Javascript must be enabled to continue!
What is the impact of head movement on automated CT perfusion mismatch evaluation in acute ischemic stroke?
View through CrossRef
ObjectivesAutomated CT perfusion mismatch assessment is an established treatment decision tool in acute ischemic stroke. However, the reliability of this method in patients with head motion is unclear. We therefore sought to evaluate the influence of head movement on automated CT perfusion mismatch evaluation.MethodsUsing a realistic CT brain-perfusion-phantom, 7 perfusion mismatch scenarios were simulated within the left middle cerebral artery territory. Real CT noise and artificial head movement were added. Thereafter, ischemic core, penumbra volumes and mismatch ratios were evaluated using an automated mismatch analysis software (RAPID, iSchemaView) and compared with ground truth simulated values.ResultsWhile CT scanner noise alone had only a minor impact on mismatch evaluation, a tendency towards smaller infarct core estimates (mean difference of −5.3 (−14 to 3.5) mL for subtle head movement and −7.0 (−14.7 to 0.7) mL for strong head movement), larger penumbral estimates (+9.9 (−25 to 44) mL and +35 (−14 to 85) mL, respectively) and consequently larger mismatch ratios (+0.8 (−1.5 to 3.0) for subtle head movement and +1.9 (−1.3 to 5.1) for strong head movement) were noted in dependence of patient head movement.ConclusionsMotion during CT perfusion acquisition influences automated mismatch evaluation. Potentially treatment-relevant changes in mismatch classifications in dependence of head movement were observed and occurred in favor of mechanical thrombectomy.
Title: What is the impact of head movement on automated CT perfusion mismatch evaluation in acute ischemic stroke?
Description:
ObjectivesAutomated CT perfusion mismatch assessment is an established treatment decision tool in acute ischemic stroke.
However, the reliability of this method in patients with head motion is unclear.
We therefore sought to evaluate the influence of head movement on automated CT perfusion mismatch evaluation.
MethodsUsing a realistic CT brain-perfusion-phantom, 7 perfusion mismatch scenarios were simulated within the left middle cerebral artery territory.
Real CT noise and artificial head movement were added.
Thereafter, ischemic core, penumbra volumes and mismatch ratios were evaluated using an automated mismatch analysis software (RAPID, iSchemaView) and compared with ground truth simulated values.
ResultsWhile CT scanner noise alone had only a minor impact on mismatch evaluation, a tendency towards smaller infarct core estimates (mean difference of −5.
3 (−14 to 3.
5) mL for subtle head movement and −7.
0 (−14.
7 to 0.
7) mL for strong head movement), larger penumbral estimates (+9.
9 (−25 to 44) mL and +35 (−14 to 85) mL, respectively) and consequently larger mismatch ratios (+0.
8 (−1.
5 to 3.
0) for subtle head movement and +1.
9 (−1.
3 to 5.
1) for strong head movement) were noted in dependence of patient head movement.
ConclusionsMotion during CT perfusion acquisition influences automated mismatch evaluation.
Potentially treatment-relevant changes in mismatch classifications in dependence of head movement were observed and occurred in favor of mechanical thrombectomy.
Related Results
Iranian stroke model-how to involve health policymakers
Iranian stroke model-how to involve health policymakers
Stroke in Iran, with more than 83 million population, is a leading cause of disability and mortality in adults. Stroke has higher incidence in Iran comparing the global situation a...
Comparative Characterization of Candidate Molecular Markers in Ischemic and Hemorrhagic Stroke
Comparative Characterization of Candidate Molecular Markers in Ischemic and Hemorrhagic Stroke
According to epidemiological studies, the leading cause of morbidity, disability and mortality are cerebrovascular diseases, in particular ischemic and hemorrhagic strokes. In rece...
Prevalence of Diabetes Mellitus in Acute Ischemic Stroke Patients at Tertiary Care Hospital
Prevalence of Diabetes Mellitus in Acute Ischemic Stroke Patients at Tertiary Care Hospital
Back ground: The third largest cause of death around the globe is stroke. In the United States the largest cause of disability is also stroke. For stroke and coronary heart diseas...
Abstract TP294: The Impact of Chronic Kidney Disease Severity on Incident Acute Ischemic Stroke
Abstract TP294: The Impact of Chronic Kidney Disease Severity on Incident Acute Ischemic Stroke
Introduction:
Chronic kidney disease (CKD) and ischemic stroke are both associated with significant global disease burdens and share common risk factors. Understanding ...
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
Hypertension, Age, Sex, and Stroke Incidence In Stroke Installation Room RSUD dr. M. Yunus BengkuluABSTRAKStroke adalah gejala-gejala defisit fungsi susunan saraf yang diakibatka...
Clinical Features, Risk Factors and Hospital Mortality of Acute Stroke Patients
Clinical Features, Risk Factors and Hospital Mortality of Acute Stroke Patients
Background: Stroke is a leading cause of mortality and disability worldwide. To prevent complications and permanent defects, early diagnosis, distinguishing the type and risk facto...
Harmonizing and Optimizing CT Perfusion Stroke Imaging
Harmonizing and Optimizing CT Perfusion Stroke Imaging
This thesis focuses on harmonizing and optimizing CT perfusion (CTP) imaging for stroke. CTP imaging can help select patients with ischemic stroke for thrombectomy. However, due to...
Systematic Review of Existing Stroke Guidelines: Case for a Change
Systematic Review of Existing Stroke Guidelines: Case for a Change
Background and Purpose.
Stroke represents one of the most important causes of morbidity (Just over hundred million patients with disabling of ongoing effects of...

