Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Theoretical and Experimental Vibration Generation in a Coaxial Pulse-Tube Cryocooler

View through CrossRef
The microphonic noise induced by the vibration from cryocoolers has been found to cause energy resolution degradation in vibration-sensitive instruments. In this paper, theoretical and experimental research on the vibration generation mechanism of an aerospace-grade coaxial pulse-tube cryocooler (CPTC) is presented. Accordingly, suggestions for suppressing the vibration of the pulse-tube cryocooler are provided. A vibration model for the Oxford-type dual-opposed linear compressor is established, and the mechanism of vibration induced by the compressor is theoretically analyzed. A numerical simulation indicates that deviations in the compressor’s inductance coefficient, electromagnetic force coefficient, and flexure spring stiffness coefficient significantly affect the axial vibration of the compressor. The theoretical and experimental studies show that the high-order harmonic vibrations of the compressor are determined by both the resonance of the flexure springs and the high-order harmonics of the driving power supply. Through experiments and simulations, it is revealed that the dynamic gas pressure only induces vibration axially at the cold tip, while the radial vibration at the cold tip is determined by the heat head ‘s vibration and the structural response characteristics of the cold finger.
Title: Theoretical and Experimental Vibration Generation in a Coaxial Pulse-Tube Cryocooler
Description:
The microphonic noise induced by the vibration from cryocoolers has been found to cause energy resolution degradation in vibration-sensitive instruments.
In this paper, theoretical and experimental research on the vibration generation mechanism of an aerospace-grade coaxial pulse-tube cryocooler (CPTC) is presented.
Accordingly, suggestions for suppressing the vibration of the pulse-tube cryocooler are provided.
A vibration model for the Oxford-type dual-opposed linear compressor is established, and the mechanism of vibration induced by the compressor is theoretically analyzed.
A numerical simulation indicates that deviations in the compressor’s inductance coefficient, electromagnetic force coefficient, and flexure spring stiffness coefficient significantly affect the axial vibration of the compressor.
The theoretical and experimental studies show that the high-order harmonic vibrations of the compressor are determined by both the resonance of the flexure springs and the high-order harmonics of the driving power supply.
Through experiments and simulations, it is revealed that the dynamic gas pressure only induces vibration axially at the cold tip, while the radial vibration at the cold tip is determined by the heat head ‘s vibration and the structural response characteristics of the cold finger.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
The coaxial mixers composed of a high-speed central impeller and a low-speed anchor have been recommended by the previous researchers for the mixing of highly viscous and non-Newto...
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
The coaxial mixers composed of a high-speed central impeller and a low-speed anchor have been recommended by the previous researchers for the mixing of highly viscous and non-Newto...
Tube Shunt Related Complications in Pediatrics
Tube Shunt Related Complications in Pediatrics
Although medical therapy is usually an excellent therapeutic option in the adult population, in children it is often ineffective or associated with an undesirable risk:benefit rati...
Experimental and Numerical Study on Flow-Induced Vibration of PWR Steam Generator U-Tubes
Experimental and Numerical Study on Flow-Induced Vibration of PWR Steam Generator U-Tubes
The flow-induced vibration (FIV) of steam generators (SGs) in pressurized water reactors (PWRs) is a significant problem in the design process. This problem contains issues such as...
Liquid CO2 Phase Change Fracturing and Vibration Monitoring in Roadbed Slope Excavation
Liquid CO2 Phase Change Fracturing and Vibration Monitoring in Roadbed Slope Excavation
Abstract In order to analyze the vibration impact of carbon dioxide fracturing tube blasting red sandstone, combined with the engineering conditions and surrounding ...
Research on acoustic control of coupled vibration system of transducers using acoustic surface and topological defect structures
Research on acoustic control of coupled vibration system of transducers using acoustic surface and topological defect structures
<sec>How to regulate the sound waves in the coupled vibration system of complex power ultrasonic transducers and design high-performance transducer systems has always been an...

Back to Top