Javascript must be enabled to continue!
Clamping Force Evaluation of a Bolted Joint According to the Variation of Torque and Angle Applied
View through CrossRef
<div class="section abstract">Bolted joints are frequently applied in the automotive industry. Although apparent simplicity for this clamping solution, phenomena involved in the tightening procedure of the bolt are complex and very difficult to control in a production line. During the tightening process, portion of the energy is dissipated as friction and portion is consumed in elastic and plastic deformation of the bolted joint. In order to ensure the function of the joint requirements, only the second one is relevant. The problem is that the tightening process control method only monitors the "torque and angle" variables and not directly the deformation of the joint. Therefore, the monitoring is also dependent of the friction's variable, whose influence is very significant. This work aims to evaluate the clamping force behavior of a bolted joint used at small car front suspension subframe, using a transducer built with eight linear strain gauges. Ninety assemblies were controlled and the results were evaluated statistically and discussed here. </div>
SAE International
Title: Clamping Force Evaluation of a Bolted Joint According to the Variation of Torque and Angle Applied
Description:
<div class="section abstract">Bolted joints are frequently applied in the automotive industry.
Although apparent simplicity for this clamping solution, phenomena involved in the tightening procedure of the bolt are complex and very difficult to control in a production line.
During the tightening process, portion of the energy is dissipated as friction and portion is consumed in elastic and plastic deformation of the bolted joint.
In order to ensure the function of the joint requirements, only the second one is relevant.
The problem is that the tightening process control method only monitors the "torque and angle" variables and not directly the deformation of the joint.
Therefore, the monitoring is also dependent of the friction's variable, whose influence is very significant.
This work aims to evaluate the clamping force behavior of a bolted joint used at small car front suspension subframe, using a transducer built with eight linear strain gauges.
Ninety assemblies were controlled and the results were evaluated statistically and discussed here.
</div>.
Related Results
Design and experiment of flexible clamping device for pepper plug seedlings
Design and experiment of flexible clamping device for pepper plug seedlings
At present, there are leakage and injury of pepper seedlings in the process of seedling transplantation. Based on the mechanical properties of pepper stem, a clamping mechanism wit...
Contact between Prefabricated Pile and Pile Clamping Jaws under Pile Driving
Contact between Prefabricated Pile and Pile Clamping Jaws under Pile Driving
Pile clamping mechanism with hydraulic static pile driver has advantages of convenient for the design, improvement and use. The maximum transmission pile driving force of pile clam...
Improvement of Based Sector and Comparison Speed and Electromagnetic Torque of Direct Torque Control
Improvement of Based Sector and Comparison Speed and Electromagnetic Torque of Direct Torque Control
Direct torque control is one type of vector control used to operate an induction motor. Efficient control rules for induction motor drives offer a great chance to save energy. In c...
Research on Calculation Method of Characteristic Torque of Prestressed UHPC-RC I-Shaped Composite Beam
Research on Calculation Method of Characteristic Torque of Prestressed UHPC-RC I-Shaped Composite Beam
The prestressed UHPC-RC I-shaped composite beam is a common new type of beam structure at present, and there is relatively little research on the torsional calculation method for t...
Correlation study of changes in visual acuity, pupil diameter, Kappa angle, and Alpha angle after phacoemulsification surgery combined with multifocal IOL implantation
Correlation study of changes in visual acuity, pupil diameter, Kappa angle, and Alpha angle after phacoemulsification surgery combined with multifocal IOL implantation
Abstract
Purpose To study the changes and correlation of visual acuity, pupil size, kappa angle and Alpha angle after phacoemulsification combined with multifocal intraocul...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Effect of torque ratio on speed regulating start
Effect of torque ratio on speed regulating start
Purpose
Friction pairs of the hydro-viscous drive speed regulating start device should be designed based on the rated torque. To obtain design basis of the rated torque of the hydr...
Research on peripheral clamping of large-aperture laser transport mirror
Research on peripheral clamping of large-aperture laser transport mirror
This article introduces the study of peripheral clamping for large-aperture laser mirrors in high power laser facilities. Some multi-point clamping schemes were experimentally test...

