Javascript must be enabled to continue!
In vivo O‐Space imaging with a dedicated 12 cmZ2 insert coil on a human 3T scanner using phase map calibration
View through CrossRef
AbstractRecently, spatial encoding with nonlinear magnetic fields has drawn attention for its potential to achieve faster gradient switching within safety limits, tailored resolution in regions of interest, and improved parallel imaging using encoding fields that complement the sensitivity profiles of radio frequency receive arrays. Proposed methods can broadly be divided into those that use phase encoding (Cartesian‐trajectory PatLoc and COGNAC) and those that acquire nonlinear projections (O‐Space, Null space imaging, radial PatLoc, and 4D‐RIO). Nonlinear projection data are most often reconstructed with iterative algorithms that backproject data using the full encoding matrix. Just like conventional radial sequences that use linear spatial encoding magnetic fields, nonlinear projection methods are more sensitive than phase encoding methods to imperfect calibration of the encoding fields. In this work, voxel‐wise phase evolution is mapped at each acquired point in an O‐Space trajectory using a variant of chemical shift imaging, capturing all spin dynamics caused by encoding fields, eddy currents, and pulse timing. Phase map calibration is then applied to data acquired from a high‐power, 12 cm,Z2 insert coil with an eight‐channel radio frequency transmit‐receive array on a 3T human scanner. We show the first experimental proof‐of‐concept O‐Space images on in vivo and phantom samples, paving the way for more in‐depth exploration of O‐Space and similar imaging methods. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Title: In vivo O‐Space imaging with a dedicated 12 cmZ2 insert coil on a human 3T scanner using phase map calibration
Description:
AbstractRecently, spatial encoding with nonlinear magnetic fields has drawn attention for its potential to achieve faster gradient switching within safety limits, tailored resolution in regions of interest, and improved parallel imaging using encoding fields that complement the sensitivity profiles of radio frequency receive arrays.
Proposed methods can broadly be divided into those that use phase encoding (Cartesian‐trajectory PatLoc and COGNAC) and those that acquire nonlinear projections (O‐Space, Null space imaging, radial PatLoc, and 4D‐RIO).
Nonlinear projection data are most often reconstructed with iterative algorithms that backproject data using the full encoding matrix.
Just like conventional radial sequences that use linear spatial encoding magnetic fields, nonlinear projection methods are more sensitive than phase encoding methods to imperfect calibration of the encoding fields.
In this work, voxel‐wise phase evolution is mapped at each acquired point in an O‐Space trajectory using a variant of chemical shift imaging, capturing all spin dynamics caused by encoding fields, eddy currents, and pulse timing.
Phase map calibration is then applied to data acquired from a high‐power, 12 cm,Z2 insert coil with an eight‐channel radio frequency transmit‐receive array on a 3T human scanner.
We show the first experimental proof‐of‐concept O‐Space images on in vivo and phantom samples, paving the way for more in‐depth exploration of O‐Space and similar imaging methods.
Magn Reson Med, 2013.
© 2012 Wiley Periodicals, Inc.
Related Results
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
The design of magnetic resonance imaging (MRI) radiofrequency (RF) coils plays a critical role in determining image quality, with signal-to-noise ratio (SNR) and contrast-to-noise ...
MRI Scanner Vibration and Acoustic Noise
MRI Scanner Vibration and Acoustic Noise
To characterize the vibration properties as well as the acoustic noise properties of the gradient coil, a finite element (FE) model was developed using the dimensional design speci...
Current control and tuning in a closed HTS coil
Current control and tuning in a closed HTS coil
Up to today, a coil made of high temperature superconductor (HTS) usually needs a soldered joint to form a closed circuit. It is very difficult to have the joint fully superconduct...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Seditious Spaces
Seditious Spaces
The title ‘Seditious Spaces’ is derived from one aspect of Britain’s colonial legacy in Malaysia (formerly Malaya): the Sedition Act 1948. While colonial rule may seem like it was ...
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Using coil antennae as transmitter and receiver to develop a geosteering tool, one has to increase the spacing between the transmitter and receiver to detect formation boundaries f...
Design 3D Printed Coils for WPT
Design 3D Printed Coils for WPT
Abstract
The geometric shapes of coils influence the performance of a 3D IPT system. In this paper, we proposed a 3D coil design method based on (3D) printing electr...
Résumés des conférences JRANF 2021
Résumés des conférences JRANF 2021
able des matières
Résumés. 140
Agenda Formation en Radioprotection JRANF 2021 Ouagadougou. 140
RPF 1 Rappel des unités de doses. 140
RPF 2 Risques déterministes et stochastique...

