Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Perbandingan Aktivitas Enzim Cholinesterase Serum dengan Metode Fotometri Teknik Sample Start dan Substrat Start

View through CrossRef
Cholinesterase examination related to liver function and carried out by kinetic photometric method with two type reagent addition techniques, namely sample start and substrat start. Both techniques are related to incubation time during examination which affects waiting time for laboratory service result. This study aims to determine comparison of serum cholinesterase activity measured by sample start and substrat start techniques. The research was conducted in May 2024 at Clinical Chemistry Laboratory of Bandung Polytechnic Health. The research using Paired Sample T-test of 30 serum samples measured cholinesterase activity at 405 nm wavelength photometer using sample start and substrat start techniques so that 60 research data were obtained. The result of Paired Sample T-test showed that serum cholinesterase activity with sample start technique had lower trend value than serum cholinesterase activity with substrat start technique and there was no clinical effect with an analytical difference in cholinesterase activity measured by both techniques indicated by the Sig value 0.000 and TE% < TEa% that 4.72% < 8.7%. Therefore, the sample start and substrat start techniques in photometric method of serum cholinesterase activity can be applied for daily testing because the difference in value of two techniques has no clinical effect.
Title: Perbandingan Aktivitas Enzim Cholinesterase Serum dengan Metode Fotometri Teknik Sample Start dan Substrat Start
Description:
Cholinesterase examination related to liver function and carried out by kinetic photometric method with two type reagent addition techniques, namely sample start and substrat start.
Both techniques are related to incubation time during examination which affects waiting time for laboratory service result.
This study aims to determine comparison of serum cholinesterase activity measured by sample start and substrat start techniques.
The research was conducted in May 2024 at Clinical Chemistry Laboratory of Bandung Polytechnic Health.
The research using Paired Sample T-test of 30 serum samples measured cholinesterase activity at 405 nm wavelength photometer using sample start and substrat start techniques so that 60 research data were obtained.
The result of Paired Sample T-test showed that serum cholinesterase activity with sample start technique had lower trend value than serum cholinesterase activity with substrat start technique and there was no clinical effect with an analytical difference in cholinesterase activity measured by both techniques indicated by the Sig value 0.
000 and TE% < TEa% that 4.
72% < 8.
7%.
Therefore, the sample start and substrat start techniques in photometric method of serum cholinesterase activity can be applied for daily testing because the difference in value of two techniques has no clinical effect.

Related Results

Reduced Serum Cholinesterase Activity Distinguishes Hepatic Encephalopathy From 48 Types of Human Diseases
Reduced Serum Cholinesterase Activity Distinguishes Hepatic Encephalopathy From 48 Types of Human Diseases
Abstract Background: Hepatic encephalopathy is a complication of central nervous systems due to liver failure-related brain inflammation. Less than half of patients sufferi...
Production of Lipase Enzyme by Marine Actinobacteria With Various pH and Temperature
Production of Lipase Enzyme by Marine Actinobacteria With Various pH and Temperature
Abstract: The demand for enzymes as biocatalysts in industry is very high. Research and development of different types of enzymes from different sources has started. One very impor...
Pengaruh Pemberian Kombinasi Pakan Fermentasi dengan Multi Enzim dan Vitamin E dalam Ransum terhadap Peningkatan Kualitas Semen Ayam Arab
Pengaruh Pemberian Kombinasi Pakan Fermentasi dengan Multi Enzim dan Vitamin E dalam Ransum terhadap Peningkatan Kualitas Semen Ayam Arab
ABSTRAK. Penelitian ini bertujuan mempelajari pengaruh pemberian kombinasi pakan fermentasi dengan multi enzim pencernaan dan vitamin E dalam ransum komersial terhadap peningkatan ...
DEMENSI BUDAYA LOKAL DALAM TRADISI HAUL DAN MAULIDAN BAGI KOMUNITAS SEKARBELA MATARAM
DEMENSI BUDAYA LOKAL DALAM TRADISI HAUL DAN MAULIDAN BAGI KOMUNITAS SEKARBELA MATARAM
<p>Penelitian ini dilakukan di Kotamadya<br />Mataram Nusa Tenggara Barat. Sasaran<br />penelitian adalah suatu masyarakat lokal yang<br />menamakan dirinya...
Performa Ayam Kampung Super yang Diberi Ransum Dengan Level Protein dan Enzim Berbeda
Performa Ayam Kampung Super yang Diberi Ransum Dengan Level Protein dan Enzim Berbeda
Penelitian ini bertujuan untuk mengetahui performa ayam kampung super yang diberi ransum dengan penggunaan level protein dan enzim berbeda. Rancangan yang digunakan dalam penelitia...

Back to Top