A-171 Novel Fluorometric Assay for Pediatric Anti-Factor Xa Testing: Minimizing Bilirubin and Hemolysis Interference in Whole Blood

View through CrossRef
Abstract Background High bilirubin levels are common in pediatric patients and are noted in patients undergoing extracorporeal membrane oxygenation (ECMO). Acute anticoagulation therapy necessitates frequent monitoring of anti-Factor Xa activity (aFXa), and high bilirubin levels cause interference in chromogenic assays. Moreover, large volumes of blood lead to iatrogenic anemia in pediatric and neonatal patients. We developed a fluorescence assay to measure aFXa activity on a near-patient digital microfluidic (DMF) platform using low volume whole blood samples (< 50 μL) and present the results of interference of bilirubin and hemolysis on aFXa activity. Methods aFXa assay was performed on a DMF cartridge wherein 50 μL whole blood was loaded into the cartridge which separates plasma droplets through agglutination within the cartridge followed by incubation with a droplet containing exogenous FXa and a fluorogenic substrate. The fluorescence is inversely proportional to the concentration of heparin in the sample. All required reagents for the aFXa assay are dried within the cartridge, allowing for integrated sample preparation and assay automation for point of care use. To test the interference of bilirubin, we spiked into whole blood different concentrations of unconjugated bilirubin, ranging from 0-40 mg/dL. We also tested hemoglobin interference by testing 4 different concentrations of hemolysate (0-1,000 mg/dL) on the aFXa assay. All experiments were performed with 6 replicates of each concentration. Results Across each bilirubin concentration, we saw uniform measurements of aFXa activity (see Table). We observed < 5% CV in aFXa activity with 0, 13.33 and 26.67 mg/dL bilirubin levels. All measured unfractionated heparin values for hemolysate interference were <5% CV. Conclusions Our interference results suggest that high bilirubin and hemolysate levels do not interfere with our novel aFXa fluorescence assay. Further clinical studies are underway to establish clinical performance.
Title: A-171 Novel Fluorometric Assay for Pediatric Anti-Factor Xa Testing: Minimizing Bilirubin and Hemolysis Interference in Whole Blood
Description:
Abstract Background High bilirubin levels are common in pediatric patients and are noted in patients undergoing extracorporeal membrane oxygenation (ECMO).
Acute anticoagulation therapy necessitates frequent monitoring of anti-Factor Xa activity (aFXa), and high bilirubin levels cause interference in chromogenic assays.
Moreover, large volumes of blood lead to iatrogenic anemia in pediatric and neonatal patients.
We developed a fluorescence assay to measure aFXa activity on a near-patient digital microfluidic (DMF) platform using low volume whole blood samples (< 50 μL) and present the results of interference of bilirubin and hemolysis on aFXa activity.
Methods aFXa assay was performed on a DMF cartridge wherein 50 μL whole blood was loaded into the cartridge which separates plasma droplets through agglutination within the cartridge followed by incubation with a droplet containing exogenous FXa and a fluorogenic substrate.
The fluorescence is inversely proportional to the concentration of heparin in the sample.
All required reagents for the aFXa assay are dried within the cartridge, allowing for integrated sample preparation and assay automation for point of care use.
To test the interference of bilirubin, we spiked into whole blood different concentrations of unconjugated bilirubin, ranging from 0-40 mg/dL.
We also tested hemoglobin interference by testing 4 different concentrations of hemolysate (0-1,000 mg/dL) on the aFXa assay.
All experiments were performed with 6 replicates of each concentration.
Results Across each bilirubin concentration, we saw uniform measurements of aFXa activity (see Table).
We observed < 5% CV in aFXa activity with 0, 13.
33 and 26.
67 mg/dL bilirubin levels.
All measured unfractionated heparin values for hemolysate interference were <5% CV.
Conclusions Our interference results suggest that high bilirubin and hemolysate levels do not interfere with our novel aFXa fluorescence assay.
Further clinical studies are underway to establish clinical performance.

Related Results

[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Abstract Background:To explore whether there is abnormality of neonatal brains’ MRI and BAEP with different bilirubin levels, and to provide an objective basis for early di...
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Abstract Background:To explore whether there is abnormality of neonatal brains’ MRI and BAEP with different bilirubin levels, and to provide an objective basis for early di...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract  Introduction Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
BACKGROUND: A workforce analysis was conducted to predict whether the projected future supply of pediatric anesthesiologists is balanced with the requirements of the in...
Inhibition of the Complement Alternative Pathway Attenuates Hemolysis and Preserves Renal Function in a Mouse Model of Sickle Cell Disease
Inhibition of the Complement Alternative Pathway Attenuates Hemolysis and Preserves Renal Function in a Mouse Model of Sickle Cell Disease
Introduction: the alternative pathway (AP) of complement activation plays a significant role in the pathophysiology of sickle cell disease (SCD), contributing to hemolysis and subs...
Modification of the MTT method for the study of bilirubin cytotoxicity
Modification of the MTT method for the study of bilirubin cytotoxicity
Abstract Background : We propose a modification of the MTT [3‐(4,5‐dimethylthiazol‐2‐yl)‐2,5‐diphenyltetrazolium bromide] method to study the cytotoxicity o...
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
BACKGROUND: The geographic relationship between pediatric anesthesiologists and the pediatric population has potentially important clinical and policy implications. In ...

Back to Top