Javascript must be enabled to continue!
Effect of anisotropy on stress-induced electrical potentials in bovine bone using ultrasound irradiation
View through CrossRef
The bone fracture healing mechanism of the low-intensity pulsed ultrasound technique is not yet clearly understood. In our previous study, the electrical potentials induced in bone were successfully measured by focusing on piezoelectricity in the MHz range. Bone is composed of collagen and hydroxyapatite and has strong anisotropy. The purpose of this study is to investigate the effects of bone anisotropy on the electrical potentials induced by ultrasound irradiation. For this study, ultrasound bone transducers were fabricated using cortical bovine bone plates as piezoelectric devices. An ultrasound of 7.4 kPapeak-peak (i.e., the peak-to-peak pressure value) was used to irradiate the side surface of each bone plate. Electrical potentials induced in the bone plate were then measured by varying the wave propagation direction in the plate. The peak-to-peak values of these ultrasonically induced electrical potentials were found to vary with changes in the ultrasound propagation direction in the bone sample. The potential was maximized at an inclination of approximately 45° to the bone axis but was minimized around the three orthogonal directions. These maxima and minima ranged from 28 to 33 μVpeak-peak and from 5 to 12 μVpeak-peak, respectively. Additionally, our ultrasound results indicated a change in polarity due to bone anisotropy in the MHz range.
Title: Effect of anisotropy on stress-induced electrical potentials in bovine bone using ultrasound irradiation
Description:
The bone fracture healing mechanism of the low-intensity pulsed ultrasound technique is not yet clearly understood.
In our previous study, the electrical potentials induced in bone were successfully measured by focusing on piezoelectricity in the MHz range.
Bone is composed of collagen and hydroxyapatite and has strong anisotropy.
The purpose of this study is to investigate the effects of bone anisotropy on the electrical potentials induced by ultrasound irradiation.
For this study, ultrasound bone transducers were fabricated using cortical bovine bone plates as piezoelectric devices.
An ultrasound of 7.
4 kPapeak-peak (i.
e.
, the peak-to-peak pressure value) was used to irradiate the side surface of each bone plate.
Electrical potentials induced in the bone plate were then measured by varying the wave propagation direction in the plate.
The peak-to-peak values of these ultrasonically induced electrical potentials were found to vary with changes in the ultrasound propagation direction in the bone sample.
The potential was maximized at an inclination of approximately 45° to the bone axis but was minimized around the three orthogonal directions.
These maxima and minima ranged from 28 to 33 μVpeak-peak and from 5 to 12 μVpeak-peak, respectively.
Additionally, our ultrasound results indicated a change in polarity due to bone anisotropy in the MHz range.
Related Results
Ultrasonically-induced electrical potentials in demineralized bovine cortical bone
Ultrasonically-induced electrical potentials in demineralized bovine cortical bone
While the low-intensity pulsed ultrasound technique has proved useful for healing of bone fractures, the ultrasound healing mechanism is not yet understood. To understand the initi...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 BMPs identified to da...
Study on Ultrasound Irradiation Induction of Electrical Potentials in Bone
Study on Ultrasound Irradiation Induction of Electrical Potentials in Bone
Objective:
It is well known that applied stress induces electrical potentials in bone. We have experimentally studied whether induced potentials could be found in bone ...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract
Introduction
Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
ANISOTROPY QUANTIFICATION USING HIGH-RESOLUTION WHOLE-CORE CT-SCAN IMAGES
ANISOTROPY QUANTIFICATION USING HIGH-RESOLUTION WHOLE-CORE CT-SCAN IMAGES
Spatial anisotropy and heterogeneity in petrophysical properties can significantly affect formation evaluation of hydrocarbon bearing formations. A common example is permeability a...
Piezoelectric response of bone in the MHz range
Piezoelectric response of bone in the MHz range
The healing mechanism of bone fractures by low intensity ultrasound is not yet to be fully understood. As one possible initial process of this mechanism, we focus on the piezoelect...
Effects of microstructure and water on the electrical potentials in bone induced by ultrasound irradiation
Effects of microstructure and water on the electrical potentials in bone induced by ultrasound irradiation
The healing mechanism of bone fractures by low intensity pulse ultrasound is yet to be fully understood. There have been many discussions regarding how the high frequency dynamic s...