NUMERICAL ANALYSIS OF TUNNEL LED LIGHTING MAINTENANCE FACTOR
View through CrossRef
ABSTRACT: It is necessary to periodically maintain lighting equipment in accordance with international standards. Contamination of lamps caused by long-term use of lighting equipment will result in loss of Luminous Flux and optical losses. The decrease in lighting performance poses a visual difficulty for drivers and causes accidents. In this study, the total Maintenance Factor is numerically examined by considering the losses of diffuser and lens for LED lamps used in tunnel lighting. The variation of luminaries performance with years considering Maintenance Factors as regards environmental conditions and features of the luminaries is evaluated to demonstrate the importance of tunnel lighting maintenance. Moreover, to show the importance of LED lamps Maintenance Factor, the variation of illumination levels of LED lamps is analysed under different Maintenance Factors. It is observed that enhancing Maintenance Factor would contribute to energy efficiency.
ABSTRAK: Penjagaan peralatan cahaya secara berkala mengikut piawai kebangsaan adalah amat penting. Pencemaran lampu disebabkan penggunaan peralatan cahaya pada jangka panjang akan menyebabkan kehilangan kilauan kerdipan lampu dan optik. Pengurangan pencahayaan ini menyebabkan kesukaran pandangan pada pemandu dan menyebabkan kemalangan jiwa. Kajian ini mengkaji tentang jumlah Faktor Penjagaan secara numerik dengan mengambil kira pengurangan difuser dan kanta pada lampu LED yang digunakan dalam terowong pencahayaan. Faktor Penjagaan pada perubahan kilauan berdasarkan tahun mengambil kira keadaan sekeliling dan ciri khas kilauan. Tambahan, ini dinilai bagi menunjukkan kepentingan penjagaan terowong pencahayaan dan kepentingan Faktor Penjagaan Lampu LED. Perubahan pada tahap terang pada lampu LED dikaji dengan mengambil kira Faktor Penjagaan. Peningkatan pada Faktor Penjagaan telah didapati dapat menjimatkan tenaga.
Title: NUMERICAL ANALYSIS OF TUNNEL LED LIGHTING MAINTENANCE FACTOR
Description:
ABSTRACT: It is necessary to periodically maintain lighting equipment in accordance with international standards.
Contamination of lamps caused by long-term use of lighting equipment will result in loss of Luminous Flux and optical losses.
The decrease in lighting performance poses a visual difficulty for drivers and causes accidents.
In this study, the total Maintenance Factor is numerically examined by considering the losses of diffuser and lens for LED lamps used in tunnel lighting.
The variation of luminaries performance with years considering Maintenance Factors as regards environmental conditions and features of the luminaries is evaluated to demonstrate the importance of tunnel lighting maintenance.
Moreover, to show the importance of LED lamps Maintenance Factor, the variation of illumination levels of LED lamps is analysed under different Maintenance Factors.
It is observed that enhancing Maintenance Factor would contribute to energy efficiency.
ABSTRAK: Penjagaan peralatan cahaya secara berkala mengikut piawai kebangsaan adalah amat penting.
Pencemaran lampu disebabkan penggunaan peralatan cahaya pada jangka panjang akan menyebabkan kehilangan kilauan kerdipan lampu dan optik.
Pengurangan pencahayaan ini menyebabkan kesukaran pandangan pada pemandu dan menyebabkan kemalangan jiwa.
Kajian ini mengkaji tentang jumlah Faktor Penjagaan secara numerik dengan mengambil kira pengurangan difuser dan kanta pada lampu LED yang digunakan dalam terowong pencahayaan.
Faktor Penjagaan pada perubahan kilauan berdasarkan tahun mengambil kira keadaan sekeliling dan ciri khas kilauan.
Tambahan, ini dinilai bagi menunjukkan kepentingan penjagaan terowong pencahayaan dan kepentingan Faktor Penjagaan Lampu LED.
Perubahan pada tahap terang pada lampu LED dikaji dengan mengambil kira Faktor Penjagaan.
Peningkatan pada Faktor Penjagaan telah didapati dapat menjimatkan tenaga.
Related Results
Deformation and Failure Mode Analysis of the Tunnel Structure Based on the Tunnel-Related Landslides Cases
Deformation and Failure Mode Analysis of the Tunnel Structure Based on the Tunnel-Related Landslides Cases
When the tunnel passes through the slope area, once the slope stability changes or landslide disasters occur, large additional stress, deformation, or cracking are easily caused in...
Influence of Lower Double-Track Tunnel Spacing on the Stress and Deformation Characteristics of Upper Tunnel in Double-Level Condominium Tunnels
Influence of Lower Double-Track Tunnel Spacing on the Stress and Deformation Characteristics of Upper Tunnel in Double-Level Condominium Tunnels
The open-cut tunnels in Aixi Lake, Nanchang, are constructed in a condominium form of highway tunnel and subway tunnel, which are the first superimposed double-level tunnels in Chi...
The Effect of Intersection Angle on the Failure Mechanism of Utility Tunnel
The Effect of Intersection Angle on the Failure Mechanism of Utility Tunnel
Planning utility tunnel network in the area with geological disasters poses serious concerns, especial for the utility tunnel built in the ground fissures developed cities. Many pr...
Optimal Knee Flexion Angle for ACL Femoral Tunnel Drilling and ALL Femoral Tunnel Orientation in Combined ACL and ALL Reconstruction: 3D Simulation Study
Optimal Knee Flexion Angle for ACL Femoral Tunnel Drilling and ALL Femoral Tunnel Orientation in Combined ACL and ALL Reconstruction: 3D Simulation Study
Background:
In combined anterior cruciate ligament (ACL) and anterolateral ligament (ALL) reconstruction, there is a risk of collision between the femoral tunnels of th...
Structural response of precast concrete segmental tunnel linings
Structural response of precast concrete segmental tunnel linings
The increasing use of the tunnel boring machines (TBMs) has entailed their own evolution and the improvement of the construction processes applied, allowing the construction of tun...
Is part‐night lighting an effective measure to limit the impacts of artificial lighting on bats?
Is part‐night lighting an effective measure to limit the impacts of artificial lighting on bats?
AbstractAs light pollution is currently considered to be a major threat to biodiversity, different lighting management options are being explored to mitigate the impact of artifici...
Evaluation of Roadway High-Mast Tower Lighting
Evaluation of Roadway High-Mast Tower Lighting
This study conducted an evaluation of high-mast roadway lighting, which included a review of Illinois Department of Transportation’s high-mast lighting specification and a field ex...
OCCUPANTS’ PERSONALIZED PREFERENCE FOR INDOOR THERMAL AND LIGHTING ENVIRONMENT OF OFFICE BUILDINGS: A CASE STUDY BASED UTILITY FUNCTION AND BAYESIAN INFERENCE
OCCUPANTS’ PERSONALIZED PREFERENCE FOR INDOOR THERMAL AND LIGHTING ENVIRONMENT OF OFFICE BUILDINGS: A CASE STUDY BASED UTILITY FUNCTION AND BAYESIAN INFERENCE
ABSTRACT
Building thermal and lighting environment is a key concern in the construction industry. To study the personalized preferences of thermal and lighting environments...