring site. A time lag in ozone trends and an increase in peak ozone concentrations at the proposed location were observed at the proposed site in comparison to the Denton Airport site. Historical and experimental meteorological data agreed in indicating that southern winds that rarely exceed 20 miles per hour are the predominant wind pattern. Back trajectories, wind roses, pollution roses, and bivariate plots created for peak ozone days during experimental periods support long range transport as a considerable cause of high ozone levels in Denton. Furthermore, a study of the precursor characteristics at the Denton Airport site indicated the site was being affected by a local source of nitrogen dioxide that was not affecting the proposed location. The differences in the Denton Airport site and the proposed site indicate that further monitoring at Discovery Park would be insightful. An outline of an expansive mobile monitoring station and suggestions for effective utilization are provided to guide future studies in Denton and the surrounding North Texas region.
University of North Texas Libraries
Title: Conceptual Framework for the Development of an Air Quality Monitoring Station in Denton, Texas
Description:
Denton, Texas consistently reaches ozone nonattainment levels.
This has led to a large focus of air pollution monitoring efforts in the region, with long-range transport being explored as a key contributor.
For this study, the University of North Texas Discovery Park campus was chosen as a prospective location for an extensive air quality monitoring station.
Sixteen years of ozone and meteorological data for five state-run monitoring sites within a 25 mile radius, including the nearest Denton Airport site, was gathered from TCEQ online database for the month of April for the years 2000 to 2015.
The data was analyzed to show a historical, regional perspective of ozone near the proposed site.
The maximum ozone concentration measured at the Denton Airport location over the 16 year period was measured at 96 ppb in 2001.
Experimental ozone and meteorological measurements were collected at the Discovery Park location from March 26 to April 3 and April 8 to April, 2016 and compared to the Denton Airport monitoring site.
A time lag in ozone trends and an increase in peak ozone concentrations at the proposed location were observed at the proposed site in comparison to the Denton Airport site.
Historical and experimental meteorological data agreed in indicating that southern winds that rarely exceed 20 miles per hour are the predominant wind pattern.
Back trajectories, wind roses, pollution roses, and bivariate plots created for peak ozone days during experimental periods support long range transport as a considerable cause of high ozone levels in Denton.
Furthermore, a study of the precursor characteristics at the Denton Airport site indicated the site was being affected by a local source of nitrogen dioxide that was not affecting the proposed location.
The differences in the Denton Airport site and the proposed site indicate that further monitoring at Discovery Park would be insightful.
An outline of an expansive mobile monitoring station and suggestions for effective utilization are provided to guide future studies in Denton and the surrounding North Texas region.

Related Results

Crafting Downtown Denton: An Exploration of Craft Beer Consumption as an Activity in Denton, Texas
Crafting Downtown Denton: An Exploration of Craft Beer Consumption as an Activity in Denton, Texas
Craft beer as a cultural phenomenon coincided with the revitalization of downtown Denton, Texas. Much of the existing literature on craft beer and its relation to place focuses on ...
Some Soundwalks (Denton, Tx)
Some Soundwalks (Denton, Tx)
some soundwalks (Denton, TX) is an audio portrait of the Denton square - the area in downtown Denton bordered by the streets Oak, Hickory, Elm, and Locust. For three months (June -...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Analysis of the Response Law of Station Buried Depth Change to Subway Station Under Vibration Load
Analysis of the Response Law of Station Buried Depth Change to Subway Station Under Vibration Load
In the period of rapid development of urban rail transit, the traditional transportation hub has become increasingly unable to meet the needs of people 's travel due to the lack of...
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Permafrost is a thermal phenomenon, defined as subsurface material with a temperature remaining below 0°C for at least two consecutive years. Permafrost occurs at high latitudes an...
Study of Honeycomb Air Curtain for a Freezer Room to Enhance Protection against Warm Air Infiltration
Study of Honeycomb Air Curtain for a Freezer Room to Enhance Protection against Warm Air Infiltration
The objective of this research is to present the energy-saving effect of applying an air curtain to prevent the penetration of warm air through a freezer door. Retail business is h...
ZONASI INTRUSI AIR ASIN DENGAN KUALITAS FISIK AIR TANAH DI KOTA SEMARANG
ZONASI INTRUSI AIR ASIN DENGAN KUALITAS FISIK AIR TANAH DI KOTA SEMARANG
Air tanah sering digunakan sebagai sumberdaya air untuk keperluan air bersih dan air minum. Kebutuhan air tanah di kota-kota besar seperti kota Semarang terus meningkat seiring den...

Back to Top