Javascript must be enabled to continue!
Gaseous Micro-Embolic Activity and Goal-Directed Perfusion Management in a Closed System for Cardiopulmonary Bypass and Minimally Invasive Extracorporeal Circulation during Coronary Artery Bypass Grafting
View through CrossRef
Background: Cardiopulmonary bypass (CPB) techniques are becoming minimally invasive in clinical practice. The literature describes various extracorporeal techniques which seek to eliminate air-blood contact and reduce both hemodilution and the contact surface such as in Minimally invasive Extracorporeal Circulation (MiECC) and closed systems for CPB. However, the delivery of micro-embolic activity in the circuit and metabolic activity in terms of oxygen delivery for Goal-Directed Perfusion (GDP) management, in relation to the patient's blood volume and central venous pressure, have never been related and correlated. In this report, we present a cohort study that investigated these aspects between the closed SVR2000 System and modular MiECC (both from Eurosets SRL, Medolla, Italy). Materials and Methods: Data were collected retrospectively and used to compare 60 consecutive patients who underwent isolated coronary artery bypass grafting (CABG) surgery by two surgeons using an SVR2000 oxygenator in 30 procedures, with a matched cohort of patients from the same period who underwent isolated CABG surgery by two other surgeons using a modular MiECC in 30 procedures. The primary endpoints collected were data on micro-embolic activity, including the number of gaseous micro-emboli in the circuit during the procedure, the mean maintenance value of oxygen delivery (DO2) and data relating to venous return volume and central venous pressure (CVP). Results: During the CPB procedures, the following values were recorded for the closed SVR2000 and MiECC groups, respectively: the average number of gaseous micro-emboli (GME) in the venous line, 833 ± 23 vs 1221 ± 45 (p = 0.028); GME in the outlet of the pump, 375 ± 45 vs 429 ± 76 (p = 0.89; GME in the arterial line, 189 ± 36 vs 205 ± 27 (p = 0.92), and the volume of GME in the arterial line (mL), 0.32± 12 vs 0.49± 17 (p = 0.93). The mean Indexed Oxygen Delivery (DO2i) during cross-clamp (ml/min/m2) was 319 ±12 vs 278 ±9 (p = 0.0019), respectively. The maximum mean volume of venous return in the soft-shell venous reservoir (ml) was 1801 ±128 vs 824 ±192 (p = 0.038). The mean central venous pressure (CVP) during cross-clamp (mmHg) was 0 ± 2 vs 6 ± 2 (p = 0.019). Conclusions: In this study, the results in the closed SVR2000 group were not statistically inferior to those in the modular MiECC group in terms of gaseous micro-embolic activity during CPB. Our analysis showed an important reduction of GME delivery in both systems. The closed SVR2000 group showed better management for GDP in terms of DO2i, associated with the flexibility of dynamic volume management and the absence of cavitation and regulation of the rate per minute and pump flow, which were reported in the MiECC group. The SVR2000 and modular MiECC systems were both safe and effective in perioperative practice without iatrogenic problems.
Surgical Technology Online
Title: Gaseous Micro-Embolic Activity and Goal-Directed Perfusion Management in a Closed System for Cardiopulmonary Bypass and Minimally Invasive Extracorporeal Circulation during Coronary Artery Bypass Grafting
Description:
Background: Cardiopulmonary bypass (CPB) techniques are becoming minimally invasive in clinical practice.
The literature describes various extracorporeal techniques which seek to eliminate air-blood contact and reduce both hemodilution and the contact surface such as in Minimally invasive Extracorporeal Circulation (MiECC) and closed systems for CPB.
However, the delivery of micro-embolic activity in the circuit and metabolic activity in terms of oxygen delivery for Goal-Directed Perfusion (GDP) management, in relation to the patient's blood volume and central venous pressure, have never been related and correlated.
In this report, we present a cohort study that investigated these aspects between the closed SVR2000 System and modular MiECC (both from Eurosets SRL, Medolla, Italy).
