Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature

View through CrossRef
Introduction: One of the popular treatment strategies for complex cerebral aneurysms with wide necks or low dome-to-neck ratios is stent-assisted coiling. The most widely used intracranial stents for stent-assisted coiling are Neuroform (NF) and Enterprise (EP) stents. The purposes of this study are to review the recent literature of the past 5 years to compare outcomes between the EP and NF stent-assist coiling systems so as to comment on the safety, efficacy, complications, and recurrence rate of stent-assisted coiling in general. Methods: PubMed was used to search for all published literature of NF or EP stent-assisted coiling of unruptured cerebral aneurysms from January 2014 to August 2019 with the search terms of “Enterprise stent-assisted coiling,” “Neuroform stent,” and “Neuroform vs. Enterprise stent.” Results: Twenty two publications met the inclusion criteria which encompass 1764 patients and 1873 aneurysms. Out of these 1873 aneurysms, 1007 aneurysms were treated with EP stent and 866 aneurysms were treated with NF stent. The overall outcome was low rates of thromboembolic complications (4.37%) and intracranial hemorrhage (1.13%), low permanent morbidity (1.70%) and mortality (0.40%), and lower rate of recanalization (11%). Data analysis shows an overall higher rate of complication and recurrence of aneurysm and lower overall rate of aneurysmal occlusion in the patients where EP stent was used in comparison to NF stent. However, this difference was not statistically significant. Conclusions: The review of two stent-assisted coiling devices using EP and NF stents including 1873 aneurysms in 1764 patients revealed that overall, it is safe and effective with comparable outcomes.
Title: Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature
Description:
Introduction: One of the popular treatment strategies for complex cerebral aneurysms with wide necks or low dome-to-neck ratios is stent-assisted coiling.
The most widely used intracranial stents for stent-assisted coiling are Neuroform (NF) and Enterprise (EP) stents.
The purposes of this study are to review the recent literature of the past 5 years to compare outcomes between the EP and NF stent-assist coiling systems so as to comment on the safety, efficacy, complications, and recurrence rate of stent-assisted coiling in general.
Methods: PubMed was used to search for all published literature of NF or EP stent-assisted coiling of unruptured cerebral aneurysms from January 2014 to August 2019 with the search terms of “Enterprise stent-assisted coiling,” “Neuroform stent,” and “Neuroform vs.
Enterprise stent.
” Results: Twenty two publications met the inclusion criteria which encompass 1764 patients and 1873 aneurysms.
Out of these 1873 aneurysms, 1007 aneurysms were treated with EP stent and 866 aneurysms were treated with NF stent.
The overall outcome was low rates of thromboembolic complications (4.
37%) and intracranial hemorrhage (1.
13%), low permanent morbidity (1.
70%) and mortality (0.
40%), and lower rate of recanalization (11%).
Data analysis shows an overall higher rate of complication and recurrence of aneurysm and lower overall rate of aneurysmal occlusion in the patients where EP stent was used in comparison to NF stent.
However, this difference was not statistically significant.
Conclusions: The review of two stent-assisted coiling devices using EP and NF stents including 1873 aneurysms in 1764 patients revealed that overall, it is safe and effective with comparable outcomes.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Outcome evaluation of flow diverter stent placement in treatment of ruptured and unruptured cerebral aneurysms
Outcome evaluation of flow diverter stent placement in treatment of ruptured and unruptured cerebral aneurysms
Background: Cerebral aneurysms affect about 5% of the population and are associated with high mortality rates and severe complications for families and society. Complex aneurysm ty...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Abstract Introduction In patients with 70% to 99% diameter carotid artery stenosis cerebral blood flow reserve may be protectiv...
Aortic endograft and bridging stent-graft remodeling after branched endovascular aortic repair
Aortic endograft and bridging stent-graft remodeling after branched endovascular aortic repair
Objectives The results of branched endovascular repair of thoracoabdominal aneurysms are mainly dependent on durability of the graft used. The purpose of this study was to evaluate...

Back to Top