Study on the Indoor Air Quality of Seoul Metropolitan Subway during the Rush Hour
View through CrossRef
With increasing interest in indoor air quality (IAQ), the recommended standards for the IAQ of public transportation were established in 2003 in Hong Kong and in 2007 in Korea. According to the recommended standards on the IAQ of public transportation of both Hong Kong and Korea, the air quality in the passenger cabins of railway vehicles may be improved through the ventilation system using outside air. Also, it is reasonable to use the carbon dioxide (CO
2
) level as the index of improvement. The Korean guidelines on the air quality in cabins include the recommended standard for particulate matter <10 μm (PM
10
) as well as CO
2
. In this study, the levels of CO
2
and PM
10
were continuously measured in the subways operated in the Seoul metropolitan area and the number of passengers using subway vehicles was surveyed based on the lines in operation and each stopping station. In addition to CO
2
and PM
10
levels, the temperature and moisture (RH%) in the passenger cabins were also measured. The average CO
2
and PM
10
levels for each line were compared with the recommended levels of cabin air quality. The correlation analysis to the number of passengers proved that the CO
2
level was linearly correlated with the number of passengers. The average CO
2
level and PM
10
level in the subway trains in the metropolitan area were found to be below that recommended in the air quality standards for cabins.
SAGE Publications
Title: Study on the Indoor Air Quality of Seoul Metropolitan Subway during the Rush Hour
Description:
With increasing interest in indoor air quality (IAQ), the recommended standards for the IAQ of public transportation were established in 2003 in Hong Kong and in 2007 in Korea.
According to the recommended standards on the IAQ of public transportation of both Hong Kong and Korea, the air quality in the passenger cabins of railway vehicles may be improved through the ventilation system using outside air.
Also, it is reasonable to use the carbon dioxide (CO
2
) level as the index of improvement.
The Korean guidelines on the air quality in cabins include the recommended standard for particulate matter <10 μm (PM
10
) as well as CO
2
.
In this study, the levels of CO
2
and PM
10
were continuously measured in the subways operated in the Seoul metropolitan area and the number of passengers using subway vehicles was surveyed based on the lines in operation and each stopping station.
In addition to CO
2
and PM
10
levels, the temperature and moisture (RH%) in the passenger cabins were also measured.
The average CO
2
and PM
10
levels for each line were compared with the recommended levels of cabin air quality.
The correlation analysis to the number of passengers proved that the CO
2
level was linearly correlated with the number of passengers.
The average CO
2
level and PM
10
level in the subway trains in the metropolitan area were found to be below that recommended in the air quality standards for cabins.
Related Results
Radiological Assessment of Hip Fracture Union RUSH and Modified RUSH
Radiological Assessment of Hip Fracture Union RUSH and Modified RUSH
Abstract
Objective:Intertrochanteric fracture is a common senile disease, which is mainly treated by surgery. The evaluation of postoperative healing of such fractures has ...
Track vibration sequence anomaly detection algorithm based on LSTM
Track vibration sequence anomaly detection algorithm based on LSTM
Subway structure monitoring obtains structure monitoring data in real time, and the obtained subway track vibration sequence exhibits obvious time series characteristics. Therefore...
Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
The elderly residing in nursing homes are typically more advanced in age, have more health issues, and spend more time indoors than other elderly people. This study explored the in...
Particle removal performance of a novel ESP type air cleaning system for indoor air quality in a subway station
Particle removal performance of a novel ESP type air cleaning system for indoor air quality in a subway station
Abstract
A novel electrostatic precipitation type air cleaning technology with near zero ozone emission for indoor air quality of a subway station was developed. To ...
Indoor and outdoor air quality relationships modelling
Indoor and outdoor air quality relationships modelling
Particulate matter (PM) related ambient pollution has emerged as one of the most significant environmental and human health issues during the last decades. Thus, ambient PM concent...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Impact of subway shield tunnel construction on deformation of existing utility tunnel
Impact of subway shield tunnel construction on deformation of existing utility tunnel
In recent years, the development of urban underground space in China, especially the construction and operation of subway tunnels, has greatly relieved the pressure of urban traffi...
The Dual-Attention Mechanism-Based Subway Station Crowded Crowds Counting Method
The Dual-Attention Mechanism-Based Subway Station Crowded Crowds Counting Method
Abstract
The subway station is an important place for passenger flow distribution in subway networks, and real-time monitoring of passenger flow within stations helps promo...