Materials and Methods: Data were collected retrospectively and used to compare 60 consecutive patients who underwent isolated coronary artery bypass grafting (CABG) surgery by two surgeons using an SVR2000 oxygenator in 30 procedures, with a matched cohort of patients from the same period who underwent isolated CABG surgery by two other surgeons using a modular MiECC in 30 procedures.
The primary endpoints collected were data on micro-embolic activity, including the number of gaseous micro-emboli in the circuit during the procedure, the mean maintenance value of oxygen delivery (DO2) and data relating to venous return volume and central venous pressure (CVP).
Results: During the CPB procedures, the following values were recorded for the closed SVR2000 and MiECC groups, respectively: the average number of gaseous micro-emboli (GME) in the venous line, 833 ± 23 vs 1221 ± 45 (p = 0.
028); GME in the outlet of the pump, 375 ± 45 vs 429 ± 76 (p = 0.
89; GME in the arterial line, 189 ± 36 vs 205 ± 27 (p = 0.
92), and the volume of GME in the arterial line (mL), 0.
32± 12 vs 0.
49± 17 (p = 0.
93).
The mean Indexed Oxygen Delivery (DO2i) during cross-clamp (ml/min/m2) was 319 ±12 vs 278 ±9 (p = 0.
0019), respectively.
The maximum mean volume of venous return in the soft-shell venous reservoir (ml) was 1801 ±128 vs 824 ±192 (p = 0.
038).
The mean central venous pressure (CVP) during cross-clamp (mmHg) was 0 ± 2 vs 6 ± 2 (p = 0.
019).
Conclusions: In this study, the results in the closed SVR2000 group were not statistically inferior to those in the modular MiECC group in terms of gaseous micro-embolic activity during CPB.
Our analysis showed an important reduction of GME delivery in both systems.
The closed SVR2000 group showed better management for GDP in terms of DO2i, associated with the flexibility of dynamic volume management and the absence of cavitation and regulation of the rate per minute and pump flow, which were reported in the MiECC group.
The SVR2000 and modular MiECC systems were both safe and effective in perioperative practice without iatrogenic problems.
Related Results
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
A study on risk factors of coronary artery disease in Chong Qing city
A study on risk factors of coronary artery disease in Chong Qing city
Objective
To investigate the relationship between risk factors and coronary artery disease in Chong Qing city, and to provide scientific basis for preventing and ...
Controversy in Managing Coronary Artery Anomaly with Co-Existing Coronary Artery Atherosclerosis in a Young
Controversy in Managing Coronary Artery Anomaly with Co-Existing Coronary Artery Atherosclerosis in a Young
We read the case report by Singh at al. with interest [1]. They present a case of a 34-year-old hypertensive man with symptomatic 3 vessel coronary artery disease on invasive coron...
Clinical Outcomes of Concomitant Coronary Artery Bypass Grafting During Ventricular Septal Myectomy
Clinical Outcomes of Concomitant Coronary Artery Bypass Grafting During Ventricular Septal Myectomy
Background
The clinical characteristics and survival outcomes of patients who underwent concomitant coronary artery bypass grafting during septal myectomy have not been...
The outcomes of concomitant off-pump coronary artery bypass grafting and pulmonary operations
The outcomes of concomitant off-pump coronary artery bypass grafting and pulmonary operations
Background: This study aims to analyze the early- and long-term outcomes of concomitant off-pump coronary artery bypass grafting and pulmonary resection for lung cancer or a thorac...
The effects of transcatheter closure of coronary-pulmonary arterial fistulas in adults
The effects of transcatheter closure of coronary-pulmonary arterial fistulas in adults
Objective
Congenital coronary artery fistula (CAF) is an extremely rare congenital anomaly of the coronary artery. We report our experience with Tran catheter occ...
Prevalence of Coronary Artery Anomalies in 12,457 Adult Patients Who Underwent Coronary Angiography
Prevalence of Coronary Artery Anomalies in 12,457 Adult Patients Who Underwent Coronary Angiography
AbstractBackgroundCoronary artery anomalies are found in 0.2% to 1.3% of patients undergoing coronary angiography and 0.3% of an autopsy series. We aimed to estimate the frequency ...